• No results found

hemodynamic characteristics

Angioarchitectures and Hemodynamic Characteristics of Posterior Communicating Artery Aneurysms and Their Association with Rupture Status

Angioarchitectures and Hemodynamic Characteristics of Posterior Communicating Artery Aneurysms and Their Association with Rupture Status

... Hemodynamic Characteristics Associated with Rupture Results of the association between hemodynamic variables and aneurysm rupture are presented in Table ...

8

Numerical Analysis on the Effect of Normotensive and Hypertensive Physiological Conditions onto Hemodynamic Characteristics in Stented Carotid Artery

Numerical Analysis on the Effect of Normotensive and Hypertensive Physiological Conditions onto Hemodynamic Characteristics in Stented Carotid Artery

... of hemodynamic characteristics may vary when studied on patient-specific ...the hemodynamic characteristic due to stent geometry and blood physiological condition without any other influence ...

14

Influence of Parent Artery Segmentation and Boundary Conditions on Hemodynamic Characteristics of Intracranial Aneurysms

Influence of Parent Artery Segmentation and Boundary Conditions on Hemodynamic Characteristics of Intracranial Aneurysms

... the hemodynamic behaviors, there- fore, the variation tendency among each simulation case is considered more important than the values for the hemodyna- mic factors ...CFD hemodynamic analy- ...

10

A geometric scaling model for assessing the impact of aneurysm size ratio on hemodynamic characteristics

A geometric scaling model for assessing the impact of aneurysm size ratio on hemodynamic characteristics

... The morphological parameters (e.g. shape, size and location) have been proved to have impacts on the hemodynamic characteristics in IAs, which can be further used for the prediction of IA rupture risk [8]. ...

14

Association of Hemodynamic Characteristics and Cerebral Aneurysm Rupture

Association of Hemodynamic Characteristics and Cerebral Aneurysm Rupture

... of hemodynamic variables, we proposed a qualitative characterization of aneurysmal flows based on observations of gross flow features and we investigated possible relationships with aneurysm ...qualitative ...

7

Hemodynamic Characteristics of Ruptured and Unruptured Multiple Aneurysms at Mirror and Ipsilateral Locations

Hemodynamic Characteristics of Ruptured and Unruptured Multiple Aneurysms at Mirror and Ipsilateral Locations

... whether hemodynamic characteristics of the ruptured aneurysm in patients with multiple aneurysms were dif- ferent from those of unruptured aneurysms in the same ...identify hemodynamic factors that ...

7

Erythrocytes in sickle cell anemia are heterogeneous in their rheological and hemodynamic characteristics

Erythrocytes in sickle cell anemia are heterogeneous in their rheological and hemodynamic characteristics

... and hemodynamic characteristics of four major classes of hemoglobin SS ...the hemodynamic studies were performed on the isolated, artificially perfused mesoappendix vasculature of the rat (Baez ...

11

Colour Doppler ultrasound hemodynamic characteristics of patients with priapism before and after therapeutic interventions

Colour Doppler ultrasound hemodynamic characteristics of patients with priapism before and after therapeutic interventions

... veno-occlusive hemodynamic characteristics in CDU ...CDU hemodynamic pattern showed primarily an arteriogenic status, we would observe the patients rather than carrying out further shunt surgery ...

8

Computational analysis of the hemodynamic characteristics under interaction influence of β-blocker and LVAD

Computational analysis of the hemodynamic characteristics under interaction influence of β-blocker and LVAD

... the hemodynamic effect of LVAD with β-blocker on the car- diovascular ...the hemodynamic effect of LVAD with or with- out β-blocker on the cardiovascular system has been reviewed by using a multi-scale ...

17

Differences in Morphologic and Hemodynamic Characteristics for “PHASES Based” Intracranial Aneurysm Locations

Differences in Morphologic and Hemodynamic Characteristics for “PHASES Based” Intracranial Aneurysm Locations

... Previous studies have suggested a significant association between IA location and risk of rupture. In this study, we analyzed 311 aneurysm cases from our center and compared the differences in morphologic and ...

