A map file could not be accessed at the specified location.

Meaning: This message can occur if you do not have access to the Symbols share while trying to run the Compare Design Basis command.

Recovery: Ask your administrator to grant you access to the Symbols share and to the map file (SP3DToEFWClassMap.xml) on that share that is used in the Compare Design Basis command.

A problem occurred while claiming the objects in SmartPlant Foundation. Do you want to release these claims in SmartPlant 3D now to avoid an inconsistent state?

Meaning: The claim operation was not successful. Objects are shown as claimed in SmartPlant 3D, but not in SmartPlant Foundation.

Recovery: If you click Yes, the software calls the Release Claim

command for the remaining objects in the select set. This sets the objects in the select set to as-built, whether or not they were in the as-built or not assigned to any project before the Claim command began. If you click No, the Claim command ends. The objects remain claimed in SmartPlant 3D, but not in SmartPlant Foundation. This is an incorrect state for the objects.

You will need to run the Claim command again on these objects to update their status.

A problem occurred while releasing claims on these objects in SmartPlant Foundation. Do you want to claim these objects back to the active project in SmartPlant 3D now to avoid an inconsistent state?

Meaning: The release claim operation was not successful.

Recovery: If you click Yes, the software claims the objects in the select set back to the active project. If you click No, the Release Claim command ends.

All occurrences of the same type and purpose with a given project must have the same setting for the Exclusive property.

Meaning: All WBS items in a project that have the same type and purpose must all have the Exclusive property set to True, or must all have the Exclusive property set to False. When creating or modifying a WBS item, you choose a type, purpose, and exclusive setting.

Recovery: Specify a different type, purpose, or exclusive setting for the WBS item.

Meaning: You have selected a weld, gasket, washer, nut, or bolt, and tried to delete it.

Recovery: You must delete the parent feature if you want to delete a connection item.

Analytical model "XXX" has already been exported. Return or update the existing model.

Meaning: The analytical model has already been exported. You cannot export multiple analytical models in this version of the software.

Recovery: Update the existing analytical model with changes from the third-party analysis software. After updating, you can then export the analytical model again.

Analytical model could not be exported. Check the status of the analytical model or protections on the file.

Meaning: The software cannot export the analytical model to the CIS file because the analytical model is marked as Approved or is in a permission group that does not allow writing. It is also possible that the CIS file itself is locked from write access by the operating system in some way.

Recovery: Try the following: Change the analytical model status to Working. Change the permission group to one that allow writing. Check the read-only status and ownership of the CIS file in the operating system.

Analytical model could not be imported. Check the status of the analytical model or protections on the file.

Meaning: The software cannot import the analytical model from the CIS file because the analytical model is marked as Approved or is in a permission group that does not allow writing. It is also possible that the CIS file itself is locked from read access by the operating system in some way.

Recovery: Try the following: Change the analytical model status to Working. Change the permission group to one that allow writing. Check the status and ownership of the CIS file in the operating system.

Another part class with that name already exists. Please enter another name.

Meaning: A existing part class has the same name as the one you entered for the part class that you are creating.

Recovery: Enter a unique name for the new part class that is less than 24 characters long.

Assembly Info Rule ProgID cannot be retrieved from the support object.

this assembly. This situation can happen if the program was not registered in the registry or if the program name is misspelled on the worksheet that was bulkloaded into the Catalog database. This error message could appear when you are using the Drop Standard command in the Hangers and Supports task.

Recovery: Review the rules and reference data worksheet that specify the assembly information rule for the standard support.

At least one object must be selected for hyperlink association.

Meaning: There were no objects selected, and you tried to insert a link.

Recovery: Select an object, and then click Insert > Link.

Attributes cannot be retrieved from hanger rule object.

Meaning: The software cannot read the necessary attributes from the catalog when placing a support.

Recovery: There is a problem in the hangers and supports catalog. For example, you may need to update the HS_Systems.xls workbook.