• No results found

Immunochromatographic strip

Development and evaluation of an immunochromatographic strip for rapid detection of porcine hemagglutinating encephalomyelitis virus

Development and evaluation of an immunochromatographic strip for rapid detection of porcine hemagglutinating encephalomyelitis virus

... the immunochromatographic strip were determined to be 100% and ...tographic strip to ELISA and RT-PCR (Kappa = ...the strip test to be close to, or slightly less than, that of ELISA and ...the ...

11

Development of an Immunochromatographic Strip for Simple Detection of Penicillin-Binding Protein 2′

Development of an Immunochromatographic Strip for Simple Detection of Penicillin-Binding Protein 2′

... Preparation of the immunochromatographic strip. Anti-PBP2⬘ monoclonal IgM (clone 1G12) and anti-mouse IgG antibody (Vector Laboratories, Inc., Burlingame, CA) were immobilized on a 2.5- by 0.5-cm ...

6

Development of an Immunochromatographic Strip for Rapid Detection of H9 Subtype Avian Influenza Viruses

Development of an Immunochromatographic Strip for Rapid Detection of H9 Subtype Avian Influenza Viruses

... the immunochromatographic strip. The immunochromato- graphic strip was composed of four components, a sample pad, a conjugate pad, a nitrocellulose membrane, and an absorbent pad, as illustrated in ...

6

Immunochromatographic strip biosensor application for early diagnosis of cancer by urinary carcinoembryonic antigen

Immunochromatographic strip biosensor application for early diagnosis of cancer by urinary carcinoembryonic antigen

... Immunochromatographic strip tests (ISTs) are simple, rapid, in-field and cheap assays and their results providing simple qualititative detection without the need of skilled personnel (Cui et ...

5

Development and validation of a prokaryotically expressed foot and mouth disease virus non structural protein 2C'3AB based immunochromatographic strip to differentiate between infected and vaccinated animals

Development and validation of a prokaryotically expressed foot and mouth disease virus non structural protein 2C'3AB based immunochromatographic strip to differentiate between infected and vaccinated animals

... an immunochromatographic strip with non-structural protein (NSP) 2C’3AB was developed and validated to differentiate foot-and-mouth disease infected from vaccinated ...the strip in comparison with ...

9

Rapid and Quantitative Detection of Zoonotic Influenza A Virus Infection Utilizing Coumarin-derived dendrimer-based Fluorescent Immunochromatographic Strip Test (FICT)

Rapid and Quantitative Detection of Zoonotic Influenza A Virus Infection Utilizing Coumarin-derived dendrimer-based Fluorescent Immunochromatographic Strip Test (FICT)

... using immunochromatographic strip test ...test strip [31-33]. The test strip for ICT consists of a con- jugate pad, sample pad, nitrocellulose membrane, and absorbent ...agnostic strip ...

11

A Rapid Quantitative Determination Method of AFP Concentration with Gold Immunochromatographic Strip

A Rapid Quantitative Determination Method of AFP Concentration with Gold Immunochromatographic Strip

... Gold immunochromatographic strip is based on colloidal gold-labeled and chromatographic technology for the rapid ...typical immunochromatographic strip was constructed in the form of sandwich ...

8

A Novel Image Methodology for Interpretation of Gold Immunochromatographic Strip

A Novel Image Methodology for Interpretation of Gold Immunochromatographic Strip

... gold immunochromatographic strip, which is based on the image scheme, is ...gold immunochromatographic strip signal is taken by high gray level resolution area array Charge Coupled Device ...

8

Development of an immunochromatographic strip for the serodiagnosis of Theileria infection in sheep

Development of an immunochromatographic strip for the serodiagnosis of Theileria infection in sheep

... [10]. This method is reliable for the detection of infec- tion in acute cases, but it is limited for the diagnosis of chronic cases because of the low number of parasitemia in ruminants [11]. Additionally, it is ...

