• No results found

a tem.

A TEM Study of Cobalt Base Alloy Prototypes Fabricated by EBM

A TEM Study of Cobalt Base Alloy Prototypes Fabricated by EBM

... a TEM bright-field im- age of intrinsic stacking faults in the (112) orientation for the annealed Co-base alloy in Figure ...a TEM image of stacking faults intersecting at ~90˚ in a (100) grain orientation ...

9

A TEM-traceable physiologically functional gold nanoprobe that permeates non-endocytic cells

A TEM-traceable physiologically functional gold nanoprobe that permeates non-endocytic cells

... Notes: sperm were incubated with 20 µg/mL CPP-MT-AuNP or BSA-coated AuNP (control) for 3 hours. Samples were fixed and processed for electron microscopy as described in section “Materials and methods”. left: TeM ...

12

Design of tem cell to test the electromagnetic sensor

Design of tem cell to test the electromagnetic sensor

... a TEM cell was built to test the sensor frequency response in an attempt to calibrate the sensor for PD ...The TEM cell can also be used to test the sensor response for specific pulses such as the step ...

6

Photons Are EM Energy Superpositioned on TEM Waves

Photons Are EM Energy Superpositioned on TEM Waves

... decay of high energy atomic nucleus, see Figure 3. In this case the dipole 6 in the electron or the atomic nu- cleus contains the energy package hν where h is Planck constant or quantum of action. The energy package hν ...

10

Design and fabrication of a novel wideband tem – cell for dielectric measurements

Design and fabrication of a novel wideband tem – cell for dielectric measurements

... waveguides which becomes very large, expensive and non-practice for the lower frequencies in the MHz range. A TEM parallel-plate cell can operate from very low- frequencies and for a wideband frequency-range with ...

34

TEM Sample Preparation for Microcompressed Nanocrystalline Ni

TEM Sample Preparation for Microcompressed Nanocrystalline Ni

... A focused ion beam (FIB) apparatus (Hitachi High- Technologies Corporation FB-2100) was used to fabricate the Ni plate for obtaining a microsized cylinder and a TEM sample from the deformed microcylinder. An FIB ...

5

AFM, ESEM, TEM, and CLSM in liposomal characterization: a comparative study

AFM, ESEM, TEM, and CLSM in liposomal characterization: a comparative study

... Briefly, a drop of a water-diluted suspension of the liposomes (about 0.05 mg/mL) was placed on a 200-mesh formvar copper grid (TABB Laboratories Equipment, Berks, UK), allowed to adsorb and the surplus was removed by ...

7

Development of TEM Holder Generating In Plane Magnetic Field Used for In Situ TEM Observation

Development of TEM Holder Generating In Plane Magnetic Field Used for In Situ TEM Observation

... A TEM holder with a pair of four-pole electromagnets was developed, which enabled us to apply an in-plane magnetic field along any direction. The maximum magnetic field available was ³15.9 kA/m (200 Oe). The design ...

7

Extended measurement setup for transient TEM waveguide characterization

Extended measurement setup for transient TEM waveguide characterization

... of TEM waveguides is performed in time domain (TD). There a TEM waveguide is supplied with the above mentioned ...the TEM waveguide is evaluated by a parameter comparison – the rise time and the ...

6

Transmission electron microscopy and spectroscopy of carbon based nanomaterials

Transmission electron microscopy and spectroscopy of carbon based nanomaterials

... of TEM-based charac- terisation techniques in the emerging field of carbon nanomaterials, graphene in partic- ...a TEM study of 2D materials is sample ...

138

Coexistence of SHV 4  and TEM 24 Producing Enterobacter aerogenes Strains before a Large Outbreak of TEM 24 Producing  Strains in a French Hospital

Coexistence of SHV 4 and TEM 24 Producing Enterobacter aerogenes Strains before a Large Outbreak of TEM 24 Producing Strains in a French Hospital

... a TEM-type or an SHV-type ...a TEM-24 ...the TEM-24-producing clone in France (8); a representative selection of ...of TEM-24 ESBL in French hospitals was recently confirmed ...

7

A device for simulating the thermoregulatory responses of the foot : estimation of footwear insulation and evaporative resistance

A device for simulating the thermoregulatory responses of the foot : estimation of footwear insulation and evaporative resistance

... Som e reference tests have been done to c h e c k th e system behavior and to com pare our m a n ik in w ith other m anikins. F or this reason we d id fo u r tests w ith bare foot, sock, rubber boot a n d w in ter boot. ...

11

Beta Lactam Antibiotic Resistance among Enterobacter spp  Isolated from Infection in Animals

Beta Lactam Antibiotic Resistance among Enterobacter spp Isolated from Infection in Animals

... From the six Enterobacter isolates stored, five tested positive for possible ESBL presence from the DDST. In confirmation of the DDST, the samples were further evaluated by testing for ESBL gene presence with PCR. The ...

9

Experimental Prediction of the Natural Evolution of Antibiotic Resistance

Experimental Prediction of the Natural Evolution of Antibiotic Resistance

... Rebuck, J. A., K. M. Olsen, P. D. Fey, K. L. Bergman and M. E. Rupp, LITERATURE CITED 2000 In vitro activities of parenteral beta-lactam antimicrobials against TEM-10-, TEM-26- and SHV-5-derived ...

6

Synthesis and characterisation of reduced graphene oxide/bismuth composite for electrodes in electrochemical energy storage devices

Synthesis and characterisation of reduced graphene oxide/bismuth composite for electrodes in electrochemical energy storage devices

... Transmission Electron Microscopy (TEM) images of rGO and rGO/Bi are shown in Figure 4 a) and b) respectively. Agglomeration is observed to occur in isolated regions of the sample, forming bismuth aggregates with ...

18

Improving the implementation of tailored expectant management in subfertile couples: protocol for a cluster randomized trial

Improving the implementation of tailored expectant management in subfertile couples: protocol for a cluster randomized trial

... Background: Prognostic models in reproductive medicine can help to identify subfertile couples who would benefit from fertility treatment. Expectant management in couples with a good chance of natural conception, i.e., ...

7

spat and tem

spat and tem

... SPATIAL AND TEMPORAL RAINFALL GAUGE DATA ANALYSIS AND COMPARISON WITH TRMM... SPATIAL AND TEMPORAL RAINFALL GAUGE DATA ANALYSIS AND COMPARISON WITH TRMM..[r] ...

95

In situ TEM study of Nd rich phase in NdFeB magnet

In situ TEM study of Nd rich phase in NdFeB magnet

... TEM dark field did not favour two phases coexisting, and a BCC superlattice with twice the lattice parameter of the fundamental FCC lattice was suggested [7]. The fourth structure of Nd-rich phases is a HCP ...

6

Synthesis and Characterization of Novel Nanoparticles for Use  as Photocatalytic Probes and Radiotracers

Synthesis and Characterization of Novel Nanoparticles for Use as Photocatalytic Probes and Radiotracers

... An aliquot of tetrachloroauric acid solution was placed in a quartz test tube and to it was added 100 µl of preformed magnetite suspended in methanol (~1 mg of magnetite). It was shaken thoroughly so that the magnetite ...

152

TEM Assessments of the Restructuring Effects of an Emollient Cream on the stratum corneum

TEM Assessments of the Restructuring Effects of an Emollient Cream on the stratum corneum

... These TEM assessments allowed identifying the structural changes occurring in the stratum corneum of skin explants exposed to SLS and/or treated with an ...

8

Show all 10000 documents...

Related subjects