• No results found

Whole-cell patch-clamp recording experiments

Properties of the Nucleo-Olivary Pathway: An In Vivo Whole-Cell Patch Clamp Study

Properties of the Nucleo-Olivary Pathway: An In Vivo Whole-Cell Patch Clamp Study

... the cell to generate the rebound de- ...single cell level, are proportional to the duration of the GABAergic inhibition: short IPSPs are followed by a short decay in phase-match, whereas long IPSP is ...

11

Automatic tracking of cells for video microscopy in patch clamp experiments

Automatic tracking of cells for video microscopy in patch clamp experiments

... of cell types in the patch-clamp laboratory ...different cell types can be purchased from commercial or public organisations and these animals are extremely important tools in modern ...

14

Whole-Cell Patch Clamp Investigations on Rapid Synaptic Scaling of Mouse CA1 Pyramidal Neurons under Optogenetic Stimulation

Whole-Cell Patch Clamp Investigations on Rapid Synaptic Scaling of Mouse CA1 Pyramidal Neurons under Optogenetic Stimulation

... en presynaptisk cell vars axon möter dendriten hos en postsynaptisk cell. Hjärncellen använder dendriterna för att ”lyssna” (ta emot signalinput) och axonen för att ”prata” (skapa signaloutput) – ”trädet” ...

47

Characterization of intracortical synaptic connections in the mouse anterior cingulate cortex using dual patch clamp recording

Characterization of intracortical synaptic connections in the mouse anterior cingulate cortex using dual patch clamp recording

... The anterior cingulate cortex (ACC) is involved in sensory, cognitive, and executive functions. Studies of synaptic transmission and plasticity in the ACC provide an understanding of basic cellular and molecular ...

12

Planar Patch Clamp: Advances in Electrophysiology

Planar Patch Clamp: Advances in Electrophysiology

... the cell is positioned auto- matically by application of suction ...a cell has been sealed to the chip and whether the parameters correspond to the cell-attached or the whole-cell ...

12

Errors in the measurement of voltage-activated ion channels in cell-attached patch-clamp recordings

Errors in the measurement of voltage-activated ion channels in cell-attached patch-clamp recordings

... as whole- cell patch-clamp recordings do not accurately describe the macro- scopic properties of voltage-activated channels 7–9 ...using cell-attached and cell- free ...

9

GABA-mediated inhibitory postsynaptic currents recorded in rat hippocampal slices using intracellular and patch clamp recording techniques

GABA-mediated inhibitory postsynaptic currents recorded in rat hippocampal slices using intracellular and patch clamp recording techniques

... voltage clamp and the patch clamp techniques, the range of amplitudes was also very ...the patch clamp technique, the range of amplitudes was usually less than 10 - 100 pA with rare ...

118

EPC 10 USB Patch Clamp Amplifier family

EPC 10 USB Patch Clamp Amplifier family

... Quadro Patch Clamp Amplifier The EPC 10 USB Double, Triple and Quadro amplifiers are the optimal instruments for performing multiple patch/cell ...

12

A patch-clamp study of native and recombinant glutamate receptors

A patch-clamp study of native and recombinant glutamate receptors

... from whole-cell experiments, that kainate failed to desensitise AMPA ...However, whole-cell responses afford a limited resolution and AMPA receptors were found to desensitise (albeit ...

159

Automated Patch Clamp in Cystic Fibrosis Drug Discovery

Automated Patch Clamp in Cystic Fibrosis Drug Discovery

... 3. Stable and high-quality recordings, enabling detection of low-efficacy compounds. Together, these criteria required a system capable of routinely achieving GΩ seals, and disqualified APC plat- forms that required seal ...

8

In vivo whole-cell recording with high success rate in anaesthetized and awake mammalian brains

In vivo whole-cell recording with high success rate in anaesthetized and awake mammalian brains

... vivo, Whole-cell recording, Amphotericin, Anaesthetized, Awake, Cortex, Hippocampus Introduction Whole-cell patch-clamp recording is an important neuro- science ...

14

Dual patch voltage clamp study of low membrane resistance astrocytes in situ

Dual patch voltage clamp study of low membrane resistance astrocytes in situ

... Dual patch recording was once considered to be a time- consuming technique which required considerable ...this recording mode can be performed rou- tinely, studying 3–8 cells in a 6-hour experimental ...

12

ISOLATION OF EPIDERMAL CELL PAIRS FROM AN INSECT, TENEBRIO MOLITOR, FOR DUAL WHOLE CELL RECORDING OF LARGE CONDUCTANCE GAP JUNCTIONAL CHANNELS

ISOLATION OF EPIDERMAL CELL PAIRS FROM AN INSECT, TENEBRIO MOLITOR, FOR DUAL WHOLE CELL RECORDING OF LARGE CONDUCTANCE GAP JUNCTIONAL CHANNELS

... junctions, patch clamp, single channels, octanol, Tenebrio ...EPIDERMAL CELL PAIRS FROM AN INSECT, TENEBRIO MOLITOR, FOR DUAL WHOLE-CELL RECORDING OF LARGE-CONDUCTANCE ...

7

Electrophysiological analysis of mammalian cells expressing hERG using automated 384-well-patch-clamp

Electrophysiological analysis of mammalian cells expressing hERG using automated 384-well-patch-clamp

... automated patch-clamp system, the following procedures were performed ...384-well patch-clamp chip, and entrapped in the holes of the wells by an automatic- ally applied ...standard ...

6

Deep-Channel uses deep neural networks to detect single-molecule events from patch-clamp data

Deep-Channel uses deep neural networks to detect single-molecule events from patch-clamp data

... some experiments with very noisy data, threshold crossing open probability estimations were over 100% out and SKM detected only near half of the open events (~50% ...data recording in under 4 s of ...

10

Patch clamp analysis of voltage activated and chemically activated currents in the vomeronasal organ of Sternotherus odoratus (stinkpot/musk turtle)

Patch clamp analysis of voltage activated and chemically activated currents in the vomeronasal organ of Sternotherus odoratus (stinkpot/musk turtle)

... The presence of these putative signal-transduction proteins supports their involvement in encoding chemical information, but the functional role of these proteins remains incompletely determined. Ultimately, the ...

14

A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells

A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells

... In patch clamp experiments the biological cells are exposed to fast changing environmental stimuli created by an open perfusion ...the cell is recorded through an electrode placed in the ...

14

NOISE PERFORMANCE OF A PATCH VOLTAGE CLAMP AND A BILAYER VOLTAGE CLAMP

NOISE PERFORMANCE OF A PATCH VOLTAGE CLAMP AND A BILAYER VOLTAGE CLAMP

... • Seal Noise: Although the precise physical nature of the so-called “gigaseal” is not completely understood, its importance to high resolution patch clamping in undeniable. The seal resistance is in parallel with ...

20

Stress clamp experiments on multicellular tumor spheroids

Stress clamp experiments on multicellular tumor spheroids

... PACS numbers: 87.19.xj,87.19.R-,87.55.Gh Cancer progression occurs in several stages. In the case of carcinomas, which are cancers of epithelial cells, the primary tumor grows locally, until some cells invade the ...

6

Automated Patch Clamp System Software Release Notes

Automated Patch Clamp System Software Release Notes

... There is now a warning message at the beginning of the experiment reminding the user to manually place a cellboat with cells on the process deck. Keep in mind that if the cell boat is present and has not been ...

41

Show all 10000 documents...

Related subjects