6

Hemodynamic and Morphological Analysis of Mirror Aneurysms Prior to Rupture

<p>Hemodynamic and Morphological Analysis of Mirror Aneurysms Prior to Rupture</p>

... the hemodynamic characteristics by adopting the MANs model, we might achieve more reasonable ...provides hemodynamic and morpho- logical analysis using twelve rare MANs prior to rupture, eliminating ...

9

Analysis of Morphologic and Hemodynamic Parameters for Unruptured Posterior Communicating Artery Aneurysms with Oculomotor Nerve Palsy

Analysis of Morphologic and Hemodynamic Parameters for Unruptured Posterior Communicating Artery Aneurysms with Oculomotor Nerve Palsy

... and hemodynamic parameters revealed that unruptured PcomA aneurysms with oculomotor nerve palsy had almost the same morphologic and hemodynamic characteristics as that of ruptured ...

5

Functional hemodynamic monitoring

Functional hemodynamic monitoring

... of hemodynamic variables often suggest cardiogenic, hypovolemic, obstructive, or distributive (septic) etiologies to cardiovascular insufficiency, thus defining the specific treatments ...Solitary ...

7

Clinical correlates of chronic cerebrospinal venous insufficiency in multiple sclerosis

Clinical correlates of chronic cerebrospinal venous insufficiency in multiple sclerosis

... Although our large prevalence study showed higher fre- quency of CSSVI in progressive MS compared to relapsing MS, we did not obtain evidence for significant associations with disability. The divergence of the prevalence ...

6

Tolvaptan: the evidence for its therapeutic value in acute heart failure syndrome

Tolvaptan: the evidence for its therapeutic value in acute heart failure syndrome

... acute hemodynamic effects of tolvaptan in AHFS were carefully evaluated in the Effect of Tolvaptan on Hemodynamic Parameters in Subjects with Heart Failure (ECLIPSE) trial, in which 180 patients with stable ...

13

Persistently high venous to arterial carbon dioxide differences during early resuscitation are associated with poor outcomes in septic shock

Persistently high venous to arterial carbon dioxide differences during early resuscitation are associated with poor outcomes in septic shock

... systemic hemodynamic parameters does not guarantee adequate tissue perfusion [5-7], and in fact a substantial number of patients still progress to multiorgan dysfunction and death despite meeting ScvO 2 targets ...

10

How Do Coil Configuration and Packing Density Influence Intra Aneurysmal Hemodynamics?

How Do Coil Configuration and Packing Density Influence Intra Aneurysmal Hemodynamics?

... We have studied the influence of coiling treatment on intra- aneurysmal hemodynamics in 3 patient-specific aneurysm ge- ometries by using a virtual coiling technique and CFD model- ing. Four main findings were extracted ...

7

A prospective, randomized study to assess the effect of pneumoperitoneum on arterial and endtidal carbondioxide pressure gradient during laparoscopic surgery in adults

A prospective, randomized study to assess the effect of pneumoperitoneum on arterial and endtidal carbondioxide pressure gradient during laparoscopic surgery in adults

... HEMODYNAMIC EFFECTS Our study demonstrates that the intra abdominal pressure of 12 mmHg maintained for laparoscopic surgery induces hemodynamic changes characterised by increase in heart[r] ...

123

Jugular vein distensibility predicts fluid responsiveness in septic patients

Jugular vein distensibility predicts fluid responsiveness in septic patients

... type of comparison. Third, changes in CVP influence the IJV pressure and diameter and may decrease relative distensibility. Conditions associated with increased intra- abdominal or intrathoracic pressure may potentially ...

8

Volumetric, hemodynamic, and excretory characteristics of the liver in acromegaly

Volumetric, hemodynamic, and excretory characteristics of the liver in acromegaly

... Since the values for blood flow were within normal limits, and since plasma concentrations were never excessively high Table II, the observed increase in ICG extraction must be due to in[r] ...

10

Show all 10000 documents...

Related subjects