• No results found

Graphite furnace atomic absorption

Determination of Plantinum in Rocks by Graphite Furnace Atomic Absorption Spectrometry After Separation on Sorbent

Determination of Plantinum in Rocks by Graphite Furnace Atomic Absorption Spectrometry After Separation on Sorbent

... 800 Graphite Furnace Atomic Absorption spectroscopy (GFAAS) excites a enrichment liquid sample in a small graphite tube allowing a very low range analysis of platinum in solution, in ...

5

Validation of a method for direct cadmium determination in breast milk by graphite furnace atomic absorption spectrometry using tantalum treated graphite tube and co injection of iridium as chemical modifier

Validation of a method for direct cadmium determination in breast milk by graphite furnace atomic absorption spectrometry using tantalum treated graphite tube and co injection of iridium as chemical modifier

... A method for direct cadmium determination in breast milk by graphite furnace atomic absorption spectrometry (GF AAS) was developed in this work. Twenty six experiments were conducted for ...

6

Optimization of Chromium, Nickel and Vanadium analysis in crude oil using graphite furnace atomic absorption spectroscopy

Optimization of Chromium, Nickel and Vanadium analysis in crude oil using graphite furnace atomic absorption spectroscopy

... 37. Vale, M. G. R., Damina, I. C. F., Klassena, A., Silvaa, M. M., Welzb, B., Silvab, A. F., Leprib, F. G., Borgesb, D. L. G. and Heitmann, U. Method Development for the Determination of Nickel in Petroleum Using ...

24

Dealing with Outlier in Linear Calibration Curves: A Case Study of Graphite Furnace Atomic Absorption Spectrometry

Dealing with Outlier in Linear Calibration Curves: A Case Study of Graphite Furnace Atomic Absorption Spectrometry

... Abstract: Outlier in the calibration of lead by graphite furnace atomic absorption spectrometry (GF-AAS) has been studied with help of the statistical tool F-test and T-test. The process ...

7

Investigation of Distribution for Trace Lead and Cadmium in Chinese Herbal Medicines and Their Decoctions by Graphite Furnace Atomic Absorption Spectrometry

Investigation of Distribution for Trace Lead and Cadmium in Chinese Herbal Medicines and Their Decoctions by Graphite Furnace Atomic Absorption Spectrometry

... Lead and cadmium in herbal medicines are highly toxic to living organisms even in low concentrations. An effective method is developed for analysis of trace lead and cadmium in Chinese herbal medicines and their ...

6

Study on the effects of nitrilotriproprionic acid and 4,5-dihydroxy-1,3-benzene disulphonate on the fractionation of beryllium in human serum using graphite furnace atomic absorption spectrometry

Study on the effects of nitrilotriproprionic acid and 4,5-dihydroxy-1,3-benzene disulphonate on the fractionation of beryllium in human serum using graphite furnace atomic absorption spectrometry

... samples were left to equilibrate for two hours. A 2 mL aliquot of each sub-sample was transferred to a Centricon centrifugal device with ultracel YM-10 (10,000 MWCO) (Millipore Corporation, Ireland) and centrifuged at ...

9

Determination of Lead in Mashhad City Tap Water by Graphite Furnace Atomic Absorption Spectrometry

Determination of Lead in Mashhad City Tap Water by Graphite Furnace Atomic Absorption Spectrometry

... The tap water in Mashhad is provided from two rivers and 300 wells in margins of city. There are different ways that lead can enter the drinking water, such as from drinking water well contamination of industrial and ...

8

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

Air-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples

... A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt(II) and nickel(II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) ...

12

Measuring Conditions for the Determination of Lead in Iron Matrix Samples Using Graphite Atomizers with/without a Platform in Graphite Furnace Atomic Absorption Spectrometry

Measuring Conditions for the Determination of Lead in Iron Matrix Samples Using Graphite Atomizers with/without a Platform in Graphite Furnace Atomic Absorption Spectrometry

... In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when ...

8

Graphite furnace atomic absorption spectrometry as a routine method for the quantification of beryllium in blood and serum

Graphite furnace atomic absorption spectrometry as a routine method for the quantification of beryllium in blood and serum

... increased research efforts are being targeted towards the development of a CBD treatment by chelation therapy [7,8]. For that purpose, a routine method is required to analyse beryllium in micro samples of biological ...

