• No results found

[PDF] Top 20 Comparison of micro ID and API 20E in rapid identification of Enterobacteriaceae

Has 10000 "Comparison of micro ID and API 20E in rapid identification of Enterobacteriaceae" found on our website. Below are the top 20 most common "Comparison of micro ID and API 20E in rapid identification of Enterobacteriaceae".

Comparison of micro ID and API 20E in rapid identification of Enterobacteriaceae

Comparison of micro ID and API 20E in rapid identification of Enterobacteriaceae

... The degree to which a same-day system does not require supplemental overnight testing is a measure of its same-day applicability, and identifications which require additional tests in th[r] ... See full document

6

Rapid identification of Enterobacteriaceae with the micro ID system versus API 20E and conventional media

Rapid identification of Enterobacteriaceae with the micro ID system versus API 20E and conventional media

... pneumoniae gave a weakly positive urea test and was properly identified; if the urease test were read as negative it would have been misidentified as Enterobacter species.. We concluded [r] ... See full document

6

Time motion and cost comparison study of micro ID, API 20E, and conventional biochemical testing in identification of Enterobacteriaceae

Time motion and cost comparison study of micro ID, API 20E, and conventional biochemical testing in identification of Enterobacteriaceae

... A total of 730 Enterobacteriaceae strains isolated from 567 cultures were evaluated by a rapid kit method Micro-ID; General Diagnostics, Morris Plains, N.J.; 4 h, an overnight incubation[r] ... See full document

6

Parallel comparison of accuracy of API 20E, Vitek GNI, MicroScan Walk/Away Rapid ID, and Becton Dickinson Cobas Micro ID E/NF for identification of members of the family Enterobacteriaceae and common gram negative, non glucose fermenting bacilli

Parallel comparison of accuracy of API 20E, Vitek GNI, MicroScan Walk/Away Rapid ID, and Becton Dickinson Cobas Micro ID E/NF for identification of members of the family Enterobacteriaceae and common gram negative, non glucose fermenting bacilli

... We compared the API 20E 21 h API; bioMerieux Vitek, Hazelwood, Mo., the Vitek GNI card 4 to 18 h Vitek; bioMerieux Vitek, the identification portion of the MicroScan Walk/Away Rapid Neg [r] ... See full document

5

Comparison of Micro ID, API 20E, and Conventional Media Systems in Identification of Enterobacteriaceae

Comparison of Micro ID, API 20E, and Conventional Media Systems in Identification of Enterobacteriaceae

... and conventional biochemical tube media, we found that the Micro-ID and the API 20E systems gave a 90% identification correlation when each was compared with the conventional tube media.[r] ... See full document

7

The comparison of PCR technique and API-20E kit with the conventional biomedical methods for the identification of Salmonella species in laboratory

The comparison of PCR technique and API-20E kit with the conventional biomedical methods for the identification of Salmonella species in laboratory

... S. Comparison of CHROM agar Salmonella medium and Xylose-Lysine-Desoxycholote agar and Salmonella-Shigella agar, for isolation of Salmonella strains from stool ... See full document

8

Identification of Enterobacteriaceae in frozen microdilution trays prepared by Micro Media Systems

Identification of Enterobacteriaceae in frozen microdilution trays prepared by Micro Media Systems

... Isolates misidentified by API 20E strips or by MMS Enteric Quad Panels compared to conventional test methods Identification as obtained from: Conventional tests.. MMS Quad traysb.[r] ... See full document

5

Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram negative bacilli

Comparison of Crystal Enteric/Nonfermenter system, API 20E system, and Vitek AutoMicrobic system for identification of gram negative bacilli

... Md.), API 20E (API; bioMe ´rieux Vitek, ...family Enterobacteriaceae and 131 nonenteric ...testing, API, Crystal, and Vitek correctly identified to the genus and species level 505 ... See full document

7

Radiation Response (Low Dose Gamma Radiation) of Members of the Enterobacteriaceae in Dry Fruiting Bodies of Pleurotus ostreatus and Their Identification Using API 20E System

Radiation Response (Low Dose Gamma Radiation) of Members of the Enterobacteriaceae in Dry Fruiting Bodies of Pleurotus ostreatus and Their Identification Using API 20E System

... Members of the Enterobacteriaceae are generally facultative anaerobes, gram negative, non-spore formers. Most of these organisms are pathogenic, while others produce toxins responsible for food intoxication 1 . ... See full document

