Customised Fixation Plate Design Using Fracture

Assessment of Carbon Fibre Composite Fracture Fixation Plate Using Finite Element Analysis

Assessment of Carbon Fibre Composite Fracture Fixation Plate Using Finite Element Analysis

... The output of this program in addition to nodal displacements gave the stress state at any location of the fracture plate. In areas with high stress gradients a fine mesh was required for an accurate model ...

11

Surgical treatment of avulsion fracture around joints of extremities using hook plate fixation

Surgical treatment of avulsion fracture around joints of extremities using hook plate fixation

... arthroscopic-assisted fixation was a simple and feasible alternative for treating PCL avulsion ...internal fixation methods for avulsion fracture include screws, steel wires, K-wire tension band, ...

7

Finite element stress analysis of a hybrid fracture fixation plate

Finite element stress analysis of a hybrid fracture fixation plate

... reinforced plate system that combines the torsional and bending rigidity of a metal plate with the axial compliance of a polymer insert has been ...hybrid design. A model with a standard metal ...

12

Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture

Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture

... done using Constant shoulder score ...evaluate fracture union and any complication like fracture displacement, loss of reduction or varus- valgus angulation was also ...screw, plate breakage ...

5

Design and Fracture Analysis of Thin Plate

Design and Fracture Analysis of Thin Plate

... a plate which is having crack height, width of 10&20mm respectively at one end of plate , and to determine the stress intensity factor(k) for ...the fracture analysis we are using FINITE ...

11

Comparison between new design interlocking nail with plate fixation and intramedullary pin with external skeletal fixation in long bone fracture in the dogs

Comparison between new design interlocking nail with plate fixation and intramedullary pin with external skeletal fixation in long bone fracture in the dogs

... New design interlocking nail and plate fixation was used in comminuted femur fracture in an old dog that the results showed primary bone healing and she had been quickly weight baring in ...

5

Plate Fixation Technique for Reducing Osteoarticular Allograft Fracture: A Preliminary Report

Plate Fixation Technique for Reducing Osteoarticular Allograft Fracture: A Preliminary Report

... of plate and screw fixation in osteochondral allograft following removal of aggressive bone ...reconstructed using standard technique and 23 patients were fixed using only one dynamic ...

9

Intramedullary nail fixation versus locking plate fixation for adults with a fracture of the distal tibia : the UK FixDT RCT

Intramedullary nail fixation versus locking plate fixation for adults with a fracture of the distal tibia : the UK FixDT RCT

... External fixation leads to the least soft-tissue stripping of any surgical intervention; the external fixation pins/wires being inserted through tiny wounds in the ...external fixation in their ...

175

Conservative treatment, plate fixation, or prosthesis for proximal humeral fracture  A prospective randomized study

Conservative treatment, plate fixation, or prosthesis for proximal humeral fracture A prospective randomized study

... two-part fracture will be randomized to either conservative or plate-fixation ...tive, plate fixation, or prosthesis groups. Both fracture types will be randomized using a ...

7

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

Failure of volar locking plate fixation of an extraarticular distal radius fracture: A case report

... radius fracture, underwent open reduction and internal fixation of the fracture using a volar locking ...of fixation with breakage of the four distal locking ...a fracture- ...

6

Fixation of proximal humerus fractures using philos plate

Fixation of proximal humerus fractures using philos plate

... anaesthesia using the anterior deltopectoral ...PHILOS plate was ideally placed 8-10 mm distal to the superior tip of the greater tuberosity just lateral to bicipital groove from the lateral view, the ...

6

Internal Fixation of Mallet Fractures Using a Hook Plate

Internal Fixation of Mallet Fractures Using a Hook Plate

... hook plate for bony mallet ...or fracture frag- ment displaced more than 3 mm. We used hook plate which prebend the ...evaluated using Crawford ...

5

ORIGINAL PAPER THE RESULTS OF VOLAR LOCKING PLATE FIXATION FOR THE FRAGILITY FRACTURE POPULATION WITH DISTAL RADIUS FRACTURE IN JAPANESE WOMEN

ORIGINAL PAPER THE RESULTS OF VOLAR LOCKING PLATE FIXATION FOR THE FRAGILITY FRACTURE POPULATION WITH DISTAL RADIUS FRACTURE IN JAPANESE WOMEN

... assessed using the Chi-square test for categorical ...analyzed using Student’s t-test or the Mann-Whitney U test, as ...circumvented using a classical method known as the ...

11

A Smart Implantable Bone Fixation Plate Providing Actuation and Load Monitoring for Orthopedic Fracture Healing

A Smart Implantable Bone Fixation Plate Providing Actuation and Load Monitoring for Orthopedic Fracture Healing

... The fixation plate was placed on the femur and clamped using a stainless-steel ...clamping plate was used to distribute the load from the clamp across the fixation plate to ...

135

Biomechanical evaluation of fracture construct for fracture fixation of the tibia

Biomechanical evaluation of fracture construct for fracture fixation of the tibia

... for fracture fixation, the LCP and DCP be used in this study as the ...cases using three different ...LCP plate with combination screws hole for fixation of tibial ...claw plate ...

33

Comparative Study of Fracture Metacarpals Treated by Orif by Minifragment Plate vs Closed Kirschner’s Wire Fixation

Comparative Study of Fracture Metacarpals Treated by Orif by Minifragment Plate vs Closed Kirschner’s Wire Fixation

... 3 Fracture healing in the hand is not an isolated goal rather the functional result is of paramount ...fractures using miniplates and screws as compared to the conservative treatment or K –wire ...

9

Outcome Analysis of Intra-Articular Scapula Fracture Fixation with Distal Radius Plate: A Multicenter Prospective Study

Outcome Analysis of Intra-Articular Scapula Fracture Fixation with Distal Radius Plate: A Multicenter Prospective Study

... capsule. Fracture was visualized and reduced under direct vision of both the intra-articular and extra-articular ...glenoid fracture with a ...intra-articular fracture was achieved using a 3.5 ...

8

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.

... wire fixation and locking plate fixation are inherent in the design of the implants, there are several different implant systems and several different options for the positioning of wires and ...

10

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius : randomised controlled trial

Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius : randomised controlled trial

... wire fixation and locking plate fixation are inherent in the design of the implants, there are several different implant systems and several different options for the positioning of wires and ...

11

Management of comminuted patellar fracture fixation using modified cerclage wiring

Management of comminuted patellar fracture fixation using modified cerclage wiring

... discussed. Plate and screw fixations are used for the treatment of patellar fracture, but biomechanical studies are mainly used for the treatment of transverse patellar fracture or inferior patellar ...

8

Show all 10000 documents...