Solving problems

In document System x3550. Type 7978 (Page 67-102)

This chapterprovidesbasictroubleshootinginformationto helpyousolvesome common problemsthatmightoccurwhile youaresettinguptheserver.

If youcannotlocateandcorrecttheproblemusingtheinformationinthis chapter, seeAppendixA,“Getting helpandtechnicalassistance,”onpage 73,theIBM ProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CD,andthe“ServerSupport”flowchartinthefrontofthisdocument.

Diagnostic tools overview

Thefollowingtoolsareavailabletohelpyou diagnoseandsolvehardware-related problems:

v POSTbeepcodes

Thepower-onself-test(POST)beepcodesindicatethedetectionof aproblem.

See“POSTbeepcodes”andtheIBMProblemDeterminationandServiceGuide ontheIBMSystemxDocumentationCDfor moreinformation.

v Troubleshootingtables

Thesetableslist problemsymptomsandstepstocorrecttheproblems.See

“Troubleshootingtables”onpage56formore information.

v Lightpathdiagnostics

Uselight pathdiagnosticstodiagnosesystemerrorsquickly.See“Lightpath diagnostics”onpage 68for moreinformation.

v Diagnosticprogramsanderrormessages

Thediagnosticprograms,which arestoredinupgradableread-only memory (ROM)onthesystem board,aretheprimarymethodof testingthemajor componentsof theserver.SeetheIBMProblemDeterminationandService GuideontheIBMSystemxDocumentationCDfor moreinformation.

POST beep codes

POSTemitsonebeeptosignalsuccessfulcompletion.IfPOSTdetectsaproblem duringstartup,otherbeepcodesmightoccur.Usethefollowingbeep code

descriptionsto helpdiagnoseandsolveproblemsthataredetectedduringstartup.

Note: SeetheProblemDeterminationandServiceGuideontheIBMSystemx DocumentationCDfor moreinformationaboutthePOSTbeep codes.

Asingleproblemmightcausemorethanoneerrormessage.Whenthisoccurs, correctthecauseofthefirsterrormessage.Theothererrormessagesusuallywill notoccurthenexttimePOSTruns.

One beep

POSTwascompletedsuccessfullywithoutfinding anyerrors.

One longbeepandtwoshort beeps

Avideoerrorhasoccurred,andtheBIOScannotinitializethemonitor screento displayadditionalinformation.

Otherbeepcodes

SeetheProblemDetermination andServiceGuideontheIBMSystemx DocumentationCDforinformationaboutother beepcodes.

POST error codes

Thefollowingtable providesanabbreviatedlist oftheerrorcodesthatmightappear duringPOST.SeetheIBMProblemDeterminationandServiceGuideontheIBM Systemx DocumentationCDfor moreinformationaboutthePOSTerrorcodes.To check forupdatedtechnicalinformation,completethefollowingsteps.

Note: ChangesaremadeperiodicallytotheIBMWebsite.Theactualprocedure mightvaryslightlyfromwhatisdescribedinthis document.

1. Gotohttp://www.ibm.com/systems/support/.

2. UnderProductsupport,clickSystemx.

3. UnderPopularlinks, clickPublicationslookup.

4. FromtheProductfamilymenu,selectSystemx3550andclick Continue.

Table6.Abbreviatedlistoferrorcodes

Errorcode Description Action

161 Thereal-timeclockbatteryhasfailed. 1. Reseatthebattery.

2. Replacethebatteryorcallforservice.

162 Adeviceconfigurationhaschanged. 1. RuntheConfiguration/SetupUtilityprogram, selectLoadDefaultSettings,andsavethe settings.

2. Makesurethatoptionaldevicesareturnedon andinstalledcorrectly.

163 Thetimeofdayhasnotbeenset. RuntheConfiguration/SetupUtilityprogramandset thedateandtime.

201 Memorytesterror. MakesurethattheDIMMsareinstalledcorrectly.

289 AfailingDIMMwasdisabled. MakesurethattheDIMMsaresupportedbythe serverandthattheyareinstalledcorrectly.

301,303 Keyboardandkeyboardcontroller Makesurethatthekeyboardcableisconnectedand thatnothingisrestingonthekeyboardkeys.

11xx Serialportconfigurationerror. RuntheConfiguration/SetupUtilityprogram,select LoadDefaultSettings,andsavethesettings.

