• No results found

Intra Aortic Balloon Pump (IABP)

Intra-aortic balloon pump in patients with cardiogenic shock complicating myocardial infarction: a systematic review and meta-analysis of randomized trials (protocol)

Intra-aortic balloon pump in patients with cardiogenic shock complicating myocardial infarction: a systematic review and meta-analysis of randomized trials (protocol)

... (systolic blood pressure <80 to 90 mmHg or mean arter- ial pressure 30 mmHg lower than baseline) with severe reduction in the cardiac index (<1.8 l.min − 1 .m 2 without support or <2.0 to 2.2 l.min − 1 .m 2 with ...

5

The outcomes of intra-aortic balloon pump usage in patients with acute myocardial infarction: a comprehensive meta-analysis of 33 clinical trials and 18,889 patients

The outcomes of intra-aortic balloon pump usage in patients with acute myocardial infarction: a comprehensive meta-analysis of 33 clinical trials and 18,889 patients

... Notes: The odds ratio (Or) of in-hospital all-cause mortality (A) and long-term all-cause mortality (B) among the patients suffering from AMi complicated by cs, as well as midterm all-cause mortality (C) and the ...

16

Intra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump

Intra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump

... In the framework of a comprehensive research, Wasfie et al [26] investigated 733 cases of patients undergoing intra aortic balloon pump treatment. One hundred thirty two of the patients were ...

6

Acute and critically ill peripartum cardiomyopathy and 'bridge to' therapeutic options: a single center experience with intra aortic balloon pump, extra corporeal membrane oxygenation and continuous flow left ventricular assist devices

Acute and critically ill peripartum cardiomyopathy and 'bridge to' therapeutic options: a single center experience with intra aortic balloon pump, extra corporeal membrane oxygenation and continuous flow left ventricular assist devices

... Heart transplantation is an accepted treatment option for patients with refractory heart failure due to PPCM, although a higher incidence of rejection has been reported in parous women, particularly in the first six ...

7

OUTCOMES WITH INTRA-AORTIC BALLOON PUMP IN HIGH RISK CARDIAC SURGERY PATIENTS

OUTCOMES WITH INTRA-AORTIC BALLOON PUMP IN HIGH RISK CARDIAC SURGERY PATIENTS

... of intra-aortic balloon pump (IABP) on the outcome of high-risk patients subjected to coronary artery bypass graft (CABG) surgery with low ejection fraction ≤ 35% and compare the observed ...

8

The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome

The need for intra aortic balloon pump support following open heart surgery: risk analysis and outcome

... Intra-aortic balloon pump (IABP) is the most usable tool of temporary mechanical circulatory support for cardiac surgical patients suffered from low cardiac out- put in the early postoperative ...

7

Effectiveness of capacity building program regarding care of patient with Intra Aortic Balloon Pump (IABP) upon the level of knowledge and practice among Nurses

Effectiveness of capacity building program regarding care of patient with Intra Aortic Balloon Pump (IABP) upon the level of knowledge and practice among Nurses

... This chapter deals with a brief description of different steps undertaken by the researcher for the study. It includes research approach, research design, variables, under study, setting, population, sample size, ...

144

Effects of intra aortic balloon pump on cerebral blood flow during peripheral venoarterial extracorporeal membrane oxygenation support

Effects of intra aortic balloon pump on cerebral blood flow during peripheral venoarterial extracorporeal membrane oxygenation support

... that intra-aortic balloon pump (IABP) sup- port in patients after cardiac surgery caused a considerable increase in the flow velocity in the middle cerebral artery ...

8

Intra-aortic balloon pump-assisted major hepatectomy in a case with coronary disease

Intra-aortic balloon pump-assisted major hepatectomy in a case with coronary disease

... Clinically, we often encounter cancer patients who also have cardiovascular disease such as coronary artery disease. We experienced a case of severe coronary artery disease and a large hepatocellular carcinoma in a ...

6

Original Article Effectiveness of the intra-aortic balloon pump on emergency percutaneous coronary intervention for left anterior descending opening occlusion-induced acute myocardial infarction

Original Article Effectiveness of the intra-aortic balloon pump on emergency percutaneous coronary intervention for left anterior descending opening occlusion-induced acute myocardial infarction

... the intra-aortic balloon pump (IABP) in emer- gency percutaneous coronary intervention (PCI) for left anterior descending opening occlusion-induced acute myo- cardial infarction ...