6

Accuracy of clinical criteria and an immunochromatographic strip test for dengue diagnosis in a DENV 4 epidemic

Accuracy of clinical criteria and an immunochromatographic strip test for dengue diagnosis in a DENV 4 epidemic

... The development of more sensitive point-of-care tests for dengue diagnosis to act as a screening tool remains a challenge, especially for endemic countries, where the prevalence of secondary cases is high. In summary, we ...

9

Monoclonal antibody based colloid gold immunochromatographic strip for the rapid detection of Tomato zonate spot tospovirus

Monoclonal antibody based colloid gold immunochromatographic strip for the rapid detection of Tomato zonate spot tospovirus

... GICA strip could specifically recognize the TZSV, without cross reaction with CMV, TMV, SMV, TSWV and ...GICA strip had the detection limit of 1:810 diluted from sap of the TZSV-infected leaf tissue but the ...

9

Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus

Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus

... An ICS test for detecting DEV-specific antibodies was developed. A sandwich immunoreaction was performed on the ICS [16,29,30]. Briefly, the ICS assembly consists of a sample pad, a conjugate pad, a nitrocellulose ...

8

Rapid immunoassays for detection of anabolic nortestosterone in dietary supplements

Rapid immunoassays for detection of anabolic nortestosterone in dietary supplements

... an immunochromatographic strip were designed for a rapid detection of nortestosterone in dietary ...particle-based immunochromatographic strip provided in semi-quantitative test a visual ...

6

A Small Size Three-Band Multi-Functional Antenna for LTE/GSM/UMTS/WiMAX
 Handsets

A Small Size Three-Band Multi-Functional Antenna for LTE/GSM/UMTS/WiMAX Handsets

... of strip-1, strip-2, Br-1, Br-2 and S-strip. Strip-1, strip-2, Br-1and Br-2 are on the front side, while S-strip is on the back side of the ...(c)). Strip-2 and ...

6

Electronic and Magnetic Properties of Graphene Möbius Strips: Density Functional Theory Approach

Electronic and Magnetic Properties of Graphene Möbius Strips: Density Functional Theory Approach

... Fig. 5(b)] at which the density of states for spin up electrons becomes equal to that for spin down. When the electric field strength is greater than this critical value, the density of states for spin up electrons ...

6

Bandwidth Enhancement Techniques using Stacked Microstrip Patch Antennas

Bandwidth Enhancement Techniques using Stacked Microstrip Patch Antennas

... micro strip patch elements Microstrip patch antennas radiate primarily because of the fringing fields between the patch edge and the ground ...micro strip patch antenna the substrates with higher dielectric ...

5

Prediction of Work Roll Initial Crown according to Desired Strip Profile in Hot Rolling

Prediction of Work Roll Initial Crown according to Desired Strip Profile in Hot Rolling

... hot strip mill of MSC illustrated in Figure 2. In the selected hot strip mill, slabs from the slab caster are rolled into strips, with a corresponding reduction in thickness from an input value of 203 mm to ...

10

Field Evaluation of a Rapid Immunochromatographic Test for Tuberculosis

Field Evaluation of a Rapid Immunochromatographic Test for Tuberculosis

... The objective of the study was to evaluate the performance of the ICT Tuberculosis test for the diagnosis of active pulmonary TB PTB with whole blood, plasma, and serum from patients sus[r] ...

5

Casting of Clad Strip by a Vertical Type Twin Roll Caster

Casting of Clad Strip by a Vertical Type Twin Roll Caster

... alloy strip to another aluminum alloy strip is reported to be very difficult due to surface oxidation of the 5182 strip caused by the Mg alloying ...5182 strip negatively impacts bonding ...

7

Analysis on Design of Flat SLAB Structure

Analysis on Design of Flat SLAB Structure

... 1) column strip :column strip means a design strip having a width of 0.25 i,, but not greater than 0.25 1, on each side of the column centre-line, where i, is the span in the direction [r] ...

12

Show all 1246 documents...

Related subjects