0018xxx PCIdeviceerror 1. MakesurethePCIadaptersandrisercardsare installedcorrectly.

2. RuntheConfiguration/SetupUtilityprogram, selectLoadDefaultSettings,andsavethe settings.

3. RemovethePCIadaptersandrisercards,oneat atime,untiltheproblemisisolated.

00019xxx Microprocessorxisnotfunctioningorfailed thebuilt-inself-test.

Makesurethatmicroprocessorxisinstalledcorrectly.

(Trainedservicetechnicianonly)Iftheproblem remains,replacemicroprocessorx.

01298xxx Dataformicroprocessorx DownloadandinstallthelatestlevelofBIOScode.

I9990305 Operatingsystemnotfound RuntheConfiguration/SetupUtilityprogramtomake surethatabootableoperatingsystemisinstalledon oneormoredevicesthatarelistedinthebootorder.

ServerGuide problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

TheServerGuideSetupand InstallationCDwillnotstart.

1. MakesurethattheserversupportstheServerGuideprogramandhasa startable(bootable)CD-RW/DVDdrive.

2. Ifthestartup(boot)sequencesettingshavebeenchanged,makesurethatthe CD-RW/DVDdriveisfirstinthestartupsequence.

3. IfmorethanoneCD-RW/DVDdriveisinstalled,makesurethatonlyonedrive issetastheprimarydrive.StarttheCDfromtheprimarydrive.

TheServeRAIDprogramcannot viewallinstalleddrives,orthe operatingsystemcannotbe installed.

1. MakesurethattherearenoduplicateIRQassignments.

2. Makesurethattheharddiskdriveisconnectedcorrectly.

3. Makesurethattheharddiskdrivecablesaresecurelyconnected.

Theoperating-system installationprogram continuouslyloops.

Makemorespaceavailableontheharddisk.

TheServerGuideprogramwill notstarttheoperating-system CD.

Makesurethattheoperating-systemCDissupportedbytheServerGuideprogram.

SeetheServerGuideSetupandInstallationCDlabelforalistofsupported operating-systemversions.

Theoperatingsystemcannotbe installed;theoptionisnot available.

Makesurethattheserversupportstheoperatingsystem.Ifitdoes,nologicaldrive isdefined(RAIDservers).RuntheServerGuideprogramandmakesurethatsetup iscomplete.

Troubleshooting tables

Usethetroubleshootingtablesto findsolutionstoproblemsthathaveidentifiable symptoms. SeetheProblemDeterminationandServiceGuideontheIBMSystemx DocumentationCDformoredetailed troubleshootinginformation.Ifyou cannotfind theprobleminthesetables,runthediagnosticprograms (see“Runningthe

diagnostic programs”intheProblemDeterminationandServiceGuide).

If youhavejust addednew softwareora newoptional deviceandtheserverisnot working,completethefollowingstepsbeforeusingthetroubleshootingtables:

1. Check thelightpathdiagnosticsLEDs(see“Lightpathdiagnostics”onpage 68).

2. Removethesoftwareor devicethatyoujustadded.

3. Run thediagnosticteststodeterminewhethertheserverisrunningcorrectly.

4. Reinstall thenewsoftwareornewdevice.

CD-RW/DVD drive problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v

Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

TheCD-RW/DVDdriveisnot

recognized. 1. Makesurethat:

v TheIDEchanneltowhichtheCD-RW/DVDdriveisattached(primary)is enabledintheConfiguration/SetupUtilityprogram.

v Allcablesandjumpersareinstalledcorrectly.

v ThecorrectdevicedriverisinstalledfortheCD-RW/DVDdrive.

2. RuntheCD-RW/DVDdrivediagnosticprograms.

3. Reseatthefollowingcomponents:

a. CD-RW/DVDdrive b. CD-RW/DVDdrivecable

4. Replacethefollowingcomponentsoneatatime,intheordershown,restarting theservereachtime:

a. CD-RW/DVDdrive b. CD-RW/DVDdrivecable

c. (Trainedservicetechnicianonly)Systemboard TheCD-RW/DVDisnotworking

correctly. 1. CleantheCD-RW/DVDdrive.

