• No results found

Transient Elastography with Probe

Transient elastography with the XL probe rapidly identifies patients with nonhepatic ascites

Transient elastography with the XL probe rapidly identifies patients with nonhepatic ascites

... that probe positioning, namely angu- lation, towards the phantom is critical, as has been shown for transient elastography in ...the probe is required to prevent overestimation of ...

8

Clinical Utilities of Transient Elastography

Clinical Utilities of Transient Elastography

... 3.4.2.2 Transient elastography TE (Fibroscan, Echosens Paris France) enables non-invasive assessment of liver fibrosis using ultrasonic elastography ...Fibroscan probe consists of an ...

289

Electronic hardware design for ultrasound Transient Elastography

Electronic hardware design for ultrasound Transient Elastography

... Ultrasonography is a diagnostic imaging technique used for visualizing subcutaneous body structures including tendons, muscles, joints, vessels and internal organs for possible pathology or lesions. Sound waves are ...

5

An ultrasound transient elastography system with coded excitation

An ultrasound transient elastography system with coded excitation

... wave elastography using the plane wave imag- ing also suffers from poor penetration ...a probe dedi- cated to obese patients and controlled attenuation parameter is developed to assess liver steatosis, too ...

10

Interconversion of elasticity measurements between two-dimensional shear wave elastography and transient elastography

Interconversion of elasticity measurements between two-dimensional shear wave elastography and transient elastography

... This study has some limitations. First, we did not cor- relate the elastographic results with the pathologic results. Liver biopsy was not included in the routine management plan for pediatric patients in our institution ...

7

Transient elastography for predicting esophageal/gastric varices in children with biliary atresia

Transient elastography for predicting esophageal/gastric varices in children with biliary atresia

... [11]. Transient elastography was performed by a well- trained nurse using FibroScan 502 (Echosens, Paris, ...transducer probe of FibroScan on the intercostal space at the area of the right liver lobe ...

5

Electronic Design of Compact Power Supply Unit for Various Voltages in Ultrasound Transient Elastography

Electronic Design of Compact Power Supply Unit for Various Voltages in Ultrasound Transient Elastography

... diseases. Transient Elastography is one of the imaging modalities by which the elasticity of the tissues is qualitatively and quantitatively measured ...transducer probe are excited ...

5

2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis

2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis

... The technique for SWE All patients were placed supine or left semi-lateral de- cubitus with the 2D convex probe placed on the midcla- vicular line or anterior axillary line in the intercostal spaces until ...

9

Prospective comparison of transient elastography and liver biopsy for the assessment of fibrosis in chronic hepatitis C infection

Prospective comparison of transient elastography and liver biopsy for the assessment of fibrosis in chronic hepatitis C infection

... which correlates with hepatic fibrosis stages. This technique is routinely used in clinical practice to assess noninvasively liver stiffness. The Fibroscan system generates a shear wave via an impulse stress applied on ...

5

The inverse effect of meal intake on controlled attenuation parameter and liver stiffness as assessed by transient elastography

The inverse effect of meal intake on controlled attenuation parameter and liver stiffness as assessed by transient elastography

... Measurement of liver stiffness (LS) and controlled attenuation parameter (CAP) A single operator who had experiences of more than 1000 cases of TE measurement performed TE in this study. While the patients were lying on ...

7

Noninvasive Transient Elastography identifies initial stage liver fibrosis & cirrhosis in Hepatitis B patients

Noninvasive Transient Elastography identifies initial stage liver fibrosis & cirrhosis in Hepatitis B patients

... Various measurements were carried out on patients’ right liver lobe, lying on the back with the full abduction of right arm. The transducer tip was coated with coupling gel and placed between the rib bones onto the skin ...

5

Prospective Comparison of Transient Elastography Using Two Different Devices: Performance of FibroScan and FibroTouch

<p>Prospective Comparison of Transient Elastography Using Two Different Devices: Performance of FibroScan and FibroTouch</p>

... Apart from the fi brosis-associated elevation of LS, it is now clear that other conditions can also increase and strongly modulate LS irrespective of fi brosis. 4 First major confounders of LS elevation encompassed hepatic ...

8

Acoustic Radiation Force Impulse and Supersonic Shear Imaging Versus Transient Elastography for Liver Fibrosis Assessment

Acoustic Radiation Force Impulse and Supersonic Shear Imaging Versus Transient Elastography for Liver Fibrosis Assessment

... Supersonic shear imaging was performed with an Aixplorer ultrasound system (SuperSonic Imagine, Aix- en-Provence, France), using a SC6–1 convex probe. The principle underlying SSI involves the combination of a ...

9

Transient elastography and controlled attenuation parameter (CAP) in the assessment of liver steatosis in severe adult growth hormone deficiency

Transient elastography and controlled attenuation parameter (CAP) in the assessment of liver steatosis in severe adult growth hormone deficiency

... ). Transient elastography (TE) by FibroScan R has been widely used in the last decade as a fast, non-invasive, and reproducible method to evaluate the liver stiffness measurement (LSM) as a measure of the ...

9

Relevance of Adipose Tissue Stiffness Evaluated by Transient Elastography (AdipoScan™) in Morbidly Obese Patients before Bariatric Surgery

Relevance of Adipose Tissue Stiffness Evaluated by Transient Elastography (AdipoScan™) in Morbidly Obese Patients before Bariatric Surgery

... R. Transient elastography: a new noninvasive method for assessment of hepatic ...elasticity probe for soft tissues with 1-D transient ...

5

Original Article Transient liver elastography profiles in a hospital-based pediatric population with infectious mononucleosis in southern China

Original Article Transient liver elastography profiles in a hospital-based pediatric population with infectious mononucleosis in southern China

... associated IM have not been reported when using TE. Therefore, this study aimed to evalu- ate liver fibrosis in IM caused by EBV infection. Newly-developed non-invasive diagnostic tech- niques, based on ultrasound ...

9

Handheld probe for quantitative micro elastography

Handheld probe for quantitative micro elastography

... 4. Discussion In QME, we typically acquire a 3-D scan during each acquisition [12,23]. This approach enables micro-elastograms to be presented in the en face plane, as has been demonstrated in this paper. Two key ...

16

Transient elastography in chronic hepatitis B: an Asian perspective

Transient elastography in chronic hepatitis B: an Asian perspective

... Thus, we focused on TE in the Asian population with CHB in comparison with the European population with CHC and found that the diagnostic performance and cutoff values were different[r] ...

8

Transient elastography for assessing and monitoring of liver steatosis and fibrosis

Transient elastography for assessing and monitoring of liver steatosis and fibrosis

...  These can be simultaneously and non-invasively assessed by the combination of transient elastography and bioelectrical impedance analysis 4.3. Introduction Non-alcoholic fatty liver disease (NAFLD) ...

153

Dual-Probe Shear Wave Elastography in a Transversely Isotropic Phantom

Dual-Probe Shear Wave Elastography in a Transversely Isotropic Phantom

... Wave Elastography, we could not find any study on the dual-probe set-up hence it was not possible to compare the technique developed in this thesis with other ...

102

Show all 5372 documents...

Related subjects