Goldmann applanation tonometry

Goldmann applanation tonometry (GAT) is the standard for

Goldmann applanation tonometry (GAT) is the standard for

... Contour Tonometry after Laser In Situ Keratomileusis Claude Kaufmann, 1 Lucas ...by Goldmann applanation tonometry ...contour tonometry (DCT) is a novel measur- ing technique, designed ...

5

Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry

Tonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry

... Conclusion: GAT and DCT seem to be equally valuable in IOP determination in postsurgical central corneal edema, although large differences between both methods are present in individual patients. IOP evaluation in ...

5

Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature

Comparison of Goldmann applanation tonometry and Pascal dynamic contour tonometry in relation to central corneal thickness and corneal curvature

... Purpose: The aim of the study was to assess the influence of central corneal thickness (CCT) and corneal curvature in tonometry measurements taken by Goldmann applanation tonometry (GAT) and ...

8

Utilizing the principles of Gagne’s nine events of instruction in the teaching of Goldmann Applanation Tonometry

Utilizing the principles of Gagne’s nine events of instruction in the teaching of Goldmann Applanation Tonometry

... Introduction Tonometry is a diagnostic test that measures intraocular pressure (IOP), the fluid pres- sure inside the ...of tonometry currently available, with Goldmann Applanation ...

7

Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma

Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle Glaucoma

... Tomography. Goldmann-applanation tonometry (GAT) in the untreated state was recorded and Goldmann-correlated (IOPg) and corneal-compensated IOP (IOPcc) were obtained using the ...

7

Dynamic Contour Tonometry, Tono Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies

Dynamic Contour Tonometry, Tono Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies

... of Goldmann applanation tonometry (GAT) has been shown to depend on several biomechanical properties of the ...Newer tonometry devices ...

10

Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group

Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group

... So far, Goldmann applanation tonometry (GAT) is considered as a worldwide accepted gold standard for IOP measurement In clinical practice [5]. Recently, several new methods have been devised, in ...

10

Rebound Tonometry in Cataract Surgery: Comparison with Goldmann Applanation Tonometry

Rebound Tonometry in Cataract Surgery: Comparison with Goldmann Applanation Tonometry

... Concerning the comparison between RT before and after GAT measurement, the results demonstrated that the applanation tonometry does not affect subse- quent measurements with rebound tonometry. ...

11

Systematic review of the agreement of tonometers with Goldmann applanation tonometry

Systematic review of the agreement of tonometers with Goldmann applanation tonometry

... We identified a large body of evidence comparing tonometers to GAT. However, poor reporting limited the assessment of the quality of the included studies and the synthesis of the evidence. The results of this study ...

36

Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo

Goldmann applanation tonometry error relative to true intracameral intraocular pressure in vitro and in vivo

... measure applanation IOP at two averaged measurements each with the Perkins ...on applanation tonometry which are demonstrated in the cadaver eye portion of the study described ...

9

Goldmann tonometry tear film error and partial correction with a shaped applanation surface

Goldmann tonometry tear film error and partial correction with a shaped applanation surface

... correcting applanation tonometry surface; gaT, goldmann applanation tonometer; glMe, general linear ...in Goldmann applanation tonometry are clinically significant at an ...

8

Applanation and Air-puff Tonometry: A Comparative Study

Applanation and Air-puff Tonometry: A Comparative Study

... with Goldmann applanation tonometry did not occur during the present study’s IOP-air-puff or ORA-IOPcc ...air-puff tonometry is noninvasive and more comfortable for patients than conventional ...

6

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

... the Goldmann applanation tonometer, whilst the com- parative study of the PT100 and the Goldmann applanation tonometer done by Salim et al 11 had a large variation in age among the recruited ...

8

Goldmann and error correcting tonometry prisms compared to intracameral pressure

Goldmann and error correcting tonometry prisms compared to intracameral pressure

... Goldmann Applanation Tonometry (GAT) to measure Intraocular pressure (IOP) today remains the gold stand- ...modified applanation surface GAT (or CATS) prism to the traditional flat GAT prism ...

9

Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

Intraocular pressure and ocular pulse amplitude using dynamic contour tonometry and contact lens tonometry

... and Goldmann Tonometry. Before measurements, the subjects received local anesthesia with eye drops. For the measurement with the DCT, the subjects were placed at the slitlamp and the head of the DCT was ...

7

Goldmann tonometer error correcting prism: clinical evaluation

Goldmann tonometer error correcting prism: clinical evaluation

... glaucoma, tonometry, Goldmann, IOP, intraocular pressure, appalnation tonometer, corneal biomechanics, CATS tonometer, CCT, central corneal thickness, tonometer error Introduction Goldmann ...

6

Non-Invasive Ocular Rigidity Measurement: A Differential Tonometry Approach

Non-Invasive Ocular Rigidity Measurement: A Differential Tonometry Approach

... that Goldmann applanation tonometry (GAT) geometrically deforms the corneal apex and displaces volume from the anterior segment whereas Dynamic Contour Tonometry (DCT) does not, we aimed at ...

6

A comparison of NCT, Goldman application tonometry values with and without fluorescein

A comparison of NCT, Goldman application tonometry values with and without fluorescein

... pressure, Goldmann applanation tonometry, noncontact tonometry, central corneal thickness, refractive value Introduction Glaucoma is defined as an optic neuropathy of multifactorial origin ...

6

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

... the tonometry literature, namely: “Is Perkins an acceptable alternative to Goldmann?” Our results show a suitably compact grouping of difference values, not just within the defined Bland–Altman limits of ...

6

COMPARISON OF DYNAMIC CONTOUR TONOMETRY (PASCAL ) WITH PNEUMOTONOMETRY AND GOLDMANN TONOMETRY

COMPARISON OF DYNAMIC CONTOUR TONOMETRY (PASCAL ) WITH PNEUMOTONOMETRY AND GOLDMANN TONOMETRY

... Measurements were always carried out by the same person, only one eye per patient was includ- ed, and both the order of the tonometers and the eye selected for examination were random. Three measurements were conducted ...

5