• No results found

excitation control

Suitable Feedforward Artificial Neural Network Automatic Voltage Regulator for Excitation Control System

Suitable Feedforward Artificial Neural Network Automatic Voltage Regulator for Excitation Control System

... (PID) excitation controller of synchronous ...of excitation controller, but the proposed controller for excitation control system is relatively most ...

7

Governing Control and Excitation Control for Stability of Power System Based on ANFIS

Governing Control and Excitation Control for Stability of Power System Based on ANFIS

... generator control is one of the most widely applied in the power industry ...the excitation control. Most of excitation controls are based on SISO-PID control, MIMO linear ...

9

Co-Active Neuro-Fuzzy Inference System for Governing Control and Excitation Control of Power System Stability

Co-Active Neuro-Fuzzy Inference System for Governing Control and Excitation Control of Power System Stability

... The excitation and governing control of generator play an important role in improving the dynamic and transient stability of power ...the excitation control and governing ...generator ...

9

Stability Analysis of Time Delayed Generator Excitation Control System using Resultant Theory

Stability Analysis of Time Delayed Generator Excitation Control System using Resultant Theory

... Time Delays have become unavoidable in Power System due to the usage of measurement devices and communication links for transferring the control signals. This paper investigates the effect of time delays on the ...

6

Simulation and Development of Automatic Excitation Control for Synchronous Motor

Simulation and Development of Automatic Excitation Control for Synchronous Motor

... As shown in Fig.3 one switch is kept between the rectifier output and the field. Because DC supply is applied when the synchronous motor will reach 95% of the rated speed. Power factor is measured by using the power ...

5

Physical Processes in the Damping of Electromechanical Oscillations of the Synchronous Machine with Magnitude-Phase Excitation Controller

Physical Processes in the Damping of Electromechanical Oscillations of the Synchronous Machine with Magnitude-Phase Excitation Controller

... the excitation control with AVR and power system stabilizer (PSS) in which additionally implemented feedbacks by parameters of the synchronous machine electromechanical state (rotor speed, frequency, ...

8

The coordinated control of SVC and excitation of generators Using Adaptive Fuzzy Control

The coordinated control of SVC and excitation of generators Using Adaptive Fuzzy Control

... and control of differential and algebraic systems, the Indirect Adaptive fuzzy excitation control is presented in this paper for SVC (static var compensator) and generator excitation ...

11

Download
			
			
				Download PDF

Download Download PDF

... generators, excitation and steam flow control are expected to run concurrently for best ...results. Excitation control is expected to maintain terminal voltage within some specified limits and ...

15

“Stability Criterion of a Processing Plant using PID Controller”

“Stability Criterion of a Processing Plant using PID Controller”

... and excitation control system and it's associated with other measuring devices, communication links used for data ...having excitation loses and their ...

5

Application of SVC on Large Synchronous Motors Based on LOC Design (RESEARCH NOTE)

Application of SVC on Large Synchronous Motors Based on LOC Design (RESEARCH NOTE)

... optimization control (LOC), the measurable feedback signals are applied to the control system loops of SVC and the excitation control loop of the first synchronous ...

12

Performance Investigation of Various Flux-Switching Machines for Hybrid Electric Vehicles: A Review

Performance Investigation of Various Flux-Switching Machines for Hybrid Electric Vehicles: A Review

... all excitation sources located in the stator allowing a simple robust ...superior control capability, smooth flux and torque pulsation, as well as producing much higher torque density and efficiency, which ...

11

Fuzzy Logic based Power Factor Control of Synchronous Machine

Fuzzy Logic based Power Factor Control of Synchronous Machine

... In this paper, a fuzzy logic technique is used to control the power factor (PF) that compensate the reactive power of the load by controlling the excitation system of synchronous machine. This fuzzy logic ...

10

Modal Analysis of a Non-rotating Inflated Tire using Experimental and Numerical Methods

Modal Analysis of a Non-rotating Inflated Tire using Experimental and Numerical Methods

... The rim is expected to behave almost as a rigid body in this frequency range. Therefore, the responses of the rim are measured only at eight points. As shown in Figure 8 wheel is excited at points 1 on the tire in radial ...

7

Study of Combined Braking System Using Eddy Current

Study of Combined Braking System Using Eddy Current

... to control the excitation flux generated by permanent ...its excitation and power generation, record of experimental validation, investigation and simulation of the integration of the brake in ...

5

Energy saving optimal design and control of electromagnetic brake on passenger car

Energy saving optimal design and control of electromagnetic brake on passenger car

... passenger car was put forward by Sohel Anwar. The exper- imental data of braking torque and rotational speed was fit- ted to a formula (Anwar and Stevenson, 2006). The applica- tion of electromagnetic brake on the ...

14

A Short Review on the Active Control Approaches in Earthquake Engineering at the Last 10 Years (2008-2018)

A Short Review on the Active Control Approaches in Earthquake Engineering at the Last 10 Years (2008-2018)

... active control and semi active control approaches presented during the last ten ...active control approaches was not found in the ...active control approaches that have been presented in the ...

8

Using the Prony Analysis for Assessing Servo Drive Control

Using the Prony Analysis for Assessing Servo Drive Control

... In an initial approximation, the second order lag model fits to the closed velocity control loop. A damping of approximately 0.7 is aspired in most cases [3]. Especially a less damped behavior, which leads to a ...

6

Simulink Modelling of Current Control of Induction Generator by Using Hybrid Active Filter in Wind Energy System

Simulink Modelling of Current Control of Induction Generator by Using Hybrid Active Filter in Wind Energy System

... When SEIG supplies a non-linear load, the load draws a fundamental component of current and harmonic current from the generation systems, which are to be properly controlled. The universal bridge are working the AC to DC ...

8

Predicting the humidity control capacity of material based on a linear excitation-response relationship

Predicting the humidity control capacity of material based on a linear excitation-response relationship

... We adopted, as an excitation, a temperature jump and observed a resulting humidity response. Figure 1 shows typical variation of both relative humidity and absolute hu- midity in a steel box lined with material in ...

5

The Excitation of Nematocysts

The Excitation of Nematocysts

... If the response of the cnidae in such solutions is examined by touching the tentacle with a glass ball, it is found that in those cases where the dilute taurocholate is effective in prod[r] ...

17

Show all 10000 documents...

Related subjects