• No results found

Stenosed Artery

Pulsatile MHD Flow in an Inclined Catheterized Stenosed Artery with Slip on the Wall

Pulsatile MHD Flow in an Inclined Catheterized Stenosed Artery with Slip on the Wall

... the artery. Effects of catheter in stenosed artery can be estimated non-invasively by means of hemo- dynamic indicator-WSS, WSSG, volume flow rate and ...the artery and magnetic field on the ...

14

Generalized power-law model of magnetohydrodynamic blood flow in an inclined stenosed artery with body acceleration

Generalized power-law model of magnetohydrodynamic blood flow in an inclined stenosed artery with body acceleration

... in stenosed artery is of considerable medical interest in the investigation of the formation and development of ...the artery causes blood flow separation and complex hemodynamic features and these ...

50

A Casson Fluid Model for Multiple Stenosed Artery in the Presence of Magnetic Field

A Casson Fluid Model for Multiple Stenosed Artery in the Presence of Magnetic Field

... multistenosed artery under the influence of external applied magnetic field is ...The artery is modeled as a circular ...multi stenosed artery are obtained leading to medical ...

6

EFFECT OF PULSATILE FLOW OF BLOOD THROUGH MULTIPLE STENOSED ARTERY IN THE PRESENCE OF MAGNETIC FIELD AND BODY ACCELERATION.

EFFECT OF PULSATILE FLOW OF BLOOD THROUGH MULTIPLE STENOSED ARTERY IN THE PRESENCE OF MAGNETIC FIELD AND BODY ACCELERATION.

... a stenosed artery and observed that all the instantaneous flow characteristics are affected by the application of body ...constricted artery with body acceleration and observed that the velocity and ...

8

Hydromagnetic effect on inclined Pulsating flow of blood in a multiple stenosed artery

Hydromagnetic effect on inclined Pulsating flow of blood in a multiple stenosed artery

... shape stenosed artery under the influence of magnetic field and demonstrated the effect of stenosis shape and magnetic field on the resistance to the ...multi-stenotic artery under the effects of ...

8

Mathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium

Mathematical modeling of blood flow in a stenosed artery under MHD effect through porous medium

... In this paper, the application of porous medium for the study of blood flow through stenosed artery in the presence of transverse magnetic field is made. The application of magnetohydrodynamics in ...

9

Heat and Mass Transfer on MHD Two Phase Blood Flow through a Stenosed Artery with Permeable Wall

Heat and Mass Transfer on MHD Two Phase Blood Flow through a Stenosed Artery with Permeable Wall

... on stenosed artery of the graphs of the variations of wall shear stress, resistive impedance, volumetric flow rate and velocity profile have been plotted which show their sinusoidal behavior with ...in ...

9

Performance of blood flow through two phase stenosed artery using Herschel-Bulkley model

Performance of blood flow through two phase stenosed artery using Herschel-Bulkley model

... and 15]. In 2010, Singh et al. [16] have dealt blood flow model through radially non-symmetric stenosed artery. In 2008, Radhakrishnamcharya and Prasad have proposed blood flow through an inclined tube with ...

14

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

Mathematical Modeling of Micropolar Blood Flow in a Stenosed Artery Under the Body Acceleration and Magnetic Field

... tapered stenosed artery subjected to external magnetic field and body acceleration has received little at- ...tapered stenosed artery with empha- sis on micropolar nature of blood using ...

10

Slip Effects on the Flow of a Second Grade Fluid in a Varying Width Channel with Application to Stenosed Artery

Slip Effects on the Flow of a Second Grade Fluid in a Varying Width Channel with Application to Stenosed Artery

... A significant amount of interest has been paid to the problem of flow through channels of varying gap and non-uniform pipes with slip effects. Flows through elas- tic tubes, blood circulation through capillaries are some of ...

10

Unsteady two layered blood flow through a w shape stenosed artery using the generalized oldroyd b fluid model

Unsteady two layered blood flow through a w shape stenosed artery using the generalized oldroyd b fluid model

... model. The geometry of the overlapping stenosis is carefully defined. Viscous flow characteristics of blood in a stenosed artery for Carreau, Olroyd-B model and Maxwell models are compared. The paper is ...

26

Nonlinear wave modulation in a fluid filled thin elastic stenosed artery

Nonlinear wave modulation in a fluid filled thin elastic stenosed artery

... This research presents four mathematical models for nonlinear wave mod- ulation through the stenosed artery. The results will be an interest in determining whether the disorderly blood flow patterns can be ...

53

Mathematical Modelling on blood flow through Stenosed artery under the influence of Magnetic field

Mathematical Modelling on blood flow through Stenosed artery under the influence of Magnetic field

... mild stenosed artery under the influence of magnetic ...in stenosed artery increases along the tube length, on decreasing the Hartman ...

7

The effects of gravitational acceleration on micropolar fluid model of blood flow in a bifurcated stenosed artery

The effects of gravitational acceleration on micropolar fluid model of blood flow in a bifurcated stenosed artery

... in stenosed artery. So, choice o f artery geometry is the first concern before proceeding to problem ...f artery geometry involved in this research, which are a finite segment o f straight ...

35

Mathematical modeling of blood flow through tapered stenosed artery with the suspension of nanoparticles using jeffrey fluid model

Mathematical modeling of blood flow through tapered stenosed artery with the suspension of nanoparticles using jeffrey fluid model

... constricted stenosed artery is very important in the medical domain because of the fact that many of the diseases such as heart attacks and strokes are related to blood flow and also the physical ...

7

A numerical simulation and visualization of blood flow through a stenosed artery with the different severity

A numerical simulation and visualization of blood flow through a stenosed artery with the different severity

... A stenosed artery is the result o f atherosclerosis that is hardening o f the artery due to the growth o f a calcified plaque layer on the inner walls o f the artery (Layak et ...

20

Analysis of Pulsatile Magnetohydrodynamic (MHD) Third Grade Blood Flow in a Stenosed Artery

Analysis of Pulsatile Magnetohydrodynamic (MHD) Third Grade Blood Flow in a Stenosed Artery

... In this research, we modeled MHD third grade blood flow in a stenosed ar- tery. The blood viscosity and the density have been modeled into the shear thinning/thickening parameters, the most important rheological ...

18

Numerical Modeling of Two-Layered Micropolar Fluid Through an Normal and Stenosed Artery

Numerical Modeling of Two-Layered Micropolar Fluid Through an Normal and Stenosed Artery

... Abstract In the present work a two fluid model for blood flow through abnormally constricted human artery (stenosed artery) has been developed. The model consists of a core region of suspension of ...

11

Numerical modelling and simulation of blood flow through a multi-irregular stenosed artery

Numerical modelling and simulation of blood flow through a multi-irregular stenosed artery

... In Chapter 3, the first problem which discusses the response of body acceleration on blood flow through a multi-irregular stenosed artery is presented. This chapter is divided into eight main sections ...

26

Variable viscosity thermal hemodynamic slip flow conveying nanoparticles through a permeable walled composite stenosed artery

Variable viscosity thermal hemodynamic slip flow conveying nanoparticles through a permeable walled composite stenosed artery

... magnetohydrodynamics and peristalsis in presence of velocity and slip effects. Two types of nanoparticles (Ag and SiO2) have been considered. They found that the pressure gradient for Ag nanofluid is minimum and it is ...

24

Show all 6898 documents...

Related subjects