Has 10000 "Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA" found on our website. Below are the top 20 most common "Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA".
Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA
... the Abbott RealTime HCV viral load ...The Abbott RealTime HCV viral load system is a closed system post- RT-PCR, and consequently, the generated amplicon will never be released in the ... See full document
6
Impact of the New Abbott mPLUS Feature on Clinical Laboratory Efficiencies of Abbott RealTime Assays for Detection of HIV 1, Hepatitis C Virus, Hepatitis B Virus, Chlamydia trachomatis, and Neisseria gonorrhoeae
... m2000 RealTime assay conditions. HIV-1-, HCV-, and HBV-positive samples were obtained from either PromedDx (Norton, MA) or Northwest Biomedical (Everett, ...each quantitative viral load test ... See full document
5
Multicenter Evaluation of Methods To Quantitate Human Immunodeficiency Virus Type 1 RNA in Seminal Plasma
... HIV RNA assays. Two commercially available assays were com- pared: the Roche AMPLICOR MONITOR assay and the Organon Teknika NASBA HIV-1 QT assay or NucliSens HIV-1 QT assay (hereafter ... See full document
6
Evaluation of Two Commercially Available, Inexpensive Alternative Assays Used for Assessing Viral Load in a Cohort of Human Immunodeficiency Virus Type 1 Subtype C Infected Patients from South Africa
... a quantitative kinetic enzyme-linked immunosorbent assay (ELISA) reader and software (2, 14, 17, 18, 19, 20, ...the virus-encoded enzyme RT, which is packaged together with the viral RNA in the HIV ... See full document
5
Correlation between Human Immunodeficiency Virus Type 1 (HIV 1) RNA Measurements Obtained with Dried Blood Spots and Those Obtained with Plasma by Use of Nuclisens EasyQ HIV 1 and Abbott RealTime HIV Load Tests
... of detection for HIV RNA in DBS by either of the two commercial assays was greater than ...HIV RNA loads greater than 1,000 copies/ml ...of RNA and enhance the sensitivity of viral load ... See full document
6
Impact of Human Immunodeficiency Virus Type 1 (HIV 1) Genetic Diversity on Performance of Four Commercial Viral Load Assays: LCx HIV RNA Quantitative, AMPLICOR HIV 1 MONITOR v1 5, VERSANT HIV 1 RNA 3 0, and NucliSens HIV 1 QT
... Human immunodeficiency virus type 1 (HIV-1) evolution and changing strain distribution present a chal- lenge to nucleic acid-based ...the detection and accurate ... See full document
9
Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV 1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV 1 Test: Workflow, Reliability, and Direct Costs
... Both assays are highly automated and utilize real-time PCR methods to provide broad dynamic ranges and closed-tube amplification-detection formats that decrease hands-on time requirements and reduce the ... See full document
7
Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA
... earlier detection of infection because they directly test for the presence of circulating virus rather than measure the indi- vidual’s antibody response to the ...of detection, serves as an indepen- ... See full document
12
Sensitivity of the Procleix HIV 1/HCV Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA in a High Risk Population
... simultaneous detection of human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) RNA in ...discriminatory assays to ... See full document
5
Evaluation of the Abbott LCx HIV 1 RNA Quantitative, a New Assay for Quantitative Determination of Human Immunodeficiency Virus Type 1 RNA
... cial assays for the measurement of viral load have been devel- oped during the last few years (1, 12, 13, 21), based on three different methods: target amplification by reverse transcription- PCR or by ... See full document
5
Evaluation of the Abbott m2000 RealTime Human Immunodeficiency Virus Type 1 (HIV 1) Assay for HIV Load Monitoring in South Africa Compared to the Roche Cobas AmpliPrep Cobas Amplicor, Roche Cobas AmpliPrep Cobas TaqMan HIV 1, and BioMerieux NucliSENS EasyQ HIV 1 Assays
... existing assays, in that it performs test of 93 samples in one shift (results are reportable in one 8-h ...technology, RealTime HIV-1 re- quires less manual preparation (38) and therefore fewer ... See full document
9
Design and Evaluation of a Human Immunodeficiency Virus Type 1 RNA Assay Using Nucleic Acid Sequence Based Amplification Technology Able To Quantify Both Group M and O Viruses by Using the Long Terminal Repeat as Target
... direct detection of HIV-1 RNA by hybridization with labeled probes ...Amplicor assays were developed with re- agents derived from HIV-1 subtype B, but they can detect most group M ... See full document
6
Prevalence and Clinical study of Hepatitis B in Antenatal Women
... chronic hepatitis B (precore mutant) emerges as the predominant species during the course of typical HBV infection with wild-type virus and is selected during the immune clearance phase (HBeAg ... See full document
102
Differing Patterns of Liver Disease Progression and Hepatitis C Virus (HCV) Quasispecies Evolution in Children Vertically Coinfected with HCV and Human Immunodeficiency Virus Type 1
... by 6 years of age (Fig. 1D). Oral candidiasis was a recurrent finding, while additional drug combinations failed to control HIV-1 replication (Fig. 1E). Elevations of ALT and AST levels were observed in three ... See full document
5
Molecular Detection of HGV RNA in Chronic Hepatitis Patients from Afzalipoor General Hospital in Kerman, Iran
... this virus have been proposed based on the sequence analysis of the 5´ GBV- noncoding region 5´ (NCR) or E2 ...fulminant hepatitis due to HGV infection have been reported, but it remains unclear whether the ... See full document
7
HIV Load Testing with Small Samples of Whole Blood
... in 1 ml of ...the detection of viral particles and/or HIV-1 RNA not only in asso- ciation with platelets (5, 28, 40), monocytes (44), and resting and activated CD4 ⫹ cells under prolonged ... See full document
7
Evaluation of the Abbott RealTime MTB and RealTime MTB INH/RIF Assays for Direct Detection of Mycobacterium tuberculosis Complex and Resistance Markers in Respiratory and Extrapulmonary Specimens
... PCR assays that allow for the fast and accurate detection of Mycobacterium tuberculosis complex (MTBC) DNA directly in clinical specimens, have become an indispensable tool in TB diag- nostics over the last ... See full document
6
Quantitative Detection of Plasma Human Immunodeficiency Virus Type 2 Subtype A RNA by the Nuclisens EasyQ Assay (Version 1 1)
... HIV-2 RNA. RNA was extracted from each sample by using the Nuclisens extractor (bioMe ´rieux), and the Nuclisens EasyQ (version ...HIV-2 RNA molecules, following the manufacturer’s ...real-time ... See full document
5
Multicenter Evaluation of the VERSANT HCV RNA Qualitative Assay for Detection of Hepatitis C Virus RNA
... Qualitative hepatitis C virus (HCV) RNA assays play a key role in both the diagnosis and monitoring of HCV ...HCV RNA assays detect viral genomes and therefore can both ... See full document
6
Comparative performance of the new Aptima HIV-1 Quant Dx assay with three commercial PCR-based HIV-1 RNA quantitation assays
... of detection, with virological failure as the inability to achieve or maintain HIV-1 RNA load below 200 copies/ml ...HIV-1 RNA quantitation impact on patient ... See full document
7