• No results found

HVDC grid

Investigation of the impact of interoperability of voltage source converters on HVDC grid fault behaviour

Investigation of the impact of interoperability of voltage source converters on HVDC grid fault behaviour

... contributions are shown in Figure 3. From the converters volt- age and current responses, the three stages that were described in section 2 can be distinguished. At first, all converters present a steep current increase ...

6

Simulation Studies For Mmc–Hvdc Grid Using Ieee-39-Bus System By Enhanced Dc Voltage Droop-Control With Active Filters

Simulation Studies For Mmc–Hvdc Grid Using Ieee-39-Bus System By Enhanced Dc Voltage Droop-Control With Active Filters

... dc grid transfer functions are defined and ...the HVDC grid and its host ac ...VSC– HVDC grid with ...the HVDC-AC system to reach a new steady state after transient ...Terms: ...

5

A review of the protection for the multi-terminal VSC-HVDC grid

A review of the protection for the multi-terminal VSC-HVDC grid

... dc grid, the DCCBs are installed on each line terminal as shown in ...VSC-HVDC grid, the protection for the transmission line should identify the fault line reliably and ...VSC-HVDC ...

11

DC/DC converters based on hybrid MMC for HVDC grid interconnection

DC/DC converters based on hybrid MMC for HVDC grid interconnection

... independent HVDC grid sections. It is consisted of a DC grid section connecting to an offshore wind farm, DC Grid 2 and DC Grid 3 with similar or different voltage ...

6

A reliability evaluation of offshore HVDC grid configuration options

A reliability evaluation of offshore HVDC grid configuration options

... entire HVDC grid sections ...DC grid into distinct sections post fault, each of which would have a capacity within the loss of infeed limits of any connected onshore AC ...faulted grid sub- ...

10

Enhancing frequency stability by integrating nonconventional power sources through multi-terminal HVDC grid

Enhancing frequency stability by integrating nonconventional power sources through multi-terminal HVDC grid

... DC grid benchmark adapted for frequency stability studies and implemented in Matlab/Simulink simulation ...modified grid includes 5-terminal HVDC grid with two offshore wind farms and three AC ...

27

Review on A Step-Up Resonant Converter for HVDC Grid Connected Renewable Energy Sources

Review on A Step-Up Resonant Converter for HVDC Grid Connected Renewable Energy Sources

... and HVDC grid, it is a promising option to connect the renewable energy sources to the HVDC grid with a pure dc system, in which high-power high- voltage step-up dc-dc converters are the key ...

5

HVDC GRID CONNECTION PROBLEMS & SOLUTIONS

HVDC GRID CONNECTION PROBLEMS & SOLUTIONS

... methodsfor grid-connected parameters are proposed ...all grid- connected Parameter but may be of most importance in high-voltage dc (HVDC) ...

6

HVDC Grid Segmentation Analysis for Blackouts Reduction

HVDC Grid Segmentation Analysis for Blackouts Reduction

... Segmentation of large AC systems through DC links introduces a new concept that utilizes the advantages of direct current transmission to improve network reliability and increase power transfer capacity. Technical ...

14

Insights on the provision of frequency support by wind power and the impact on energy systems

Insights on the provision of frequency support by wind power and the impact on energy systems

... This paper incorporates three key concepts, pitch de-loading, rotor over-speeding, and electrical torque over-loading to extract KE to enable wind power frequency support. These methods are applied by supplementary ...

10

Overview of HVDC Technology

Overview of HVDC Technology

... based HVDC schemes rely on the AC side protection detecting and de-energising the ...multiterminal HVDC systems. Without DC breakers the multiterminal HVDC grid is what some call regional, in ...

32

Review of Power Converters for High Voltage Direct Current (HVDC) Transmission

Review of Power Converters for High Voltage Direct Current (HVDC) Transmission

... Most HVDC systems in operation today are based on commutated converter. According to Mathur et al in 2002, the basic Line Commutated Converters (L.C.C) configuration is made up of bridge rectifier, having six ...

10

Cost- benefit Analysis of installation of tapping station on bipole VSC-HVDC transmission system

Cost- benefit Analysis of installation of tapping station on bipole VSC-HVDC transmission system

... The analysis procedure is based on the assisting unit approach. In the first stage, the reliability models of subsystems 1 to 8 are developed as shown in table 1. This table shows the probability of each state and the ...

10

Open access simulation toolbox for the grid connection of offshore wind farms using multi-terminal HVDC networks

Open access simulation toolbox for the grid connection of offshore wind farms using multi-terminal HVDC networks

... is regulated using the d-axis. An active power vs DC voltage droop has been included to the d-axis outer loop for DC voltage regulation and power flow sharing. A PLL is also included to generate reference phase angles. ...

6

Frequency Monitoring of Power Systems with Off-Shore Wind Generation Using VSC-HVDC

Frequency Monitoring of Power Systems with Off-Shore Wind Generation Using VSC-HVDC

... A sudden decrease of Load C results in the frequency to be over the upper acceptable limit (50.2 Hz). The simulation results for the sudden load decrease scenario are shown in Fig. 4, while the communication delay of ...

6

Analysis of Ionized Field Under HVDC Transmission Lines Within the Influences of Suspended Particles

Analysis of Ionized Field Under HVDC Transmission Lines Within the Influences of Suspended Particles

... Abstract—The ionized field under HVDC transmission lines have an impact on environment and people. With the industrial pollution and environment deterioration, the suspended particles that will influence the ionized ...

12

Reactive Power Control and harmonic elimination in VSC HVDC system

Reactive Power Control and harmonic elimination in VSC HVDC system

... conventional HVDC transmission system. The VSC based HVDC transmission system mainly consists of two converter stations connected by a DC ...based HVDC transmission system. In this paper a 75kM long ...

5

Steady and transient state performance of HVDC transmission system based on hybrid multilevel VSC with ac side cascaded  H bridge cells

Steady and transient state performance of HVDC transmission system based on hybrid multilevel VSC with ac side cascaded H bridge cells

... proposed HVDC transmission system requires a voltage-balancing scheme that ensures that the voltages across the H-bridge cells are maintained at Vdc/n under steady and transient state operation, where Vdc is the ...

10

A Design of Droop Control for Multi terminal HVDC of Offshore Wind Farms with Three Wire Bipolar Transmission

A Design of Droop Control for Multi terminal HVDC of Offshore Wind Farms with Three Wire Bipolar Transmission

... new HVDC transmission lines, converting exiting HVAC systems into HVDC can solve many problems associated with new HVDC lines ...monopole HVDC but facing a problem in ground ...bipole ...

8

The Insulation of HVDC Extruded Cable System Joints. Part 1: Review of Materials, Design and Testing Procedures

The Insulation of HVDC Extruded Cable System Joints. Part 1: Review of Materials, Design and Testing Procedures

... An alternative FG solution employed also to reach higher voltages (500-600 kV and above, see Section 1), with only small effects on size and weight, and an additional dynamic self-adjustment of the stress control ...

9

Show all 6314 documents...