• No results found

Implantable device

Ultrasound-Based Biomedical Implantable Device.

Ultrasound-Based Biomedical Implantable Device.

... novel device for post-MI regeneration is the capability to monitor the regeneration of the cardiac tissue in vivo without damaging the tissue with a biopsy or sacrificing the ...wireless implantable ...

64

A novel implantable device for a minimally invasive surgical treatment of obstructive sleep apnea: design and preclinical safety assessment

A novel implantable device for a minimally invasive surgical treatment of obstructive sleep apnea: design and preclinical safety assessment

... new implantable device for the management of OSA has been demonstrated through computer modeling, mechanical bench testing, cadaver implantations, and animal implanta- tions to be safe, well tolerated, and ...

10

In vitro and in vivo quantification of chloroprocaine release from an implantable device in a piglet postoperative pain model

In vitro and in vivo quantification of chloroprocaine release from an implantable device in a piglet postoperative pain model

... In vitro, the ACBA metabolite reached the C max after 7 days, whereas chloroprocaine obtained a C max following only 1 day of exposure to the device, and a minimum (C min ) after 7 days. These results suggest that ...

10

A novel implantable device for the treatment of obstructive sleep apnea: clinical safety and feasibility

A novel implantable device for the treatment of obstructive sleep apnea: clinical safety and feasibility

... Study eligibility was confirmed via baseline physical/ otolaryngological examination and standard polysomno- graphic parameters. Surgical procedural times were recorded. Subjects recorded their daily pain ratings (on a ...

8

The Development Of Capacitive Power Transfer For Biomedical Implantable Device

The Development Of Capacitive Power Transfer For Biomedical Implantable Device

... The transmission of electrical energy without wires is called wireless power transfer (WPT). WPT can be accomplished by creating electric, magnetic or electromagnetic coupling between a device and its counterpart ...

24

From micro- to nanostructured implantable device for local anesthetic delivery

From micro- to nanostructured implantable device for local anesthetic delivery

... totally implantable devices (according to the US Food and Drug Administration [FDA], ISO 10993-1 micro/nanodevices must be categorized as implant devices with prolonged exposure to the body) with their full ...

15

Update on bariatric surgical procedures and an introduction to the implantable weight loss device: the Maestro Rechargeable System

Update on bariatric surgical procedures and an introduction to the implantable weight loss device: the Maestro Rechargeable System

... Abstract: There are many different methods of treating obesity, ranging from various medical options to several surgical therapies. This paper briefly summarizes current surgical options for weight loss with a focus on ...

9

A current-mode system to self-measure temperature on implantable optoelectronics

A current-mode system to self-measure temperature on implantable optoelectronics

... In this paper, a CMOS current-mode sensor interface has been presented to measure the temperature variation at the surface of LEDs in optoelectronics. The LED has been employed as a temperature-sensitive element, and its ...

15

The Temperature Field Analysis of the Implantable Medical Device Based on Fluid-Solid Coupling Conjugated Heat Transfer

The Temperature Field Analysis of the Implantable Medical Device Based on Fluid-Solid Coupling Conjugated Heat Transfer

... an implantable medical device; ...3D implantable antenna was suitable for a small radiotactic brain implantable medical device, which could satisfy the distribution of SAR and ...

13

Implantable antennas for biomedical applications

Implantable antennas for biomedical applications

... Implantable antennas inside the human body have two types of biomedical applications. They are Biotelemetry and Biomedical therapy. Biotelemetry can build a wireless communication link between human body and ...

5

Mapping of the Gastrointestinal Short Form Questionnaire (GSF-Q) into EQ-5D-3L and SF-6D in patients with gastroesophageal reflux disease

Mapping of the Gastrointestinal Short Form Questionnaire (GSF-Q) into EQ-5D-3L and SF-6D in patients with gastroesophageal reflux disease

... BMI: Body Mass Index; CFI: Comparative fit index; CIED: Cardiac implantable device; EQ-5D-3 L: EuroQol 5 Dimensions 3 Levels; GERD: Gastroesophageal Reflux Disease; GOF: Goodness-of-fit;[r] ...

11

A compact integrated device for spatially selective optogenetic neural stimulation based on the Utah Optrode Array

A compact integrated device for spatially selective optogenetic neural stimulation based on the Utah Optrode Array

... The design of the UOAs makes it possible to use broad-area laser sources, which can then simultaneously stimulate large areas on the cortical surface and in the deeper tissue layers[19]. Using careful alignment, ...

9

Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis

Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis

... the implantable device system; infection is least frequent in pacemaker patients, more frequent in patients with an ICD and most frequent in biventricular resynchronization therapy patients (with CRT-P or ...

8

Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

... last device related ...epicardial device implantations [19, 23, 28, 29, ...the device or pocket at the time of insertion or during surgical manipu- ...

10

Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

Magnetic resonance imaging in patients with cardiac pacemakers: era of "MR Conditional" designs

... safe device would require nonmetallic, non-conducting materials and systems with no known hazards in all MR environ- ments, it would be impossible to develop a pacing sys- tem with this ...a device requires ...

13

Plain radiography in patients treated with intrathecal drug delivery using an implantable pump device

Plain radiography in patients treated with intrathecal drug delivery using an implantable pump device

... With the magnification view the radiopaque identifier with the company logo and three alphabetic letters can be recognised opposite the pump apex (Fig. 7). When the pump is rotated around its longitudinal axis an odd ...

13

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

... Segmental stenoses, either isolated or multiple, of the vascular lumen were found in 3 cases, with no change observed following lidocaine administration directly into the CV segment visualised in the device ...

7

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

... (ERI)-related device replacement procedures associated with new lead placement; unobstructed contrast flow via the patent axillary vein an subclavian vein; no contrast enhancement of the cephalic vein (CV); ...

6

Novel Molecular and Nanosensors for In Vivo Sensing

Novel Molecular and Nanosensors for In Vivo Sensing

... into implantable sensor devices. A device has been engineered as an implantable diagnostic device for monitoring the cancer biomarker, human chorionic gonadotrophin (hCG-beta), in-vivo [50] ...

12

Hemodynamic deterioration precedes onset of ventricular tachyarrhythmia after Heartmate II implantation

Hemodynamic deterioration precedes onset of ventricular tachyarrhythmia after Heartmate II implantation

... A 47-year-old male with end-stage heart failure due to is- chemic heart disease received a Heartmate II (a rotary continuous flow device) which served as a bridge-to-heart transplantation [20]. Prior to surgery, ...

5

Show all 7996 documents...

Related subjects