• No results found

double-circuit transmission system

Protection of parallel transmission lines including inter-circuit faults using Naïve Bayes classifier

Protection of parallel transmission lines including inter-circuit faults using Naïve Bayes classifier

... power system network under consideration is shown in ...Hz double circuit transmission line of length 100 ...short circuit capacity of source is 1250 MVA and X/R ratio is ...in ...

9

Adaptive neuro-fuzzy inference system based evolving fault locator for double circuit transmission lines

Adaptive neuro-fuzzy inference system based evolving fault locator for double circuit transmission lines

... of circuit and spreading to other phases after some ...in double circuit transmission line until ...in double circuit transmission line is proposed by considering adaptive ...

8

Fault Classification in Double-Circuit Transmission Lines Based on the Hierarchical Temporal Memory

Fault Classification in Double-Circuit Transmission Lines Based on the Hierarchical Temporal Memory

... on transmission lines could be broadly classified into two, namely: two-terminal method and one-terminal ...addition, transmission line fault location approaches could also be categorized into impedance ...

7

Field Problems of Distance Relays with Combined Single/Double
Circuit Transmission Lines

Field Problems of Distance Relays with Combined Single/Double Circuit Transmission Lines

... the system of ...of transmission line models are available in the EMTP starting from simple lumped parameter one to the distributed parameters ...a transmission line by modeling the frequency ...

6

Application of non superconducting fault current limiter to improve transient stability

Application of non superconducting fault current limiter to improve transient stability

... In this paper transient stability improvement of power system with double circuit transmission line using NSFCL is presented. Proposed structure can enter an optimum value of resistor to the ...

5

Artificial Neural Network Based Fault Location Estimation of Double Circuit Transmission Line

Artificial Neural Network Based Fault Location Estimation of Double Circuit Transmission Line

... Abstract: An accurate fault location estimation algorithm based on application of artificial neural networks (ANN) for the protection of double circuit transmission lines is presented. The proposed ...

8

Double Circuit Transmission Line Protection using Line Trap & Artificial Neural Network MATLAB Approach

Double Circuit Transmission Line Protection using Line Trap & Artificial Neural Network MATLAB Approach

... enhance system stability, the relaying schemes supported traveling wave square measure planned [3, ...for transmission lines are planned within the past for fault detection and classification (phase ...

6

Simulation of Merged AC and DC System for Power Upgradation

Simulation of Merged AC and DC System for Power Upgradation

... existing double circuit EHVAC line into a simultaneous AC-DC transmission ...line.Double circuit line is compared with AC DC line Sending end power, receiving end power and transmission ...

5

Probabilistic Security Evaluation Software for Bulk Power System Considering Bus Arrangement

Probabilistic Security Evaluation Software for Bulk Power System Considering Bus Arrangement

... For double bus-bar or single bus-bar subsection, part feeders connect on one bus-bar and others connect on the other ...If circuit breaker and protection system operate naturally, bus-bar fault will ...

6

Fault Detection and Classification in Transmission Line by using Support Vector Machine Technique

Fault Detection and Classification in Transmission Line by using Support Vector Machine Technique

... HVDC system by using Support Vector Machine (SVM) in [1], faults on double circuit transmission line by using decision tree based method as in [3], on medium voltage DC shipboard by using ...

9

The stable way. Synchronous condenser solutions. siemens.com/energy/facts

The stable way. Synchronous condenser solutions. siemens.com/energy/facts

... the transmission system with a short-circuit power of more than 800 MVA in addition to reactive power ...the transmission system oper- ator ...the transmission network without ...

8

DJ-180 Service Manual DJ-1400

DJ-180 Service Manual DJ-1400

... Control Circuit The automatic power control(APC) circuit is used to obtain a stable transmis- sion ...This circuit detects the transmission power by D8 in the low- pass filter consisting of ...

46

Power quality improvement by using Interphase power controller

Power quality improvement by using Interphase power controller

... The controllable parameters are phase shift angles. The phase shifting device may be conventional or electronically switched static phase shifting Transformer (SPST).An IPC with electronically switched phase shifting ...

5

Bifurcation Analysis of a Resistor-Double Inductor and Double Diode circuit and a comparison with a Resistor-Inductor-Diode circuit in phase space and parametrical responses

Bifurcation Analysis of a Resistor-Double Inductor and Double Diode circuit and a comparison with a Resistor-Inductor-Diode circuit in phase space and parametrical responses

... same circuit in order to identify the subharmonic features of the outputs ...RL-diode circuit exhibits an ideal cycle with the Feigenbaum parameter, ...RL-diode circuit has been used, not only for ...

10

Li-Fi Based Audio TransmissionWith Home/Office Automation System

Li-Fi Based Audio TransmissionWith Home/Office Automation System

... Light Fidelity (Li-Fi ) is future technology which replaces the Wi-Fi. Because Li-Fi overcomes disadvantages of Wi-Fi like Data Transfer speed of Li-Fi is more than 1Gbps while in Wi-Fi it is about 150 Mbps. Li-Fi uses ...

8

Portable RLC Parameter Measurement Instrument Based on The FPGA

Portable RLC Parameter Measurement Instrument Based on The FPGA

... The system abandoned the traditional bridge method, resonance method, using the classic volt-ampere law, in accordance with the definition of a five- terminal impedance measurement circuit design; A DDS ...

8

Automation Deflashing System For Blow Moulded Product

Automation Deflashing System For Blow Moulded Product

... pneumatic system is used as a means of workplace mechanization and automation where a major part of manual and tedious work may be supplemented controls for quick and economic ...the system components are ...

24

Circuit design with Independent Double Gate Transistors

Circuit design with Independent Double Gate Transistors

... independent double gate transistors the number of transistors can be reduced from four to two, merging transistors in parallel and in series as shown in ...for double gate MOSFET, but with extremely high ...

6

Braking System with Drowsiness Detection & Inner Wiper Mechanism for Accident Prevention

Braking System with Drowsiness Detection & Inner Wiper Mechanism for Accident Prevention

... the system eye blink detector has been introduced to minimize such accident ...the system the driver may any time press the button to stop the system while by pressing start button the system ...

7

Echo cancellation in voice telephony over ATM networks

Echo cancellation in voice telephony over ATM networks

... structured circuit emulation 4], 18] for voice over ATM oers some im- provement over basic circuit emulation, as it allows AAL 1 ATM connections to be estab- lished for n X 64-kbps circuits as opposed to a ...

84

Show all 10000 documents...

Related subjects