8

Determination of Trace Amounts of Lead by Modified Graphite Furnace Atomic Absorption Spectrometry after Liquid Phase Microextraction with Pyrimidine 2 thiol

Determination of Trace Amounts of Lead by Modified Graphite Furnace Atomic Absorption Spectrometry after Liquid Phase Microextraction with Pyrimidine 2 thiol

... AA-6300G atomic absorption spec- trometer (Kyoto, Japan) with GFA-EX7i graphite furnace atomizer and D2 lamp for background correction was ...

11

Degradation Process of Graphite Furnace Estimated from the Atomic Gas Temperature of Iron in Graphite Furnace Atomic Absorption Spectrometry

Degradation Process of Graphite Furnace Estimated from the Atomic Gas Temperature of Iron in Graphite Furnace Atomic Absorption Spectrometry

... an atomic gas to measure the atomic ...atomization furnace; as the result, it is generally lower compared with the other analysis method, such as inductively coupled plasma-optical emission spec- ...

5

Quantification of gallium, indium and thallium in meteorites and other geological materials by graphite furnace atomic absorption spectrometry : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy at Massey

Quantification of gallium, indium and thallium in meteorites and other geological materials by graphite furnace atomic absorption spectrometry : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy at Massey University

... Hydride - Generat ion Atomic Abs orpt ion Spectrometry for the Quant i f ication of Germa nium in Iron Meteor ites An al.. Separation of I ron from I nd ium with Cupf erron Proc..[r] ...

203

Determination of Heavy Metals at Sub ppb Levels in Water by Graphite Furnace Atomic Absorption Spectrometry Using a Direct Introduction Technique after Preconcentration with an Iminodiacetate Extraction Disk

Determination of Heavy Metals at Sub ppb Levels in Water by Graphite Furnace Atomic Absorption Spectrometry Using a Direct Introduction Technique after Preconcentration with an Iminodiacetate Extraction Disk

... background absorption caused by the evolution of smoke may be observed during the ato- mization ...the furnace, the absorbance-time profiles of Pb and Bi showed a single broad peak, as shown in Figure ...

10

Effervescence-assisted Dispersive Liquid-liquid Microextraction for Trace Analysis of Co(II) and Ni(II) from Aqueous Sample Based on Phthalic Acid as a Complexing agent and Co-disperser

Effervescence-assisted Dispersive Liquid-liquid Microextraction for Trace Analysis of Co(II) and Ni(II) from Aqueous Sample Based on Phthalic Acid as a Complexing agent and Co-disperser

... with graphite furnace atomic absorption spectrometry has been developed for the extraction and preconcentration of Co(II) and Ni(II) from aqueous ...

16

Atomic absorption spectrometry in wine analysis

Atomic absorption spectrometry in wine analysis

... the graphite furnace and suitable calibration method are the most popular topics of investiga- ...nonspecific absorption and ethanol content in wine sample which impairs sample de- livery into the ...

15

Cr (VI)/Cr (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY

Cr (VI)/Cr (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY

... pyrolytic graphite furnace ...Pd-coated graphite furnace tube in higher deposition potential which both AA measurements could be used for speciation of Cr (VI)/Cr (III) in salt ...

6

DEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE

DEVELOPMENT OF A METHOD FOR ALUMINIUM DETERMINATION IN SERUM AND DIALYSIS FLUID BY FLAMELESS ATOMIC ABSORPTION WITH GRAPHITE FURNACE

... the absorption signals obtained from fresh sera and water samples with those obtained from samples held in the containers (data not shown), The temperature stages used led to the complete atomization of aluminium ...

5

Qualification of Atomic Absorption Spectrometer in Prospective View of Pharmaceutical Analysis

Qualification of Atomic Absorption Spectrometer in Prospective View of Pharmaceutical Analysis

... AAS was qualified as per pharmacopoeia requirements. Copper, manganese, mercury and cad- mium hallow cathode lamps were used for qualification purposes. Design qualification and instal- lation qualification met the ...

8

Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption

Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption

... effective atomic number of human tissues and dosimeters is ...effective atomic numbers of some pure thermoluminescent dosimetric compounds have been calculated with the interpolation method ...

5

Show all 9846 documents...

Related subjects