• No results found

implantable electronic device

Imaging topography and morphometry of persistent left superior caval vein and its variations, detected on cardiac implantable electronic device implantation

Imaging topography and morphometry of persistent left superior caval vein and its variations, detected on cardiac implantable electronic device implantation

... cardiac implantable electronic device (CIED) placement, and whose successful completion depends on favourable morphometric parameters of these ...

8

A rare vascular anomaly in the form of double left brachiocephalic vein detected incidentally during cardiac implantable electronic device (CIED) placement

A rare vascular anomaly in the form of double left brachiocephalic vein detected incidentally during cardiac implantable electronic device (CIED) placement

... Figure 2. A–D. Stages of the cardiac implantable electronic device implantation procedure described in this paper. A. A venogram illustrating the site of difficulties in lead advancement through the ...

5

Morphometric parameters of cardiac implantable electronic device (CIED) pocket walls observed on device replacement

Morphometric parameters of cardiac implantable electronic device (CIED) pocket walls observed on device replacement

... cardiac implantable electronic device (CIED) capsules ...18-year-old device pocket with evidence of capsule wall calcification, during a second-time cardiac implantable ...

7

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

Selected clinical challenges of a supraclavicular cephalic vein in cardiac implantable electronic device implantation

... Background: Supraclavicular variations of the cephalic vein (CV) are detected sporadically. A somewhat more common finding is a CV variation with the typical course of the main vessel but with an additional ...

6

Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection

Approach to Diagnosis of Cardiovascular Implantable Electronic Device Infection

... ABSTRACT Device infection remains a significant challenge as clinical indications for cardiovascular implantable electronic device (CIED) therapy continue to expand beyond the prevention and ...

9

Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

... cardiac implantable electronic device (CIED) implantation have increased in the last ...the device, there are multiple sources of potential expense; prolonged courses of antibiotics may be ...

13

Review of cardiac implantable electronic device related infection

<div>Review of cardiac implantable electronic device related infection</div>

... Cardiac implantable electronic devices (CIEDs) are being used more and more often ...cardiac implantable electronic device, infection, pacemaker, endocarditis ...

10

Axillary vein spasm during cardiac implantable electronic device implantation

Axillary vein spasm during cardiac implantable electronic device implantation

... Background: The technique of axillary vein (AV) or subclavian vein (SV) puncture has become an important alternative to cephalic vein (CV) cutdown as an appro- ach allowing cardiac lead introduction into the venous ...

7

Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement

Vasoconstrictive responses of the cephalic vein during first-time cardiac implantable electronic device placement

... Figure 1. Histological slide containing longitudinal sections of cephalic vein segments: the segment upstream of the valve (A) and at the valve base (B). Masson’s trichrome stain visualises alternating collagen fibres ...

7

Radiotherapy-induced cardiac implantable electronic device disorders in cancer patients.

Radiotherapy-induced cardiac implantable electronic device disorders in cancer patients.

... the electronic components of a cardiac implantable electronic device (CIED) resulting in malfunction and/or ...shorter device-age at the time of radiotherapy compared to those who did ...

16

Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

Cardiac implantable electronic device infection due to Mycobacterium species: a case report and review of the literature

... last device related ...epicardial device implantations [19, 23, 28, 29, ...the device or pocket at the time of insertion or during surgical manipu- ...

10

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

Clinical implications of cephalic vein morphometry in routine cardiac implantable electronic device insertion

... cardiac device/lead placement procedure was conducted according to the local protocol: a linear 4–6 cm (depending on the size of the implanted device) incision along the deltopectoral groove was made under ...

7

Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center

Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center

... Following device interrogation via appropriate program- ming devices, MediConnect ® software was employed for digital data transfer and for generation of medical ...the electronic patient manage- ment ...

9

Original Article Prospective randomized study of axillary venous access with or without fluoroscopy-guided in cardiovascular implantable electronic device implantation

Original Article Prospective randomized study of axillary venous access with or without fluoroscopy-guided in cardiovascular implantable electronic device implantation

... (PM), implantable car- dioverter defibrillators (ICD), and cardiac resyn- chronization therapy pacemakers/defibrillators (CRT-P/CRT-D) were prospectively evaluated using axillary vein puncture as the primary ap- ...

6

Clinical evidence guided network pharmacology analysis reveals a critical contribution of β1 adrenoreceptor upregulation to bradycardia alleviation by Shenxian Shengmai

Clinical evidence guided network pharmacology analysis reveals a critical contribution of β1 adrenoreceptor upregulation to bradycardia alleviation by Shenxian Shengmai

... Cardiac implantable electronic device (CIED) and taking chemical ...addition, device infection has be- come a major problem which results in another huge burden on the patients who paid an ...

13

Intrapulmonal dislocation of a totally implantable venous access device

Intrapulmonal dislocation of a totally implantable venous access device

... by intra- and postoperative x-ray (figure 1). Moreover, the system worked properly since then, excluding a surgical problem in the presented case. The reason for the perfora- tion remains obscure. CT scan showed no local ...

6

Infections of Cardiac Implantable Electronic Devices: Diagnosis and Approach

Infections of Cardiac Implantable Electronic Devices: Diagnosis and Approach

... After the diagnosis of infection, should be initiated empirical antibiotic therapy. Then, this therapy will be modified according to the results of blood cultures. The initial empiric antibiotic should be vancomycin. If ...

8

Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis

Infections of cardiac implantable electronic devices: Epidemiology, classification, treatment, and prognosis

... of implantable cardiac electronic devices (ICEDs) leads to a substantial growth of a cohort of patients in whom complications of such a therapy ...cardiac device infection (CDI) is estimated at ...

8

The oral cavity is not a primary source for implantable pacemaker or cardioverter defibrillator infections

The oral cavity is not a primary source for implantable pacemaker or cardioverter defibrillator infections

... diac device infections were investigated by culture and in this study Staphylococcus aureus and coagulase-negative staphylococci were most frequently isolated ...

7

The Design and Development of Interpretation and Execution Program for EDDL

The Design and Development of Interpretation and Execution Program for EDDL

... Device-related EDD and EDDL are designed for industrial automation applications, including conventional digital and analog I/O modules, motion controllers, man-machine interfaces, sensors, closed-loop controllers, ...

7

Show all 10000 documents...

Related subjects