• No results found

Non Invasive Cardiac Output

Early non invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi center randomized controlled trial

Early non invasive cardiac output monitoring in hemodynamically unstable intensive care patients: A multi center randomized controlled trial

... early, non-invasive continu- ous cardiac output monitoring did not shorten the time to reach hemodynamic stability, produce any outcome benefit, or reduce the amount of resources used during ...

9

Emergency department non-invasive cardiac output study (EDNICO): a feasibility and repeatability study

Emergency department non-invasive cardiac output study (EDNICO): a feasibility and repeatability study

... investigating non-invasive cardiac output monitoring in the emergency department ...six non-invasive fluid responsiveness monitoring methods which measure cardiac ...

9

Emergency department non-invasive cardiac output study (EDNICO): an accuracy study

Emergency department non-invasive cardiac output study (EDNICO): an accuracy study

... Non-invasive cardiac output monitoring methods are emerging in the ED and in the pre-hospital environment [16, ...measuring cardiac output, has been studied as an indicator of ...

9

Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non invasive cardiac output monitoring in pediatric intensive care patients: a prospective single center observational study

Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non invasive cardiac output monitoring in pediatric intensive care patients: a prospective single center observational study

... including non-invasive devices (for example, continuous Doppler-based systems) [34,35] and invasive devices (for example, transpulmonary thermodilution methods combined with pulse contour analysis) ...

9

Correlation of Electric Cardiometry and Continuous Thermodilution Cardiac Output Monitoring Systems

Correlation of Electric Cardiometry and Continuous Thermodilution Cardiac Output Monitoring Systems

... is invasive and has been criticized for its cost and risk-benefit ratio ...for non-invasive devices for the measurement of ...continuous non-invasive cardiac output ...

9

Comparison of two continuous non-invasive haemodynamic monitoring techniques in the perioperative setting

Comparison of two continuous non-invasive haemodynamic monitoring techniques in the perioperative setting

... the cardiac output and arterial oxygen content rather than on the arterial blood pressure, therefore advanced haemodynamic monitoring takes a pivotal role in providing addi- tional information about the  ...

7

Non-invasive quantification of cardiac stroke volume in the edible crab Cancer pagurus

Non-invasive quantification of cardiac stroke volume in the edible crab Cancer pagurus

... to cardiac output in spider crabs Maja squinado [5], most likely because of the strong effect of sensor position on signal ...the cardiac circle (compare ...

15

Initial Hemodynamic Profiles of Children with Dengue Shock Syndrome in Referral Settings

Initial Hemodynamic Profiles of Children with Dengue Shock Syndrome in Referral Settings

... the non-invasive Ultrasonic Cardiac Output Monitor ...fluid non responsive state, 90,38% had low inotropic index and high systemic vascular resistance ...low cardiac Index, fluid ...

7

Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements

Correlation of carotid blood flow and corrected carotid flow time with invasive cardiac output measurements

... Background: Non-invasive measures that can accurately estimate cardiac output may help identify volume- responsive ...two non-invasive measures (corrected carotid flow time and ...

8

In vivovalidation of a new non invasive continuous ventricular stroke volume monitoring system in an animal model

In vivovalidation of a new non invasive continuous ventricular stroke volume monitoring system in an animal model

... absolute cardiac output value above absolute cardiac output values of more than 2 ...of cardiac output by the HCP in the range below 2 L/minute, as can be seen from the ...

8

The value of non-invasive measurement of cardiac output and total peripheral resistance to categorize significant changes of intradialytic blood pressure: a prospective study

The value of non-invasive measurement of cardiac output and total peripheral resistance to categorize significant changes of intradialytic blood pressure: a prospective study

... sured. Cardiac output (CO) is calculated by CO = heart rate (HR)* SV and cardiac index (CI) is calculated as div- iding CO by body surface area ...

6

Investigating the ability of non-invasive measures of cardiac output to detect a reduction in blood volume resulting from venesection in spontaneously breathing subjects

Investigating the ability of non-invasive measures of cardiac output to detect a reduction in blood volume resulting from venesection in spontaneously breathing subjects

... Monitoring cardiac output (CO) in shocked patients provides key etiological information and can be used to guide fluid resuscitation to improve patient ...on invasive monitoring, restricting its use ...

7

Accuracy and Efficacy of Impedance Cardiography as a Non Invasive Cardiac Function Monitor

Accuracy and Efficacy of Impedance Cardiography as a Non Invasive Cardiac Function Monitor

... the continuous thermodilution method may not detect sud- den changes in CO compared to arterial pressure waveform analysis or ICG. In our study, the bias between arterial pres- sure waveform analysis and ICG, which have ...

7

Comparison of Cardiac Output Measurement by Noninvasive Method with Electrical Cardiometry and Invasive Method with Thermodilution Technique in Patients Undergoing Coronary Artery Bypass Grafting

Comparison of Cardiac Output Measurement by Noninvasive Method with Electrical Cardiometry and Invasive Method with Thermodilution Technique in Patients Undergoing Coronary Artery Bypass Grafting

... for non-invasive method of measuring continuous cardiac out- put monitoring based on measurement of thoracic electrical ...the cardiac-induced pulsa- tile component of the total change in ...

9

Comparison between Flotrac Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring

Comparison between Flotrac Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring

... continuous cardiac output (CO) monitoring required an invasive method, via a pulmonary artery catheter for ...totally Non Invasive CO Monitoring (NICOM™) device, based on chest ...

6

Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient

Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient

... Transthoracic echocardiography (TTE) is a non- invasive means of hemodynamic assessment that can be applied to critically ill patients. TTE can be used to esti- mate CO in several ways. The most frequently ...

8

Reliability of continuous cardiac output measurement during intra abdominal hypertension relies on repeated calibrations: an experimental animal study

Reliability of continuous cardiac output measurement during intra abdominal hypertension relies on repeated calibrations: an experimental animal study

... arterial pressure difference by PulseCO and changes of arte- rial compliance are possible explanations for the lack of accu- racy to depict changes in CO. In the present study, PulseCO was only calibrated by the lithium ...

9

Routine Primary PCI; Whether and When Necessary for the Management of NSTEMI—An Evidence Based Evaluation

Routine Primary PCI; Whether and When Necessary for the Management of NSTEMI—An Evidence Based Evaluation

... It considered based on patients weight, age, renal function and history of bleeding complications. If there is plan for coronary angiography within 24 hours of admission and there is no significant renal impairment ...

8

Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device

Changes in stroke volume induced by passive leg raising in spontaneously breathing patients: comparison between echocardiography and Vigileo™/FloTrac™ device

... (cardiac output obtained with Vigileo device (CO-Flotrac))and SV (stroke volume obtained with Vigileo device (SV-Flotrac)), needs no external calibration and provides continuous CO measurements from the ...

8

Applications of Raman micro spectroscopy to stem cell technology: label free molecular discrimination and monitoring cell differentiation

Applications of Raman micro spectroscopy to stem cell technology: label free molecular discrimination and monitoring cell differentiation

... and non-CMs achieved 97% specificity and 96% sensitivity ...during cardiac differentiation, and then to correlate these changes to gold-standard fluorescence staining for the cardiac phenotype ...

14

Show all 10000 documents...

Related subjects