The Authority menu contains options for the following Authority Levels:
♦ Grand Master: There can be only one Grand Master in the system, and the Grand Master can perform all the available user functions.
The Grand Master code is designated as Code 00. NOTE:
The Engineer can define that the Grand Master has the ability to change the authority level and allowed partitions for users. Refer to Grand Master Authority/Partition (Quick Keys [1] [2] [27]), page 4-9.)
♦ Manager: There can be only one Manager Code in the system. The Manager Code is designated only as Code 01. The Manager can change all User Codes except that of the Grand Master. The Manager has access to all of the function listed above, apart from the following:
Changing the Grand Master Code Performing Walk Testing
♦ Master: There are no restrictions in the number of Master Codes (as long as they do not exceed the number of codes remaining in the system). The Master has access to all the Manager's privileges, with the following restrictions:
Restricted to assigning and changing User Codes belonging to those with Authority Levels of Master and below (User, Arm Only, and Maid) Restricted access to designated partitions
♦ User: There are no restrictions in the number of User Codes (as long as they do not exceed the number of codes remaining in the system). The User has access to the following:
Administering selected system tests, except Walk Testing
♦ Set Only: There are no restrictions in the number of Set Only Codes (as long as they don't exceed the number of codes remaining in the system). Set Only Codes are useful for workers who arrive when the premises are already open, but because they are last to leave, they're given the responsibility to close the premises and arm the system. The users with Set Only Codes have access for Setting one or more partitions.
♦ Cleaner: The Cleaner Code is a temporary code, which is to be immediately deleted from the system as soon as it is used to set. This code is typically used for cleaners, home attendants, and repairmen who must enter the premises before the owner(s) arrive. These codes are used as follows:
For one-time setting in one or more partitions
If first used to unset the system, the Cleaner Code may be used once for subsequent setting
♦ PO Only: Typically used to enable the operation of a device controlled by a Programmable Output (meaning a door and so on). These codes are used only to operate an output.
♦ User Un-Omit: This user has access to all the User's privileges apart from omitting zones.
44 22
Codes: Partition
Default: Partition 1
The Partition menu enables you to assign the partition(s) in which all User Codes (except for the Grand Master) will operate.
¾
To access the Partition menu:1. Access the Codes menu, as described on page 4-43. 2. From the Codes menu, press [2] to access the Partition menu.
3. Enter the appropriate two-digit User Code and press . The following display appears: P=123 C=01
Y..
P=123 C=01 Y..
4. Use the or keys to position the cursor under the digit the represents the partition you want to assign the code to.
5. Designate the partition(s) for which the designated user can have access by using the
[1 to 3] keys.
NOTE:
The "non-partitioned" system is assumed to be using Partition 1.
6. Press to access another User Code.
7. Repeat steps 2 to 6, as required, until all User Codes used in the system are assigned to the appropriate partition(s).
Default: 1234
The Grand Master menu enables the owner to set the Grand Master Code. NOTE:
The Grand Master code can also be changed in the User menu (by the Grand Master).
The Grand Master is the highest Authority Level. Refer to Authority Levels, page 4-46, for additional details about other authority levels.
¾
To access the Grand Master menu:1. Access the Codes menu, as described on page 4-43.
2. From the Codes menu, press [3] to access the Grand Master menu. The following display appears:
Grand Master **** Grand Master
****
3. Enter a Grand Master Code using the keypad's [0 to 9] keys and then press . 4. Press the key to return to the previous level.
NOTE:
The Grand Master, Engineer and the Sub-Engineer can enter and change other level codes, but they cannot see the code. The message [****] is displayed instead of the code.
44 44
Codes: Engineer
Default: 0133
The Engineer Code provides access to the Engineer Programming menu, allowing modification of all system parameters. The default Engineer Code is:[0][1][3][3]
RISCO recommends changing the factory default to a new code unique to the Main Panel and/or to the alarm company personnel, as described in the procedure below.
¾
To change the Engineer code:1. Access the Codes menu, as described on page 4-43.
2. From the Codes menu, press [4] to access the Engineer Code menu. The following display appears:
Engineer: Code:0133 Engineer: Code:0133
3. Enter the new code, using the keypad's [0 to 9] keys and press . 4. Confirm your selection by re-entering the same code and pressing . 5. Press the key to return to the previous level.
Default: 0233
The Sub-Engineer Code allows limited access to selected parameters from the Engineer Programming menu. The default Sub-Engineer Code is: [0][2][3][3] We recommend changing the factory default to a code unique to the Main Panel and/or to those who may serve as sub-installers in your alarm company, as described in the following procedure. The limitations of the Sub Engineer are as follows (The display of the LCD screen will be “Disabled” for each restricted option):
♦ System menu: He cannot define the Default Enable / Disable parameter.
♦ Code Maintenance menu: He cannot change the Engineer code.
♦ Digicom Menu: He cannot change the ARC telephone numbers, Account numbers, Communication format, Access and ID parameters, and Remote Split menus. In the Controls sub menu he cannot change the ARC Enable and UD Enable parameters. In the Parameters sub menu he can define only the FM Retries, and windowing options.
♦ Report Codes: He cannot define any reported codes parameters.
¾
To access the Sub-Engineer code menu:1. Access the Codes menu, as described on page 4-43.
2. From the Codes menu, press [5] to access the Sub-Engineer menu. The following display appears:
Sub-Engineer: Code:0233 Sub-Engineer: Code:0233
3. Type in the new code using the keypad's [0 to 9] keys and press . 4. Press the key to return to the previous level.