5

Rapid Identification of Enterobacteriaceae by Using Noncommercial Micro Tests in Conjunction with API 20E Profile Data

Rapid Identification of Enterobacteriaceae by Using Noncommercial Micro Tests in Conjunction with API 20E Profile Data

... Base media were as follows: 1, peptone meat extract agar; 2, Moeller amino acid decarboxylase medium; 3, Simmons citrate agar; 4, Kligler iron agar; 5, Christensen urea medium; 6, 0.5% w[r] ... See full document

5

Clinical Evaluation of the MICRO ID, API 20E, and Conventional Media Systems for Identification of Enterobacteriaceae

Clinical Evaluation of the MICRO ID, API 20E, and Conventional Media Systems for Identification of Enterobacteriaceae

... Using the MICRO-ID computer identification manual September 1978 edition, the isolate was given one of the following five designations: i identified to genus and species, ii identified t[r] ... See full document

7

Correlation studies of entero set 20, API 20E and conventional media systems for Enterobacteriaceae identification

Correlation studies of entero set 20, API 20E and conventional media systems for Enterobacteriaceae identification

... A comparison of the common reactions among the various systems showed that the citrate test was the least accurate of all of the tests performed.. API performed better in the glucose and[r] ... See full document

6

Serratia ficaria: a Misidentified or Unidentified Rare Cause of Human Infections in Fig Tree Culture Zones

Serratia ficaria: a Misidentified or Unidentified Rare Cause of Human Infections in Fig Tree Culture Zones

... the API 20E database, 100 and 92% of ...the API 20E citrate ...With ID 32E strips, a pos- sible misidentification is between ... See full document

7

Rapid biochemical characterization of Haemophilus species by using the micro ID

Rapid biochemical characterization of Haemophilus species by using the micro ID

... classification and biotyping of HaemophilusNot all of the biochemical tests contained in the Micro- nitrate reductase, indole production, ornithine ID are useful for the classification o[r] ... See full document

5

Evaluation of the API 20E system for identification of nonfermentative Gram negative bacteria

Evaluation of the API 20E system for identification of nonfermentative Gram negative bacteria

... The API 20E system for Enterobacteriaceae, recently broadened to include identification of nonfermentative gram-negative bacteria, was evaluated and compared with the conventional method[r] ... See full document

7

Identification of Pasteurella multocida and Pasteurella haemolytica by API 20E, Minitek, and Oxi/Ferm systems

Identification of Pasteurella multocida and Pasteurella haemolytica by API 20E, Minitek, and Oxi/Ferm systems

... haemolytica DISCUSSION are listed as 100% positive for xylose in the data The results obtained from the rapid identifi- base of the Minitek system; however, in this cation systems includ[r] ... See full document

5

Comparison of PRAS II, RapID ANA, and API 20A systems for identification of anaerobic bacteria

Comparison of PRAS II, RapID ANA, and API 20A systems for identification of anaerobic bacteria

... Of 11 organisms identified by PRAS Il correct to genus only, 9 were incorrectly identified at the species level within the proper genus, and 2 were assigned genus level identifications o[r] ... See full document

5

Helcococcus ovis, an Emerging Pathogen in Bovine Valvular Endocarditis

Helcococcus ovis, an Emerging Pathogen in Bovine Valvular Endocarditis

... the API rapid ID 32 Strep, API ZYM, and Rosco Diatabs systems, incongruent results were obtained for alkaline phosphatase, ␤ -galactosidase, ␤ -glucuronidase, and leucine aminopeptidase ...the ... See full document

5

Integrated Detection of Extended Spectrum Beta Lactam Resistance by DNA Microarray Based Genotyping of TEM, SHV, and CTX M Genes

Integrated Detection of Extended Spectrum Beta Lactam Resistance by DNA Microarray Based Genotyping of TEM, SHV, and CTX M Genes

... Species identification was carried out with the API 20NE system (bioMe ´rieux, Marcy l’Etoile, France) or the Gram-negative identification card GN on a Vitek 2XL ... See full document

12

Rapid identification of Enterobacteriaceae from blood cultures with the Micro ID system

Rapid identification of Enterobacteriaceae from blood cultures with the Micro ID system

... Where the Micro-ID identification manual yielded two or more species as a possible identification, it listed a series of biochemical reactions to separate the choices; in each instance, [r] ... See full document

5

Show all 10000 documents...