• No results found

In vivo biocompatibility

Effects of graphene plates’ adoption on the microstructure, mechanical properties, and in vivo biocompatibility of calcium silicate coating

Effects of graphene plates’ adoption on the microstructure, mechanical properties, and in vivo biocompatibility of calcium silicate coating

... The proliferation and osteogenesis-related genes’ (ALP, OC, OPN) expression of hMSCs on the GPs/CS coating was apparently higher than those on the Ti controls, and showed similar trends with the CS coating. In the ...

9

In vivo biocompatibility and pacing function study of silver ion-based antimicrobial surface technology applied to cardiac pacemakers

In vivo biocompatibility and pacing function study of silver ion-based antimicrobial surface technology applied to cardiac pacemakers

... An ethics committee-approved ovine model was used to test the in vivo performance of these devices. In our model, antimicrobial surface processed and non-pro- cessed control pacemakers were implanted at the same ...

7

Original Article In vivo biocompatibility of the PLGA microparticles in parotid gland

Original Article In vivo biocompatibility of the PLGA microparticles in parotid gland

... In conclusion PLGA microparticles can be safely applied directly to the parotid gland tissue in an animal model, because they modifies slightly morphometric parameters of parenchyma inte[r] ...

7

In vitro and in vivo biocompatibility and osteogenesis of graphene-reinforced nanohydroxyapatite polyamide66 ternary biocomposite as orthopedic implant material

In vitro and in vivo biocompatibility and osteogenesis of graphene-reinforced nanohydroxyapatite polyamide66 ternary biocomposite as orthopedic implant material

... Abstract: Graphene and its derivatives have been receiving increasing attention regarding their application in bone tissue engineering because of their excellent characteristics, such as a vast specific surface area and ...

11

Histological examinations of the in vivo biocompatibility of oxycellulose implanted into rat skeletal muscle

Histological examinations of the in vivo biocompatibility of oxycellulose implanted into rat skeletal muscle

... It has recently been shown that bone defects treated with oxidized cellulose were completely filled with connec- tive tissue with embedded foam cells and that natural.. bone regeneratio[r] ...

7

In vivo Biocompatibility, Biodistribution and Therapeutic Efficiency of Titania Coated Upconversion Nanoparticles for Photodynamic Therapy of Solid Oral Cancers

In vivo Biocompatibility, Biodistribution and Therapeutic Efficiency of Titania Coated Upconversion Nanoparticles for Photodynamic Therapy of Solid Oral Cancers

... subjected to rigorous characterization and its selective cell targeting, ROS generation and PDT efficiency were studied in vitro. Although, UCNs have been deemed safe with no major toxic effects in various reports that ...

22

In vivo biocompatibility of custom-fabricated apatite-wollastonite-mesenchymal stromal cell constructs.

In vivo biocompatibility of custom-fabricated apatite-wollastonite-mesenchymal stromal cell constructs.

... the biocompatibility and osteo supportive capacity of A W scaffolds can be enhanced by SLS custom design, without the requirement for osteogenic pre induction, to advance their potential as patient specific bone ...

33

In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials

In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials

... in vivo implantation of biomaterials into the bone, biomaterials had direct contact with a variety of matrix components and proteins of body tissue fluid and ...

14

Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact

Osteosynthesis-screw augmentation by ultrasound-activated biopolymer - an ovine in vivo study assessing biocompatibility and bone-to-implant contact

... During the study, the in vivo biocompatibility and performance of the so-called “ SonicFusion ™” inside-out technology was tested using a sheep model. Therefore, cannulated screws were augmented by an ...

7

In vivo canine study of three different coatings applied to p64 flow-diverter stents: initial biocompatibility study

In vivo canine study of three different coatings applied to p64 flow-diverter stents: initial biocompatibility study

... in vivo biocompatibility of these ...and biocompatibility of three different hydrophilic ...in vivo testing of three different proprietary HPCs (type 1, 2, and ...