2. RuntheCD-RW/DVDdrivediagnosticprograms.

3. Reseatthefollowingcomponents:

a. CD-RW/DVDdrive b. CD-RW/DVDdrivecable 4. ReplacetheCD-RW/DVDdrive.

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

TheCD-RW/DVDdrivetrayis

notworking. 1. Makesurethattheserveristurnedon.

2. Inserttheendofastraightenedpaperclipintothemanualtray-release opening.

3. ReseattheCD-RW/DVDdrivecable.

4. ReplacetheCD-RW/DVDdrive.

General problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v

Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

AnLEDisnotworking,ora similarproblemhasoccurred.

IfthepartisaCRU,replaceit.IfthepartisaFRU,thepartmustbereplacedbya trainedservicetechnician.

Hard disk drive problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

Notalldrivesarerecognizedby theharddiskdrivediagnostic test.

Removethedrivethatisindicatedbythediagnostictests;then,runtheharddisk drivediagnostictestagain.Iftheremainingdrivesarerecognized,replacethedrive thatyouremovedwithanewone.

Theserverstopsresponding duringtheharddiskdrive diagnostictest.

Removetheharddiskdrivethatwasbeingtestedwhentheserverstopped responding,andrunthediagnostictestagain.Iftheharddiskdrivediagnostictest runssuccessfully,replacethedrivethatyouremovedwithanewone.

Aharddiskdrivewasnot detectedwhiletheoperating systemwasbeingstarted.

Reseatallharddiskdrivesandcables;then,runtheharddiskdrivediagnostic testsagain.

Aharddiskdrivepassesthe diagnosticFixedDiskTest,but theproblemremains.

RunthediagnosticforSCSIAttachedDisks.

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

Aharddiskdrivethatyouare installingdoesnotfitcorrectlyin thecage.

Makesurethatthetypeofdriveiscorrectforthisserver.

Intermittent problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

Aproblemoccursonly occasionallyandisdifficultto diagnose.

1. Makesurethat:

v Allcablesandcordsareconnectedsecurelytotherearoftheserverand attacheddevices.

v Thereisadequatecoolingairflow.Reducedairflowduetoafailedfanoran internalorexternalobstructioncancausetheservertooverheatandshut down.

2. Checkthesystem-errorlogortheBMClog(see“ErrorLogs”intheProblem DeterminationandServiceGuide).

Iftheproblemremains,callforservice.

Theserverresets(restarts)

occasionally 1. IftheresetoccursduringPOSTandthePOSTwatchdogtimerisenabled(click AdvancedSetup-->BaseboardManagementController(BMC)Setting-->

BMCPostWatchdogintheConfiguration/SetupUtilityprogramtoseethe POSTwatchdogsetting),makesurethatsufficienttimeisallowedinthe watchdogtimeoutvalue(BMCPOSTWatchdogTimeout).SeetheUser’s GuideforinformationaboutthesettingsintheConfiguration/SetupUtility program.IftheservercontinuestoresetduringPOST,seethe“POST”and

“Diagnosticprograms”sectionsintheProblemDeterminationandService Guide.

2. Iftheresetoccursaftertheoperatingsystemstarts,disableanyautomatic serverrestart(ASR)utilities,suchastheIBMAutomaticServerRestartIPMI ApplicationforWindows,orASRdevicesthatmaybeinstalled.

Note: ASRutilitiesoperateasoperating-systemutilitiesandarerelatedtothe IPMIdevicedriver.Iftheresetcontinuestooccuraftertheoperatingsystem starts,theoperatingsystemmighthaveaproblem;see“Softwareproblems”on page68.

3. Ifneitherconditionapplies,checkthesystem-errorlogorBMClog(see“Error Logs”intheProblemDeterminationandServiceGuide).

Iftheproblemremains,callforservice.

USB keyboard, mouse, or pointing-device problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

Allorsomekeysonthe

keyboarddonotwork. 1. RuntheConfiguration/SetupUtilityprogramandenablekeyboardlessoperation topreventthePOSTerrormessage301frombeingdisplayedduringstartup.

2. Makesurethat:

v Thekeyboardcableissecurelyconnected.

v Theserverandthemonitorareturnedon.

