Pressing the View Opts button displays the View Options menu screen (Figure 4-23). This screen has three buttons for viewing different sets of options currently configured for your ARCvault loader. The displayed options are read-only and cannot be changed. No security password is required to access these screens.
Cleaning Displays the current cleaning status of the drive:
• OK—Normal operation
• Requested—Will require cleaning soon but can still operate
• Required—Cannot function until the drive is cleaned H/W Comp Shows if hardware compression is Enabled or Disabled.
Err Status Provides the current drive functional status—OK, Warning, or Critical.
Table 4-4: Drive Info Screen Data (Continued)
Option Description
Table 4-5: Setup Menu Options
Option Description
View Opts Button Allows all users to view the current configuration options in read-only mode.
Edit Opts Button Permits users with Administrator security level to view and change many of the unit’s options.
Passwords Button Manages security access to different OCP options by using numeric passwords.
Figure 4-23: View Options Screen
Library Button (View-Only)
The Library button provides read-only access to the ARCvault 12 primary settings and displays several screens of information in read-only format (Figure 4-24). Use the and arrows to shift between option screens.
Figure 4-24: View Library Options Screen
NOTE: To edit these options, refer to the Library button under Edit Opts (page 4-17).
Table 4-6 lists the items shown and provides a brief description:
Table 4-6: Viewable Library Options
Option Description
Reserved Slots The reserved slots can be used to store cleaning cartridges or to reduce the number of active slots to meet host software
requirements.
LCD Contrast Shows the contrast setting between 0 and 63 for the LCD display.
Bar Code Label
Exhibits the maximum number of bar code characters (1–12) reported to both the host and the Cartridge Map.
Bar Code Alignment
If there are more characters in the bar code than configured as the maximum number, then only the specified number of characters are reported taken from either the Left or Right end of the code based on this setting.
Bar Code Check Digit
Shows whether or not the verification of a check digit character in the bar code label is enabled.
Figure 4-25: View Network Options Screen
NOTE: To edit these options, refer to the Network button under Edit Opts (page 4-18).
Use the and arrows to shift between screens. Table 4-7 lists the items shown and provides a brief description. Refer to “Network Button (Editable)” on page 4-18 for a list of items that can be configured from the OCP.
SCSI/FC Button (View-Only)
The SCSI/FC button provides read-only access to the SCSI settings. Pressing this button displays several read-only screens showing the different options currently used in the loader (Figure 4-26).
Table 4-7: Viewable Network Options
Option Description
IP Address Assignment
Displays the method used for setting the IP address of the loader’s RMU protected website.
IP Addr Shows the static IP address used to access RMU.
NOTE: Only visible if the IP address assignment is set to Static.
Static IP Mask Displays the static Subnet Mask address used to access RMU.
NOTE: Only visible if the IP address assignment is set to Static.
Static IP Gateway Specifies the static Gateway IP address used to access RMU.
NOTE: Only visible if the IP address assignment is set to Static.
DNS Server Lists the static DNS server address used.
NOTE: Only visible if the IP address assignment is set to Static.
Web Lvl 1
& FTP Login
Shows asterisks for password used for access to RMU Level 1 security (User) and FTP activities.
Web Lvl 2 Login
Shows asterisks for password used to access RMU Level 2 security (Administrator).
Disable Web Lvl 2 Access
Denotes if Level 2 security access (Administrator) using the RMU is allowed.
Figure 4-26: View SCSI Options Screen
NOTE: To edit the Drv n Bus ID option, refer to the SCSI/FC button under Edit Opts (page 4-20). All other options are only editable using the RMU.
Use the and arrows to shift between screens. Table 4-8 lists the items shown and provides a brief description.
Table 4-8: Viewable SCSI/FC Options Definition Option and Default Description
Drv n Bus ID
(if SCSI drives installed)
Lets you set the SCSI address of the drive.
Init Elem Status
Specifies the loader’s response to the SCSI Initialize Element Status command.
Dev Capbl’s Page Len
Shows if the unit uses Short or Long lengths of the Mode Sense/
Select Device Capabilities Page.
Xport Elem Base Addr
Exhibits the base address for the Transport Element (robotics) of the loader.
Storage Elem Base Addr
Shows the base address for the Storage Elements (magazine slots) of the loader.
Xfer Elem Base Addr
Specifies the base address for the Transfer Elements (tape drives) of the loader.
In/Out Elem Base Addr
Exhibits the base address for the Import/Export Element of the loader.
Post Recvr’d Errors
Specifies the setting for a TapeAlert informational exception.
TapeAlert Mode
Details the conditions for logging and reporting a TapeAlert data options.
Abort Move Status
Displays the loader’s response if it receives a SCSI Reset or Abort command while a Move Medium command is in progress.
Report Elem Type
Shows the method used to report the type of loader elements installed (such as LTO drives) using the SCSI Read Element Status