• No results found

Glass electrode

FTO Coated Glass Electrode Functionalization with Transition Metal Cations Receptors via Electrostatic Self-Assembly

FTO Coated Glass Electrode Functionalization with Transition Metal Cations Receptors via Electrostatic Self-Assembly

... coated glass electrode surface with ionic assemblies in electrochemical study of these ...coated glass electrode functionalization, depending on the compounds used, on its response was studied ...

14

Computer simulation of precipitation titration for some cations
using pH glass electrode

Computer simulation of precipitation titration for some cations using pH glass electrode

... The analytical methods of qualitative and quantitative determination of ions in solutions are very flexible to automation. In this research by using a computer simulation a potentiometric titration of bromide and ...

9

THE DETERMINATION OF SODIUM IN BODY FLUIDS BY THE GLASS ELECTRODE

THE DETERMINATION OF SODIUM IN BODY FLUIDS BY THE GLASS ELECTRODE

... COMPARISON OF SODIUM ACTIVITIES NAS11-18 ELECTRODE WITH SIMULTANEOUSLY OBTAINED CONCENTRATION FLAME PHOTOMETER VALUES IN 104 URINES Deviation of activity measurements from the 1:1 slope [r] ...

13

Simultaneous Determination of Hydroquinone and Catechol using Carbon Glass Electrode Modified with Graphene Quantum Dots

Simultaneous Determination of Hydroquinone and Catechol using Carbon Glass Electrode Modified with Graphene Quantum Dots

... battery electrode materials and efficient catalysts ...the electrode surface to improve the electrode performance [26- ...modified electrode to determine dopamine with high sensitivity ...an ...

13

Sensitive Electrochemical Determination of Pantoprazole Sodium in Pure Form Pharmaceutical Formulations and Biological Fluid at Glassy Carbon Electrode Using Differential Pulls and Square wave Techniques

Sensitive Electrochemical Determination of Pantoprazole Sodium in Pure Form Pharmaceutical Formulations and Biological Fluid at Glassy Carbon Electrode Using Differential Pulls and Square wave Techniques

... carbon electrode as working electrode, a silver/silver chloride/saturated KCl as the reference electrode and a platinum wire as an auxiliary ...a glass electrode was used for the ...

12

Development of Non-Enzymatic Glucose Biosensors Based on Electrochemically Prepared Polypyrrole- Chitosan-Titanium Dioxide Nanocomposite Films Ali M.A. Abdul Amir AL-Mokaram 1,2, *, Rosiyah Yahya 1, Mahnaz M. Abdi 3,4 and Habibun Nabi Muhammad Ekramul Mah

Development of Non-Enzymatic Glucose Biosensors Based on Electrochemically Prepared Polypyrrole- Chitosan-Titanium Dioxide Nanocomposite Films Ali M.A. Abdul Amir AL-Mokaram 1,2, *, Rosiyah Yahya 1, Mahnaz M. Abdi 3,4 and Habibun Nabi Muhammad Ekramul Mahmud 1,

... Field emission scanning electron microscope (FESEM, Hitachi Brand, Model SU 8220) and high- resolution transmission electron microscope (HRTEM) (Tecnai model G2-F20)-Twin manufacture (FEI, USA) were used for the ...

10

Optimisation of embryonic and larval ECG measurement in zebrafish for quantifying the effect of QT prolonging drugs

Optimisation of embryonic and larval ECG measurement in zebrafish for quantifying the effect of QT prolonging drugs

... a glass electrode based setup, as described previously [20], we used 3 dpf larvae as the heart is fully developed at this stage and because they are easier to manipulate in terms of positioning within wells ...

10

Development of Microcontroller Based System for the Diagnosis of pH Electrode

Development of Microcontroller Based System for the Diagnosis of pH Electrode

... the glass electrode whose potential dependent on activity of H + ...ions. Glass electrode technology hasnot changed much in the past ...decade, glass electrode manufacturing ...

7

Recommendations for the electrometric determination of the pH of atmospheric wet deposition (acid rain)

Recommendations for the electrometric determination of the pH of atmospheric wet deposition (acid rain)

... Although usually not a serious problem with acid rain samples, organic materials dispersed in water may foul the glass electrode surface, particularly when analyzing low ionic strength s[r] ...

