• No results found

UV disinfection

CFD Simulation of UV Disinfection Reactor for Applesauce with a Low UV Absorption Coefficient

CFD Simulation of UV Disinfection Reactor for Applesauce with a Low UV Absorption Coefficient

... The initial validation case involved disinfecting water using a UV reactor. In this step, the flow field and velocity profile were obtained by solving RANS equations (Eqs.1 and 2) with proper boundary conditions. ...

14

A Computational Study of UV disinfection performance within a naturally ventilated hospital ward

A Computational Study of UV disinfection performance within a naturally ventilated hospital ward

... A numerical study of natural cross-ventilation applied to a six-bed Nightingale ward was investigated. A series of fifty simulations were carried out to investigate how the placement of upper-room UV ...

11

Numerical Simulation of UV Disinfection Reators: Impact of Fluence Rate Distribution and Turbulence Modeling

Numerical Simulation of UV Disinfection Reators: Impact of Fluence Rate Distribution and Turbulence Modeling

... higher UV light intensity than point 14 in the actinometer measurement, it is likely that the disagreement between numerical and experimental results was caused by the experimental error at point ...the UV ...

135

Experimental and Theoretical Study of a UV Disinfection System for Water Treatment

Experimental and Theoretical Study of a UV Disinfection System for Water Treatment

... LIST OF FIGURES 13 Figure 1.1 Light Spectrum Figure 1 .2 The photochemical Figure 1.3 Organism Figure 1 .4 Test result response dimerization 15 to UV 17 22 summary Figure 2.1 Typical tra[r] ...

114

Computational fluid dynamics and experimental studies of an energy-efficient UV disinfection system for water treatment

Computational fluid dynamics and experimental studies of an energy-efficient UV disinfection system for water treatment

... LIST OF FIGURES Figure 2.1: UV Light Effects on Dna of Microorganisms 9 Figure 2.2: Photochemical Dimerization Process 9 Figure 2.3: UV Photochemical Process 10 Figure 2.4: Basic UV Irra[r] ...

181

1-s2.0-S1473309918302780-main.pdf

1-s2.0-S1473309918302780-main.pdf

... Enhanced disinfection strategies might decrease the risk of transmission of multidrug-resistant organisms through the hospital environment, but supportive evidence is limited to single-centre, quasi-experimental ...

9

Overview of Water Disinfection by UV Technology – A Review

Overview of Water Disinfection by UV Technology – A Review

... of disinfection of water are not so effective and there are problems associated with the usage of very expensive instruments and ...solar disinfection (SODIS), and ceramic filters. Disinfection using ...

7

Levels of Norovirus and E  coli in Untreated, Biologically Treated and UV Disinfected Sewage Effluent Discharged to a Shellfish Water

Levels of Norovirus and E coli in Untreated, Biologically Treated and UV Disinfected Sewage Effluent Discharged to a Shellfish Water

... of UV disinfection on NoV ...applied UV dose suggest that this parame- ter is critically important in terms of effectiveness of NoV removal and that higher doses will significantly assist NoV ...

5

Evaluating a novel UV device for wastewater disinfection : a thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering in Environmental Technology and Sustainable Energy at Massey University, Manawatu Campus, Palme

Evaluating a novel UV device for wastewater disinfection : a thesis presented in partial fulfilment of the requirements for the degree of Master of Engineering in Environmental Technology and Sustainable Energy at Massey University, Manawatu Campus, Palmerston North, New Zealand

... greater UV dose (e.g. point B; high UV intensity and long exposure time) than the fluid flowing further from the quartz sleeve ...low UV intensity and short exposure time). This introduces variations ...

224

Investigating the Effectiveness of Ultraviolet (UV) Water Purification as Replacement of Chlorine Disinfection in Domestic Water Supply

Investigating the Effectiveness of Ultraviolet (UV) Water Purification as Replacement of Chlorine Disinfection in Domestic Water Supply

... Simultaneously, raw water from the same sampled well, was allowed, in the first instance without pre- filtration, and secondly, with filtration, to pass through a pipe into the attached ultraviolet (UV) inlet ...

7

Electro-disinfection of Ballast Water

Electro-disinfection of Ballast Water

... of UV disinfection potential depends on the UV light dose and the amount of turbidity in the water (Perrins et ...utilizing UV light; the results were three to four log reductions on cultured ...

96

Numerical Optimization and Experimental Validation of a Continuous Flow Point-of-Use UV-LED Disinfection Reactor using Computational Fluid Dynamics.

Numerical Optimization and Experimental Validation of a Continuous Flow Point-of-Use UV-LED Disinfection Reactor using Computational Fluid Dynamics.

... treatment disinfection has become increasingly popular due to its ability to inactivate chlorine-resistant microorganisms without the production of known disinfection ...used UV disinfection ...

142

Ultraviolet Radiation for Microorganism Inactivation in Wastewater

Ultraviolet Radiation for Microorganism Inactivation in Wastewater

... quently, UV disinfection has gained widespread use for municipal wastewater, and more recently, interest in us- ing UV for water reuse applications has increased ...[3]. UV disinfection ...

9

Disinfection of Low UV Transmittance Fluids: Fundamentals and Applications

Disinfection of Low UV Transmittance Fluids: Fundamentals and Applications

... All UV disinfection systems need validation to ensure their inactivation performances meet the regulation ...simplified UV dose ...the UV sensitivity of the type of microorganisms used in the ...

177

Disinfection Water Wells and Sterilization

Disinfection Water Wells and Sterilization

... Extended pumping normally clears the water of turbidity, and shown the turbidity of well water after steriliza- tion is quite low 0.21, and Hypochlorite acid (HOCL) will form in waters ranging from PH 6.5 - 7.79. As the ...

9

Studies on the biochemistry of disinfection by monochloramine

Studies on the biochemistry of disinfection by monochloramine

... recovery of monochloramine-treated cells in the presence of excess thiol compounds or thiosulfate; b the relative reactivities between monochloramine and selected organic compounds; and [r] ...

285

Ozone Treatment of Municipal Wastewater Effluent for Oxidation of Emerging Contaminants and Disinfection

Ozone Treatment of Municipal Wastewater Effluent for Oxidation of Emerging Contaminants and Disinfection

... for disinfection has been studied and is being considered as a special circumstance for the primary treated wastewater effluent in the City of ...on disinfection and oxidation of CECs using ozone for ...

249

Wastewater Disinfection with HYDROFLOW Technology

Wastewater Disinfection with HYDROFLOW Technology

... wastewater disinfection method, there are serious safety concerns and ecological problems associated with its ...wastewater disinfection, as an alternative to ...the disinfection efficiency and to ...

51

AN INVESTIGATION OF THE ACTIVATION OF MULTI-COLOUR CHANGING
PHOTOCHROMIC TEXTILES

AN INVESTIGATION OF THE ACTIVATION OF MULTI-COLOUR CHANGING PHOTOCHROMIC TEXTILES

... yapay UV ışıklar ve SMD UV LED'ler olmak üzere üç farklı aktivasyon yöntemi incelenmiş ve bu aktivasyon yöntemlerinin kontrol edilebilir çoklu renk değiştiren fotokromik etkilerin uyarılması için kullanım ...

14

No evidence for UV-based nest-site selection in sticklebacks

No evidence for UV-based nest-site selection in sticklebacks

... the UV(+) and UV(-) filters, we conducted a control exper- iment to test whether nest-site choice is influenced by a difference in ...the UV(+) and UV(-) filters were replaced by two neutral ...

7

Show all 3555 documents...

Related subjects