• No results found

Neutron-Capture Therapy

Clinical potential of boron neutron capture therapy for locally recurrent inoperable previously irradiated head and neck cancer

Clinical potential of boron neutron capture therapy for locally recurrent inoperable previously irradiated head and neck cancer

... Optimal therapy has not been established and prognosis is gen- erally poor (Tanvetyanon et ...Boron Neutron Capture Therapy (BNCT) has also been ...

5

Arene ruthenium dithiolato–carborane complexes for boron neutron capture therapy (BNCT)

Arene ruthenium dithiolato–carborane complexes for boron neutron capture therapy (BNCT)

... Boron neutron capture therapy is the traditional area for application of dicarba-closo-dodecarborane molecules in ...this therapy depends on the number of boron atoms delivered to cancer ...

10

Boron neutron capture therapy – redefining radiotherapy

Boron neutron capture therapy – redefining radiotherapy

... First, there is a need for more selective and effective boron agents that, when used either alone or in combination. Furthermore, their delivery must be optimized to improve both tumor uptake and cellular ...

7

In Vitro Evaluation System of Pharmacokinetics and Irradiation Effect in Boron Neutron Capture Therapy (BNCT) Using Three Dimensional Artificial Human Tumor Tissue Model

In Vitro Evaluation System of Pharmacokinetics and Irradiation Effect in Boron Neutron Capture Therapy (BNCT) Using Three Dimensional Artificial Human Tumor Tissue Model

... DOI: 10.4236/jct.2019.1010071 838 Journal of Cancer Therapy of 40 ppm with DMEM containing 10% FBS. This is referred to as a BPA treat- ment solution. After removing the culture solution of NHDF3D or NHDF3D/ ...

11

Direct Synthesis of Li3N Thin Layer on Lithium Target Surface for BNCT in N2 Gaseous Conditions

Direct Synthesis of Li3N Thin Layer on Lithium Target Surface for BNCT in N2 Gaseous Conditions

... Implemented deployment of accelerator-driven neutron source for boron neutron capture therapy (BNCT) is scheduled in 2014 in National Cancer Center, Japan. This BNCT system was designed with ...

5

Deterministic Parsing Model of the  Compound Biological Effectiveness (CBE) Factor for Intracellular 10Boron Distribution in Boron Neutron Capture Therapy

Deterministic Parsing Model of the Compound Biological Effectiveness (CBE) Factor for Intracellular 10Boron Distribution in Boron Neutron Capture Therapy

... previously developed a deterministic parsing model to determine the Compound Biological Effec- tiveness (CBE) factor in Borono-Phenyl-Alanine (BPA)-mediated Boron Neutron Capture Therapy (BNCT). In ...

12

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

Characteristics of Filtered Neutron Beam Energy Spectra at Dalat Reactor

... The neutron transmission neutron filters technique [1] has been successfully applied to produce quasi-monoe- nergetic neutrons for basic research and ...as neutron total and capture reaction ...

7

Radiation Sensitivity of in Vitro Evaluation System of Pharmacokinetics in Boron Neutron Capture Therapy (BNCT) Using Three Dimensional Artificial Human Tumor Tissue Model

Radiation Sensitivity of in Vitro Evaluation System of Pharmacokinetics in Boron Neutron Capture Therapy (BNCT) Using Three Dimensional Artificial Human Tumor Tissue Model

... DOI: 10.4236/jct.2019.1012086 1027 Journal of Cancer Therapy Figure 1. Procedures for detection of BNCT reaction by using in vitro three-dimensional artificial human tumor tissue model. (a) Fabrication process of ...

11

Folate Functionalized Boron Nitride Nanotubes and their Selective Uptake by Glioblastoma Multiforme Cells: Implications for their Use as Boron Carriers in Clinical Boron Neutron Capture Therapy

Folate Functionalized Boron Nitride Nanotubes and their Selective Uptake by Glioblastoma Multiforme Cells: Implications for their Use as Boron Carriers in Clinical Boron Neutron Capture Therapy

... Boron neutron capture therapy (BNCT) is increasingly being used in the treatment of several aggressive cancers, including cerebral glioblastoma multi- ...this therapy is selective targeting of ...

