Parameter Description
Name Indicates the name of the currently added scanner.
Type Indicates the type of the currently added device: Scanner. Model Indicates the model of a scanner. Note that PCTEL EX scanners
support multi-mode tests and multi-band tests.
For the scanner models supported by the Probe, see Scanner. COM port Indicates the actual COM port used by the scanner after the scanner
is connected to the PC.
You can view the actual port number of the scanner under the Ports (COM & LPT) node in the Device Manager window.
Parameter Description
Band Indicates the frequency band that is supported by the connected scanner. l GSM GSM850 (869 MHz to 894 MHz), E-GSM (925 MHz to 960 MHz), DCS1800 (1805 MHz to 1880 MHz), and PCS 1900 (1930 MHz to 1990 MHz). l WCDMA Band I DL (2110.0 MHz to 2170.0 MHz), Band I UL (1920.0 MHz to 1980.0 MHz), Band II (1930.0 MHz to 1990.0 MHz), Band III (1805.0 MHz to 1880.0 MHz), Band IV (2110.0 MHz to 2155.0 MHz), Band V (869.0 MHz to 894.0 MHz), and Band VIII (925.0 MHz to 960.0 MHz).
l CDMA
Band 0 (869.61 MHz to 893.40 MHz), Band 0 (860.64 MHz to 874.38 MHz), Band 1 (1930.65 MHz to 1989.35 MHz), Band 3 (860.6375 MHz to 869.3625 MHz), and BAND 5 (461.95 MHz to 466.85 MHz).
l WiMAX
2.5 GHz (2498.50 MHz to 2687.50 MHz) and 3.5 GHz (3402.50 MHz to 3597.50 MHz).
Instance Indicates the interface number that is used by the scanner of the Anritsu ML874X series (for example, ML8740 or ML8742) after the scanner is connected to the PC. You need to select an interface number that is not used by another scanner.
If the scanner of the Anritsu ML874X series is not connected to the PC, select Not Configure.
1394 Indicates the interface number that is used by the scanner of the Rohde & Schwarz TSMX series after the scanner is connected to the PC. You need to select an interface number that is not used by another scanner.
If only one TSMX scanner is connected, select 1. If the scanner of the Rohde & Schwarz TSMX series is not connected to the PC, select Not Configure.
12 Interface Reference of the Probe
GENEX Probe User Guide
12-24 Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Parameter Description
Adjust antenna Indicates the antenna gain of the scanner. Only the scanners of the PCTel SeeGull LX series and the EX series are supported. You can select either of the following values:
l Disable: not set the antenna gain of the scanner. l Enable: set the antenna gain of the scanner.
If you select Enable, you can set the antenna gain in the displayed Scanner External Antenna Setting dialog box. The Probe may automatically compensate the antenna or cable loss of the scanner.
The default value is Disable.
CAUTION
For the scanner to which an external antenna is connected, you can set the antenna gain as required.
For the scanner to which an external antenna is not connected, if you set the antenna gain, the accuracy of indicators such as the RSSI, RxLev, or RSCP may be affected. Therefore, you are advised to select Disable.
Related Tasks
7.3 Configuring External Devices
12.8 Parameters for Filtering the Original Data
This describes the parameters for filtering the original data in the Filter dialog box. You can refer to these parameters when you configure whether to report or collect the signaling on a test terminal.
Parameter Description
LogCode Displays the name of the data package.
Select Indicates that whether the test terminal reports the data package. Filter Indicates the mode that the Probe adopts to collect data packages:
l No Filter: The Probe collects all the data packages reported by the terminal.
l By Periods: The Probe collects the data packages reported by the terminal periodically.
l All Filter: The Probe does not collect the data packages reported by the terminal.
Interval Indicates the sampling interval. The Probe collects data packets at the sampling intervals set here. Redundant data packets are discarded.
Related Tasks
7.5 Selecting the Data to Be Collected
12.9 Parameters for Configuring the Test Items
This describes the parameters for configuring the test items and attributes of the MS and scanner. You can refer to these parameters when you configure the MS or scanner test plan in the Test Plan Control window.
Parameter Description
Adds the parameters of the test item.
Name Displays the selected test item.
Status Displays the current status of the test item.
l Ready: Indicates the ready status. l Testing: Indicates the testing status. l Finish: Indicates the finish status.
Progress Displays the count for which the test item is performed. The
format is n/N. n indicates the count for which a test item is currently performed and N indicates the total count for which a test item is performed.
Parameters for setting the properties of the added test item.
Property Displays the property name of the test item.
Value Enables you to set values of the Property.
Related Tasks
8.4 Designing Test Plans
12.10 Parameters for Monitoring the Test
This describes the parameters for monitoring the test. During the test or replay, you can refer to these parameters when you query the status and statistics value of each test item in the test plan in the Test Plan Control window.
Parameters for Monitoring the Test
The list for monitoring the test is in the lower pane of the Test Plan Control window to display the status of the test item.
Parameter Description
Time Displays the time for performing the current test item. 12 Interface Reference of the Probe
GENEX Probe User Guide
12-26 Huawei Proprietary and Confidential