3. Reseatthekeyboardcable.

4. IfyouareusinganexternalUSBhub,disconnectthekeyboardfromthehub andconnectitdirectlytotheserver.

5. Replacethefollowingcomponentsoneatatime,intheordershown,restarting theservereachtime:

a. Keyboard

b. (Trainedservicetechnicianonly)Systemboard TheUSBmouseorUSB

pointingdevicedoesnotwork. 1. Makesurethat:

v Themouseorpointing-deviceUSBcableissecurelyconnectedtothe server,andthekeyboardandthedevicedriversareinstalledcorrectly.

v Theserverandthemonitorareturnedon.

v KeyboardlessoperationhasbeenenabledintheConfiguration/SetupUtility program.

2. Reseatthemouseorpointing-devicecable.

3. IfyouareusinganexternalUSBhub,disconnectthemouseorpointingdevice fromthehubandconnectitdirectlytotheserver.

4. Replacethefollowingcomponentsoneatatime,intheordershown,restarting theservereachtime:

a. Mouseorpointingdevice

b. (Trainedservicetechnicianonly)Systemboard

Memory problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

Theamountofsystemmemory thatisdisplayedislessthanthe amountofinstalledphysical memory.

1. Makesurethat:

v

NolightpathdiagnosticsLEDsarelitontheoperatorinformationpanel.

v Memorymirroringorsparingdoesnotaccountforthediscrepancy.

v TheDIMMsareseatedcorrectly.

v Youhaveinstalledthecorrecttypeofmemory.See“Installingamemory module”onpage19.

v Ifyouchangedthememory,youupdatedthememoryconfigurationinthe Configuration/SetupUtilityprogram.

v Allbanksofmemoryareenabled.Theservermighthaveautomatically disabledamemorybankwhenitdetectedaproblem,oramemorybank mighthavebeenmanuallydisabled.

2. CheckthePOSTerrorlogforerrormessage289:

v IfaDIMMwasdisabledbyasystem-managementinterrupt(SMI),replace theDIMM.

v IfaDIMMwasdisabledbytheuserorbyPOST,runtheConfiguration/Setup UtilityprogramandenabletheDIMM.

3. Runmemorydiagnostics(see“Runningthediagnosticprograms”inthe ProblemDeterminationandServiceGuide).

4. AddonepairofDIMMsatatime,makingsurethattheDIMMsineachpairare matching.InstalltheDIMMsinthesequencedescribedin“Installingamemory module”onpage19.

5. ReseattheDIMMs.See“Installingamemorymodule”onpage19.

6. Replacethefollowingcomponentsoneatatime,intheordershown,restarting theservereachtime:

a. DIMMs

b. (Trainedservicetechnicianonly)Systemboard MultiplerowsofDIMMsina

branchareidentifiedasfailing. 1. ReseattheDIMMs;then,restarttheserver.

2. Replacethelowest-numberedDIMMpairofthoseidentified;then,restartthe server.Repeatasnecessary.

3. (Trainedservicetechnicianonly)Replacethesystemboard.

Microprocessor problems

v FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblem issolved.

v SeethepartslistingintheProblemDeterminationandServiceGuideontheIBMSystemxDocumentation CDtodeterminewhichcomponentsarecustomerreplaceableunits(CRU)andwhichcomponentsarefield replaceableunits(FRU).

v Ifanactionstepisprecededby“(Trainedservicetechnicianonly),”thatstepmustbeperformedonlybya trainedservicetechnician.

Symptom Action

Theserveremitsacontinuous beepduringPOST,indicating thatthestartup(boot) microprocessorisnotworking correctly.

1. CorrectanyerrorsthatareindicatedbythelightpathdiagnosticsLEDs(see

“Lightpathdiagnostics”onpage68).

2. Makesurethattheserversupportsthemicroprocessor.

3. (Trainedservicetechnicianonly)Makesurethatthemicroprocessorisseated correctly.

4. (Trainedservicetechnicianonly)Replacethemicroprocessor.

Monitor problems

Some IBMmonitorshave theirownself-tests.If yoususpecta problemwithyour monitor, seethedocumentationthatcomeswiththemonitorforinstructionsfor testing andadjustingthemonitor.If youcannotdiagnosetheproblem,call for

Some IBMmonitorshave theirownself-tests.If yoususpecta problemwithyour monitor, seethedocumentationthatcomeswiththemonitorforinstructionsfor testing andadjustingthemonitor.If youcannotdiagnosetheproblem,call for