9

3 (4 Di­hydroxy­boryl­phenyl)­cyclo­butanone1

3 (4 Di­hydroxy­boryl­phenyl)­cyclo­butanone1

... chemical therapy or radiation therapy; boron neutron capture therapy (BNCT) has been recently considered as an alternative useful method for treating hepatoma (Aris et ...

7

Metal complexes as potential anticancer agents

Metal complexes as potential anticancer agents

... Boron neutron capture therapy (BNCT) is a type of cancer treatment that combines elements of both radiotherapy and chemotherapy for the destruction of tum ...this therapy is to introduce ...

163

Experiments with neutron beams for the astrophysical s process

Experiments with neutron beams for the astrophysical s process

... the neutron energy is determined via the time-of-flight of the neutron for each capture ...pulsed neutron beam is produced by reactions of a charged particle beam with a neutron ...

7

Simulation of Gamma Ray and Neutron Spectrometers for Microsatellite Missions

Simulation of Gamma Ray and Neutron Spectrometers for Microsatellite Missions

... There are two fundamental gamma-ray emission processes: through decay of radioactive nuclei and by nuclear interactions between neutrons and target nuc- lei. Celestial bodies with thin or no atmosphere are always exposed ...

28

The Nuclear Astrophysics program at n-TOF (CERN)

The Nuclear Astrophysics program at n-TOF (CERN)

... regarded neutron capture cross ...of capture reactions have been measured, in EAR1, on a variety of subjects, from neutron magic nuclei, acting as bottleneck for the reaction flow of the ...

9

Galactic Pal eontology:abundance analysis of the disrupted globular cluster Palomar 5

Galactic Pal eontology:abundance analysis of the disrupted globular cluster Palomar 5

... We present a chemical abundance analysis of the tidally disrupted globular cluster (globular cluster) Palomar 5. By co-adding high- resolution spectra of 15 member stars from the cluster’s main body, taken at ...

8

Real Time Range of Motion Measurement of Physical Therapeutic Exercises

Real Time Range of Motion Measurement of Physical Therapeutic Exercises

... motion capture systems are generally expensive, difficult to use, and currently not suited for real-time ...tion capture system (HMCS) consisting of a single camera and a graphical processing unit (GPU) to ...

24

Astrophysical Radiative Neutron Capture on 10B Taking into Account Resonance at 475 keV

Astrophysical Radiative Neutron Capture on 10B Taking into Account Resonance at 475 keV

... the capture reactions as a function of energy is very important for investigation of many astro- physical problems such as primordial nucleosynthesis of the universe, main trends of stellar evolution, novae and ...

14

Determination of the neutron-capture rate of 17C for r-process nucleosynthesis

Determination of the neutron-capture rate of 17C for r-process nucleosynthesis

... a neutron in p- or f -waves were taken into ...a neutron-core interaction correspond- ing to a plane-wave ...the neutron separation threshold in 18 C from theoretical calculations [16, ...

10

Evaluation of Boron Content Liposome Modified Protein- Transduction Domains for Boron Neutron Capture Therapy

Evaluation of Boron Content Liposome Modified Protein- Transduction Domains for Boron Neutron Capture Therapy

... radiation therapy as a treatment for malignant tumors becomes greater every year, but radiation therapy-resistant tumors still exist, and are known as convalescence ...Boron neutron capture ...

6

Development of 24 and 59 keV Filtered Neutron Beams for Neutron Capture Experiments at Dalat Research Reactor

Development of 24 and 59 keV Filtered Neutron Beams for Neutron Capture Experiments at Dalat Research Reactor

... filtered neutron beams have been developed at the horizontal radial channels ...the neutron filters, the primary material components of Iron, Aluminum, Nickel and Vanadium are used to obtain the ...

6

Show all 10000 documents...

Related subjects