13

Biocompatibility and safety evaluation of a silk fibroin-doped calcium polyphosphate scaffold copolymer in vitro and in vivo

Biocompatibility and safety evaluation of a silk fibroin-doped calcium polyphosphate scaffold copolymer in vitro and in vivo

... the biocompatibility and safety of SF/CPP in vitro and in vivo ...cell biocompatibility was evaluated with regard to the cytotoxicity of the sca ff olds using co-culture and MTT tests in vitro ...in ...

9

Biocompatibility of Graphene Oxide

Biocompatibility of Graphene Oxide

... graphene oxides, respectively, and were raised for 1 day, 7 days, and 30 days, respectively. Results showed that the water-soluble graphene oxides were successfully prepared; graphene oxides with dose less than 20 μg/mL ...

8

Evaluation of the soft tissue biocompatibility of MgCa0.8 and surgical steel 316L in vivo: a comparative study in rabbits

Evaluation of the soft tissue biocompatibility of MgCa0.8 and surgical steel 316L in vivo: a comparative study in rabbits

... The development of biodegradable implants demands an appreciation of the cellular and tissue responses that are associated with their implantation and in vivo degrada- tion, because they determine the ...

17

Comparative Histopathological Evaluation of the
Biocompatibility of AH Plus, Epiphany, RoekoSeal: An
In Vivo Study in Subcutaneous Tissue of Rats

Comparative Histopathological Evaluation of the Biocompatibility of AH Plus, Epiphany, RoekoSeal: An In Vivo Study in Subcutaneous Tissue of Rats

... stances should be critically evaluated for biocompatibility. The AH plus sealer showed moderate-to-severe local tissue reaction (mean score of 2.67) at the 10 days’ time period. Out of the nine slides analyzed, ...

6

Physical properties and biocompatibility of an injectable calcium-silicate-based root canal sealer: in vitro and in vivo study

Physical properties and biocompatibility of an injectable calcium-silicate-based root canal sealer: in vitro and in vivo study

... higher biocompatibility compared to resin-based sealers ...and biocompatibility of this root canal sealer in comparison with MTA (ProRoot; Dentsply, Tulsa, OK, USA) and a resin-based sealer (AHplus; ...

7

MTA versus Biodentine: Review of Literature with a Comparative Analysis

Click here to download PDF version of the article !

... The clinical uses of bioceramics have increased exponentially over the years because of their wide range of applicability in restorative dentistry and endodontics. The introduction of MTA was considered as a major ...

5

TiO2 nanotube platforms for smart drug delivery: a review

TiO<sub>2</sub> nanotube platforms for smart drug delivery: a review

... ex vivo and in vivo animal models have been performed to prove the excellent biocompatibility of the TNT ...in vivo studies should be performed for the local- ized drug delivery systems ...

16

Biocompatibility of Injectable Microspheres

Biocompatibility of Injectable Microspheres

... The increasing need for long lasting injectable soft tissue fillers for the treatment of wrinkles and skin defects, gastric reflux, urinary and fecal incontinence, and other indications requires a critical discussion of ...

11

Degradability,  biocompatibility, and osteogenesis of biocomposite scaffolds containing nano magnesium phosphate and wheat protein both in vitro and in vivo for bone regeneration

Degradability, biocompatibility, and osteogenesis of biocomposite scaffolds containing nano magnesium phosphate and wheat protein both in vitro and in vivo for bone regeneration

... Bioactive scaffolds of MWCs were fabricated in this study. The results showed that MWC scaffolds were well-interconnected macroporous structures and some micropores were found on the walls of the macroporores. The MWC ...

15

Enhanced Biocompatibility in Anodic TaOx
               Nanotube Arrays

Enhanced Biocompatibility in Anodic TaOx Nanotube Arrays

... the biocompatibility of self-organized TaO x nanotube arrays with different nanotube diameters fabricated by electrochemical ...vitro biocompatibility evaluation further indicates that fibroblast cells ...

8

Show all 10000 documents...

Related subjects