10

Preoperative intra aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta analysis of randomized controlled trials

Preoperative intra aortic balloon pump to reduce mortality in coronary artery bypass graft: a meta analysis of randomized controlled trials

... preoperative intra-aortic balloon pump in patients undergoing coronary artery bypass grafting either with or without cardiopulmonary bypass were ...

8

Role of Intra Aortic Balloon Pump in Off Pump Coronary Artery Bypass —A Vettath Modification

Role of Intra Aortic Balloon Pump in Off Pump Coronary Artery Bypass —A Vettath Modification

... of intra-aortic bal- loon pump has been shown to prevent this complication in high risk ...of balloon pump in high risk patients has been questioned by our ...of balloon ...

8

Intra-aortic balloon pump does not influence cerebral hemodynamics and neurological outcomes in high-risk cardiac patients undergoing cardiac surgery: an analysis of the IABCS trial

Intra-aortic balloon pump does not influence cerebral hemodynamics and neurological outcomes in high-risk cardiac patients undergoing cardiac surgery: an analysis of the IABCS trial

... differences in insonation angle, the chance of arteries other than the MCA being insonated and intersubject anatomical differences, including the acoustic perme- ability of temporal windows, are factors that need to be ...

11

Evaluation of preoperative intra-aortic balloon pump in coronary patients with severe left ventricular dysfunction undergoing OPCAB surgery: early and mid-term outcomes

Evaluation of preoperative intra-aortic balloon pump in coronary patients with severe left ventricular dysfunction undergoing OPCAB surgery: early and mid-term outcomes

... of intra-aortic bal- loon pump (IABP) in these patients may prevent this and thus avoid the institution of CPB with its attendant risks which include inflammation and global ischemia[6,7] The use of ...

8

Effectiveness of capacity building program regarding care of patient with Intra Aortic Balloon Pump (IABP) upon the level of knowledge and practice among Nurses

Effectiveness of capacity building program regarding care of patient with Intra Aortic Balloon Pump (IABP) upon the level of knowledge and practice among Nurses

... • Similarly, aortic rupture can occur if IABP is inserted in patients with sizable abdominal aortic aneurysms. Patients with end-stage cardiac disease should not be considered for IABP unless as a bridge to ...

33

Withdrawing intra aortic balloon pump support paradoxically improves microvascular flow

Withdrawing intra aortic balloon pump support paradoxically improves microvascular flow

... Although speculative, one possible explanation for the observed difference in microvascular perfusion could be a mechanical effect of IABP. The pressure decrease induced by balloon deflation during diastole could ...

7

The Usefulness of Ryusei® Perfusion Balloon for Treating Acute Coronary Syndrome with Vulnerable Plaque

The Usefulness of Ryusei® Perfusion Balloon for Treating Acute Coronary Syndrome with Vulnerable Plaque

... use intra-aortic balloon pump (IABP) in patients with the no reflow phenomenon with the ex- pectation of an increase in diastolic coronary flow and improved cardiac func- tion ...Perfusion ...

12

Long-term outcome of a dilated cardiomyopathy patient after mitral valve surgery combined with tissue-engineered myoblast sheets—report of a case

Long-term outcome of a dilated cardiomyopathy patient after mitral valve surgery combined with tissue-engineered myoblast sheets—report of a case

... extracorporeal pump was successfully removed with an intra-aortic balloon pump (IABP) and adequate catecholamine infusion, and post-operative heart failure was well controlled with ...

6

Investigation of the use of Electro Active Polymer as a Pediatric VAD Driver

Investigation of the use of Electro Active Polymer as a Pediatric VAD Driver

... Electrorheological Fluid ERF Extracorporeal Membrane Oxygenation ECMO Inferior Vena Cava IVC Integrated Circuit IC Intensive Care Unit ICU Intra-Aortic Balloon Pump IABP Ionic Polymer Me[r] ...

326

Download
			
			
				Download PDF

Download Download PDF

... to severe left ventricular dysfunction (8, 11, 12). The exact mechanism of its toxicity is unclear, but the release of phosphine gas as well as cytochrome oxidase inhibition, oxidative stress, and free oxygen radicals ...

7

Show all 9622 documents...

Related subjects