Implant Abutment

Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis

Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis

... between implant and suprastructure, implant neck design and implant surface ...successful implant treatment may include marginal bone loss less than 1 to ...after implant loading and ...

13

Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study

Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study

... contacting implant-abutment surface can cause axial displacement of the abutment into the implant bore and the length of the elongated screw is shortened microscopically, lead- ing to the loss ...

9

Comparative Study on Material Combinations of Various Dental Implant abutment Systems

Comparative Study on Material Combinations of Various Dental Implant abutment Systems

... at implant-bone interface, which benefits the selection of implant-abutment system materials; Methods: The simplified models of mandibular bone, implant and mandibular molar were established ...

6

Marginal bone loss around dental implants with conical and hexagonal implant-abutment interface: A literature review

Marginal bone loss around dental implants with conical and hexagonal implant-abutment interface: A literature review

... of implant-abutment connection does not create adverse conditions for osseo- integration was confirmed in 50 patients with 69 ANKY- LOS implants placed in a subcrestal position and healed with the open ...

6

Comparative evaluation of the microgap of premachined Titanium and Zirconia abutments at the implant-abutment interface before and after cyclic loading: An In Vitro study

Comparative evaluation of the microgap of premachined Titanium and Zirconia abutments at the implant-abutment interface before and after cyclic loading: An In Vitro study

... One of the limitations of the present study was that only a 45-day simulation of cyclic loading was performed. A longer loading period may affect the implant-abutment interface differently. The effect of ...

112

Comparative Evaluation of Force Transmission and Wear Resistance between Titanium and Zirconia Abutment at Implant Abutment Interface after Cyclic Loading: An Invitro Study

Comparative Evaluation of Force Transmission and Wear Resistance between Titanium and Zirconia Abutment at Implant Abutment Interface after Cyclic Loading: An Invitro Study

... custom implant abutments with CAD/CAM commercially fabricated Zirconia implant ...of implant abutment specimens which were custom made Pr abutments and the control group consists of CAD/CAM ...

162

Comparative Evaluation of Fracture Resistance of Pre Fabricated Dental Implant Abutment Connections: An In Vitro Study

Comparative Evaluation of Fracture Resistance of Pre Fabricated Dental Implant Abutment Connections: An In Vitro Study

... in abutment preparation without damaging the head of the ...the implant. Interestingly the connection design of equinox implant system has ( TC ) triangular connection design with the thin rim ...

101

Comparative evaluation of the microgap at the implant-abutment interface with premachined and customized laser-sintered cobalt-chromium abutments: An In Vitro study

Comparative evaluation of the microgap at the implant-abutment interface with premachined and customized laser-sintered cobalt-chromium abutments: An In Vitro study

... the implant-abutment ...the implant-customized abutment interface could reduce afore mentioned complications by controlling the ...the implant-abutment interface microgap for ...

170

Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment

Development of a new quantitative gas permeability method for dental implant-abutment connection tightness assessment

... dental implant-abutment remaining flow was lower after key screwing compared to hand screwing (p = ...the implant-abutment flow after key screwing showed to remain different from the negative ...

8

Comparative Evaluation of the Wear Resistance of Two Different Implant Abutment Materials after Cyclic Loading: An In Vitro Study

Comparative Evaluation of the Wear Resistance of Two Different Implant Abutment Materials after Cyclic Loading: An In Vitro Study

... the implant abutment ...in abutment connection, suitability for one-stage implant installation and single tooth restoration, higher stability and restoration to lateral loads due to lower ...

137

Analysis of the interface formed by premachined cobalt chromium implant abutment base with cast on cobalt chromium alloy before and after simulated porcelain firing: An In Vitro study

Analysis of the interface formed by premachined cobalt chromium implant abutment base with cast on cobalt chromium alloy before and after simulated porcelain firing: An In Vitro study

... premachined implant abutment base at its connection with cast alloy that had been provided by the manufacturer to provide mechanical retention between the premachined implant abutment base and ...

169

COMPARATIVE STUDY OF VERTICAL MARGINAL FIT ON IMPLANT ABUTMENT USING METAL CERAMIC CROWNS, FULL CONTOUR ZIRCONIA CROWNS (CAD/CAM) AND VENEERED ZIRCONIA CROWNS (CAD/CAM) (AN IN VITRO STUDY)

COMPARATIVE STUDY OF VERTICAL MARGINAL FIT ON IMPLANT ABUTMENT USING METAL CERAMIC CROWNS, FULL CONTOUR ZIRCONIA CROWNS (CAD/CAM) AND VENEERED ZIRCONIA CROWNS (CAD/CAM) (AN IN VITRO STUDY)

... system:-The implant abutment was covered by the scan spray to reduce the problem during the scan process due to the high reflective material of the implant abutment and give clear scan image ...

12

The influence of implant–abutment connection on the screw loosening and microleakage

The influence of implant–abutment connection on the screw loosening and microleakage

... of abutment screw after the cyclic loading showed no statistically significant difference among the ...of abutment screw. Actually, implantabutment connection after the removal of ...

6

The fracture strength by a torsion test at the implant-abutment interface

The fracture strength by a torsion test at the implant-abutment interface

... the implant prosthesis, the im- plant inclination, and the loading ...clinical implant/abutment joint strength is required and ISO 14801 is used as their fatigue strength test ...the ...

5

Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss

Comparisons of maximum deformation and failure forces at the implant–abutment interface of titanium implants between titanium-alloy and zirconia abutments with two levels of marginal bone loss

... dental implant without marginal bone loss will result in stress concentration at the implantabutment interface, which is the fulcrum (pivot) of the ...the abutment and onto the implant ...

10

Original Article A microbiological assessment of peri-implant sites and implant-abutment interfaces in diabetic and healthy individuals

Original Article A microbiological assessment of peri-implant sites and implant-abutment interfaces in diabetic and healthy individuals

... the implant. To collect samples from the implant-abutment interface (IAI), the cover screws were removed, and paper points were rotated inside the implants for 30 sec- ...the implant site with ...

8

Effect of different angulations and collar lengths of conical hybrid implant abutment on screw loosening after dynamic cyclic loading

Effect of different angulations and collar lengths of conical hybrid implant abutment on screw loosening after dynamic cyclic loading

... to abutment angulation, into three groups: GI 0° abutment, GII 15° abutment, and GIII ...Each implant and abutment assembly was positioned vertically in the center of the acrylic resin ...

12

Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique

Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique

... the implant and prosthetic components ranges between 1 to 49 µm depending on the type of selected abutment ...several abutment types at the I-A interface using radiotracing ...three abutment ...

8

Silver-chlorexidine-liquid is effective to sterilize screw retaining abutment to implant space in already inserted fixture: An in vitro study

Silver-chlorexidine-liquid is effective to sterilize screw retaining abutment to implant space in already inserted fixture: An in vitro study

... Materials and methods: A total of eight implants were used (Edierre Implant System, Edierre SpA, Genova, Italy). The SRAIS of four fixtures were firstly contaminated with 10 micro-litres of pure bacteria (i.e. ...

5

Comparative Evaluation of Tensile Bond Strength of Luting Cements with Effect of Abutment Angulation on Retention of Cement-Retained Implant Supported Restorations - An In Vitro Study.

Comparative Evaluation of Tensile Bond Strength of Luting Cements with Effect of Abutment Angulation on Retention of Cement-Retained Implant Supported Restorations - An In Vitro Study.

... of abutment size and luting cement type on the uniaxial retention force of implant-supported ...titanium implant abutments and matching Cera One gold cylinders were ...of implant abutments and ...

129