• No results found

field emission current density

Monte Carlo Computer Simulation of Nonuniform Field Emission Current Density for a Carbon Fiber

Monte Carlo Computer Simulation of Nonuniform Field Emission Current Density for a Carbon Fiber

... of field gain over the emitter surface is confirmed by the results of direct measurement with the use of a scanning anode tunnel emission microscope ...of field emission current ...

7

2D Porous ZnO Nanosheets: One Pot Synthesis with Low Turn-on Field

2D Porous ZnO Nanosheets: One Pot Synthesis with Low Turn-on Field

... The field emission current density-applied field (J-E) and current-time (I-t) measurements were carried out in all metal field emission microscope by using ‘close ...

8

A High Luminescence Fringelike Field Emission from Screen Printed Carbon Nanotube and Zinc Oxide Composite Film

A High Luminescence Fringelike Field Emission from Screen Printed Carbon Nanotube and Zinc Oxide Composite Film

... the field emission current densities of pure CNT and CNT-ZnO films as a function of applied ...tric field when the emission current density reaches 10 µA/cm 2 ) of the ...

5

Synthesis and field emission properties of different ZnO nanostructure arrays

Synthesis and field emission properties of different ZnO nanostructure arrays

... ture field emission current density versus the applied field (J-E) curves and the corresponding F-N plots (the inset of Figure 7) at different reaction time, respec- ...turn-on ...

11

High Current Emission from Patterned Aligned Carbon Nanotubes Fabricated by Plasma Enhanced Chemical Vapor Deposition

High Current Emission from Patterned Aligned Carbon Nanotubes Fabricated by Plasma Enhanced Chemical Vapor Deposition

... The current density was rela- tively stable both in the increased and decreased voltage ...the field emission testing, desorption and adsorption of the gas molecules will change the work ...

6

Cavanaugh_unc_0153D_15871.pdf

Cavanaugh_unc_0153D_15871.pdf

... For field emission a large negative potential is typically required to generate the requisite electric ...Many field emitters are designed to be operated at high vacuum (< 10 -6 Torr), and can ...

232

Field emission from non uniform carbon nanotube arrays

Field emission from non uniform carbon nanotube arrays

... average current more than varying three parameters in these ...the emission of a perfect ...total current [6]. Then, by increasing the external electric field, these few CNTs will become ...

6

Gold nanoarray deposited using alternating current for emission rate manipulating nanoantenna

Gold nanoarray deposited using alternating current for emission rate manipulating nanoantenna

... experimental result. There are several LSPR peaks ap- pearing at the nonuniform nanoarray extinction spectra, which are caused by the LSPRs of Au nanowires with different length. For the normal AC-grown nanoarrays, the ...

8

Flexible Field Emitter for X ray Generation by Implanting CNTs into Nickel Foil

Flexible Field Emitter for X ray Generation by Implanting CNTs into Nickel Foil

... in field emission properties under severe bending ...of emission current with the applied voltage and the corre- sponding F-N characteristics of the Ni foil emitter with respect to the bending ...

10

Flexible Field Emitter for X ray Generation by Implanting CNTs into Nickel Foil

Flexible Field Emitter for X ray Generation by Implanting CNTs into Nickel Foil

... This paper reports on a flexible Ni micro wire with CNTs embedded into its surface. By using micromachining technology, for the first time, we could implant nanoscale materials into micro-scale metal substrate at room ...

7

Nanoscale Field Emission Devices

Nanoscale Field Emission Devices

... high current densities this momentum transfer is enough to push metal ions along the length of the wire creating voids where the metal ion previously was and hillocks where the metal ions motion is ...concentrates ...

129

Micro Flowers of SrS Bi 2S3 Nanocomposite and Its Field Emission Properties

Micro Flowers of SrS Bi 2S3 Nanocomposite and Its Field Emission Properties

... applied field increases gradually, the emission current density is observed to increase exponentially and a maximum emission current density of ...applied field of ...

12

Comparison Analysis Of N-Channel And P-Channel SOI / Bulk Finfets

Comparison Analysis Of N-Channel And P-Channel SOI / Bulk Finfets

... memory density must continue to track the scaling trends of logic In the past few decades semiconductor industry is emerging with development of novel devices since Conventional Metal Oxide Semiconductor ...

5

Estimates of the field aligned current density in current carrying filaments using auroral zone ground based observations

Estimates of the field aligned current density in current carrying filaments using auroral zone ground based observations

... the field of view of both IRIS and ASC, provided there is no delay between auroral and absorption events (or at least the delay is not more than a few tens of ...the current filament co-locates with the ...

8

Field emission and stability

Field emission and stability

... fabricated field emitters showed that the extension of a metal-coated silicon tip with a carbon nanotube enhances its field emission ...the field enhancement ...the field ...

45

Diabolo Optical Antenna for Enhancing and Confining Electric Field Resonance

Diabolo Optical Antenna for Enhancing and Confining Electric Field Resonance

... electric field resonance of the diabolo optical antenna is investigated, considering impact of changing the antenna length and the antenna waist ...charge density is maximum at the extremities cause the ...

5

Electric field and current density performance analysis of Sf6,C4f8 and Co2 gases as an insulation

Electric field and current density performance analysis of Sf6,C4f8 and Co2 gases as an insulation

... electric field, current density and effect of electric field and current density when insulator has been ...electric field and current density produced on ...

13

Magnetic Field and Current Are Zero Inside Ideal Conductors

Magnetic Field and Current Are Zero Inside Ideal Conductors

... According to Thomson’s theorem, the electric charge on a set of conductors distributes itself on the conductor surfaces thereby minimizing the electrostatic energy. W. Thomson did not present a formal mathematical proof ...

26

Finite size suppression of the weak field magnetoresistance of lightly phosphorous-doped silicon

Finite size suppression of the weak field magnetoresistance of lightly phosphorous-doped silicon

... In the transverse orientation [Fig. 2(a) & (d)] there was little difference in the MR of the various thickness samples as there is no confinement in the directions orthogonal to the applied field. These data ...

15

Fields and flares : understanding the complex magnetic topologies of solar active regions

Fields and flares : understanding the complex magnetic topologies of solar active regions

... the field near the NL to become more vertical before the flare, as per the results found, and might explain the pre-flare energy build-up ...The field would then relax and become more horizontal after the ...

255

Show all 10000 documents...