• No results found

Amplatzer Septal Occluder Device

Outcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder

Outcome of Transcatheter Closure of Oval Shaped Atrial Septal Defect with Amplatzer Septal Occluder

... atrial septal de- fects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the ...atrial septal de- fect. We defined an oval shaped atrial ...

6

Endocarditis After Closure of Ventricular Septal Defect by Transcatheter Device

Endocarditis After Closure of Ventricular Septal Defect by Transcatheter Device

... platzer septal occluder was designed for the percutane- ous transcatheter occlusion of septal ...double-disk device with a connecting waist made from Nitinol wire ...the device. The ...

5

Long Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal Occluder

Long Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal Occluder

... Chest pain was a common complaint through- out the follow-up period. Although the complaint was common, a cardiac etiology was rare. Interest- ingly, no patient complained of chest pain during the first month after ASO ...

6

Transcatheter and intraoperative device closure and surgical repair for atrial septal defect

Transcatheter and intraoperative device closure and surgical repair for atrial septal defect

... transcatheter Amplatzer device closure for ASD at a median age of 12 years ...the device group. Thus, they prefer the de- ployment of an Amplatzer septal occluder to surgical re- ...

6

Percutaneous Device Closure of Atrial Septal Defect in a Premature Infant With Rapid Improvement in Pulmonary Status

Percutaneous Device Closure of Atrial Septal Defect in a Premature Infant With Rapid Improvement in Pulmonary Status

... 6-mm Amplatzer septal occluder (AGA Medical, Golden Valley, MN) was chosen and deployed across the ...the device, significant caudal displacement of the atrial septum was ...the device ...

5

Septal Closure Device

Septal Closure Device

... atrial septal defects are diagnosed in the United States every year ...atrial septal defect occurs when the foramen ovale fails to close after ...the Amplatzer septal occluder (ASO), ...

25

Original Article Mismatch in size of occluding devices for atrial septal defect (ASD) impairs endothelialization of the occluder surface in a canine ASD model

Original Article Mismatch in size of occluding devices for atrial septal defect (ASD) impairs endothelialization of the occluder surface in a canine ASD model

... of Amplatzer occluder in 1997 solved these problems and Amplatzer septal occluder became the most widely used device for percutaneous ASD closure now ...mostly Amplatzer ...

9

Transcatheter closure of ventricular septal defect from retrograde transarterial approach: immediate and long-term outcome

Transcatheter closure of ventricular septal defect from retrograde transarterial approach: immediate and long-term outcome

... As the procedure was performed by using retrograde approach, we used devices which can be delivered through small size delivery systems. Amplatzer duct occluder II (ADO II, Abbott vascular solution, USA) ...

7

Cardiac Perforation 6 Weeks After Percutaneous Atrial Septal Defect Repair Using an Amplatzer Septal Occluder

Cardiac Perforation 6 Weeks After Percutaneous Atrial Septal Defect Repair Using an Amplatzer Septal Occluder

... The child was taken urgently to the operating room, where a median sternotomy was performed, the hemo- pericardium was evacuated, and cardiopulmonary by- pass was instituted. A perforation in the superior-poste- rior ...

6

Surgical Retrieval of Atrial Septal Occluder Device after Late Embolization in Right Ventricle

Surgical Retrieval of Atrial Septal Occluder Device after Late Embolization in Right Ventricle

... Atrial septal defects (ASDs) are one of the most common congenital heart de- fects, with a prevalence estimated to affect 100 of 100,000 live births [1] ...this septal defect are available, provided that ...

6

Randomized clinical trial comparing percutaneous closure of patent foramen ovale (PFO) using the Amplatzer PFO Occluder with medical treatment in patients with cryptogenic embolism (PC Trial): rationale and design

Randomized clinical trial comparing percutaneous closure of patent foramen ovale (PFO) using the Amplatzer PFO Occluder with medical treatment in patients with cryptogenic embolism (PC Trial): rationale and design

... guide device implantation by fluoroscopy only or use simultaneous transesophegeal echocardiography (TEE) or intracardiac echocardiography (ICE) was left to the implanting ...atrial septal defects) balloon ...

8

A retrospective study: elevation of cardiac troponin T after transcatheter closure of the interatrial septum is related to device size and procedural duration

A retrospective study: elevation of cardiac troponin T after transcatheter closure of the interatrial septum is related to device size and procedural duration

... the device position and stability, and to detect any residual ...An Amplatzer Septal Occluder was used in 46 cases, and an Occlutech Figulla septal occluder in 2 ...

5

Successful device closure of a post-infarction ventricular septal defect

Successful device closure of a post-infarction ventricular septal defect

... remnant septal defect percutaneously using the VSD ...VSD Occluder had a maximum size of 16 mm (AMPLATZER™ Muscular VSD Occluder device, St Jude Medical, St Paul, MN, ...The ...

5

Read PDF

Read PDF

... both device and medical groups were much lower than expected which lowered the power of the trial ...the Amplatzer device appeared to be superior to that of the STARFlex device tested in ...

8

A meta-analysis of perventricular device closure of perimembranous ventricular septal defect

A meta-analysis of perventricular device closure of perimembranous ventricular septal defect

... for occluder dislodgement and 3 for ...pacemaker. Occluder dislodgement may be a procedure-related com- plication caused by a lack of experience with ...

10

Perventricular device closure of a doubly committed juxtaarterial ventricular septal defect through a left parasternal approach: midterm follow-up results

Perventricular device closure of a doubly committed juxtaarterial ventricular septal defect through a left parasternal approach: midterm follow-up results

... The device was inspected repeatedly by a push-pull maneuver and re- leased only when its proper position was obtained and interference with the aortic and pulmonary valve had been ...The device stay suture ...

8

Minimally invasive perventricular device closure of ventricular septal defect in infants under transthoracic echocardiograhic guidance: feasibility and comparison with transesophageal echocardiography

Minimally invasive perventricular device closure of ventricular septal defect in infants under transthoracic echocardiograhic guidance: feasibility and comparison with transesophageal echocardiography

... Some technical considerations of perventricular VSD device closure should also be addressed. First, passing the guide-wire and the delivery sheath across the defect is a crucial step for successful closure. The ...

6

Current perspectives in percutaneous atrial septal defect closure devices

Current perspectives in percutaneous atrial septal defect closure devices

... atrial septal defect (ASD) closure has become the treatment of choice in most clinical presentations of ...improved device structure and ...closure device usage in the last four decades incorporates ...

7

Hemolysis and its outcome following percutaneous closure of cardiac defects among children and adolescents: a prospective study

Hemolysis and its outcome following percutaneous closure of cardiac defects among children and adolescents: a prospective study

... ASD Amplatzer devices for VSD ...from Amplatzer mesh can lead to erythrocyte fragmentation and ...ASD Amplatzer had occurred; hence they had to remove the device surgically, and the VSD was ...

6

Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update

Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update

... WATCHMAN device through a 12-Fr transseptal delivery ...WATCHMAN device — consisting of a self-expanding nitinol frame covered with a porous filtering PET ...the device is secured by fixation barbs ...

14

Show all 8126 documents...