10

Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

Spectrophotometric high-precision seawater pH determination for use in underway measuring systems

... pH electrode from 16 to 20 July which can be explained with changes in the structure of the glass membrane due to aging and foul- ...a glass electrode with an indicator based optical system ...

11

FePt Thin Films Electrodeposited from Non-Aqueous Liquids

FePt Thin Films Electrodeposited from Non-Aqueous Liquids

... It illustrated that, deposition potential was increased with Fe(II) concentration,and the Fe (II)/Pt (IV) ions were deposited at the same time when the deposition potential and concentration were suitable. Otherwise, ...

13

STANDARDIZATION OF CARICA PAPAYA LEAF EXTRACT

STANDARDIZATION OF CARICA PAPAYA LEAF EXTRACT

... Accurately weighed 10 gm powder drug was dissolved in accurately measured 100 ml of distilled water, filtered and the pH of filtrate was checked with a standard glass electrode.. TLC[5,6[r] ...

9

Self-powered transparent glass-based single electrode triboelectric motion tracking sensor array

Self-powered transparent glass-based single electrode triboelectric motion tracking sensor array

... using glass and PDMS as the charging ...lower glass part is shown in ...lime glass at 1100 rpm for 10 sec to obtain a PDMS thin film with a thickness of ~100 μm ( note this glass was merely ...

15

Cathodic Using of ZrB2 αSiC and TiB2 αSiC for PEM Electrolysis and Water Electrolysis at Low Temperature

Cathodic Using of ZrB2 αSiC and TiB2 αSiC for PEM Electrolysis and Water Electrolysis at Low Temperature

... overpotential. Always at the speed of 0 rpm, comparison of both electrodes has been made with the linear vol- tammetry performed on bare platinum as displayed on Figure 4. It shows up that the bare platinum remains the ...

11

Negative Lead-Acid Battery Electrodes Doped with Glass Fibres

Negative Lead-Acid Battery Electrodes Doped with Glass Fibres

... of glass fibres can be important [8] and also fluid transfer properties [9, ...positive electrode pores is smaller than 1 µm, or 6 µm in case of negative electrode ...

14

Corrosion Protection and Biological Activity Studies for Electrochemical Polymerized Poly (N-benzothiozolyl tetrahydrophthalamic acid) on Stainless Steel Alloy

Corrosion Protection and Biological Activity Studies for Electrochemical Polymerized Poly (N-benzothiozolyl tetrahydrophthalamic acid) on Stainless Steel Alloy

... The present work reports the electrochemical synthesis of poly (N-benzothiozolyl tetrahydrophthalamic acid) on stainless steel 316 (S.S) which acts as working electrode by using electrochemical polymerization ...

8

Calcium ion selective electrodes with covalently bound sensor groups

Calcium ion selective electrodes with covalently bound sensor groups

... largely reversible. There was some permanent discolouration of the membrane material though,indicating some irreversible damage , and the electrode had to be recharged after 3 to 4 weeks of inter­ mittent use. ...

295

Electrochemically Deposited Nanograin Ruthenium Oxide as a Pseudocapacitive Electrode

Electrochemically Deposited Nanograin Ruthenium Oxide as a Pseudocapacitive Electrode

... an electrode materials for supercapacitors, the most success has been achieved using ruthenium oxide due to its advantages of a wide potential window of highly reversible redox reactions [6], remarkably high ...

8

Growth of a Pure and Single Phase Iron Sulfide (Pyrite) Thin Film by Electrochemical Deposition for Photovoltaic Applications

Growth of a Pure and Single Phase Iron Sulfide (Pyrite) Thin Film by Electrochemical Deposition for Photovoltaic Applications

... these techniques, electrochemical deposition offers several advantages such as; the ability to control film thickness, composition, morphology, etc. by mainly controlling electrical parameters such as electrode ...

11

A Novel Electrochemical Immunosensor for Detection of AngiotensinII at a Glass Carbon Electrode Modified by Carbon Nanotubes/Chitosan Film

A Novel Electrochemical Immunosensor for Detection of AngiotensinII at a Glass Carbon Electrode Modified by Carbon Nanotubes/Chitosan Film

... A novel electrochemical competitive immunosensor was successfully developed for the detection AngiotensinII using the glass carbon electrode (GCE) modified with the single-walled carbon nanotubes/chitosan ...

11

Show all 8066 documents...

Related subjects