• No results found

lateral resolution

Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography

Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography

... the resolution target for PAT system is ...the lateral resolution of PAT system in a medium, commercially available USAF 1951 target needs modification for practical ...optical resolution ...

11

Method for Improving the Lateral Resolution of Near Infrared (NIR) Single Optods: Application to Subcutaneous Vein Detection and Localization

Method for Improving the Lateral Resolution of Near Infrared (NIR) Single Optods: Application to Subcutaneous Vein Detection and Localization

... the lateral resolution and consequently in the localization accuracy of the small absorption volume embedded deep within the ...spatial resolution is the resultant of the differential measurements of ...

6

The 3D OrbiSIMS—label free metabolic imaging with subcellular lateral resolution and high mass resolving power

The 3D OrbiSIMS—label free metabolic imaging with subcellular lateral resolution and high mass resolving power

... combination with the ToF mass analyser usually 0.6 ns long ion pulses are achieved if bunching is applied. Longer pulse durations of 1.5 -150 ns can be obtained in un-bunched operation. In addition, a new 20 keV argon ...

18

Selecting the tip electron orbital for scanning tunneling microscopy imaging with sub ?ngstrom lateral resolution

Selecting the tip electron orbital for scanning tunneling microscopy imaging with sub ?ngstrom lateral resolution

... best lateral resolution can be obtained at small positive sample biases and distances around 3 ˚ A, but four-fold splitting can, in principle, be resolved at very small gap spacings in some ranges of the ...

7

The 3D OrbiSIMS—label free metabolic imaging with subcellular lateral resolution and high mass resolving power

The 3D OrbiSIMS—label free metabolic imaging with subcellular lateral resolution and high mass resolving power

... This protocol was developed in conjunction with the development of the 3D OrbiSIMS instrument as described in the publication “The 3D OrbiSIMS – A new Method for Label-Fee Metabolic Imaging with Sub-Cellular ...

5

The 3D OrbiSIMS—label free metabolic imaging with subcellular lateral resolution and high mass resolving power

The 3D OrbiSIMS—label free metabolic imaging with subcellular lateral resolution and high mass resolving power

... Putative annotation of 3'-sulfoGalβ-N-acyl-sphing-4-enine species detected in the negative ion image of the mouse hippocampus in Figure 3D main text... Chemical formula Mass of [M-H]- io[r] ...

23

Single cell analysis: visualizing pharmaceutical and metabolite uptake in cells with label free 3D mass spectrometry imaging

Single cell analysis: visualizing pharmaceutical and metabolite uptake in cells with label free 3D mass spectrometry imaging

... the lateral resolution is limited by the diameter of the Gaussian -shaped ion beam, the full width half maximum (FWHM) lateral resolution, which is equivalent to ...

21

Focusing system for an ultrasonic transducer

Focusing system for an ultrasonic transducer

... hemisphere piezoelectric crystal having a non-uniform beam width and a better lateral resolution than the plane transducer due to reduced beam width in the foc... Objective of Research T[r] ...

36

Determining the chronology of deposition of natural fingermarks and inks on paper using secondary ion mass spectrometry

Determining the chronology of deposition of natural fingermarks and inks on paper using secondary ion mass spectrometry

... It is also capable of producing high resolution chemical images by rastering the ion beam across the sample surface.17 ToF-SIMS has excellent lateral resolution capabilities, is particul[r] ...

13

4D Super-Resolution Microscopy with Conventional Fluorophores and Single Wavelength Excitation in Optically Thick Cells and Tissues

4D Super-Resolution Microscopy with Conventional Fluorophores and Single Wavelength Excitation in Optically Thick Cells and Tissues

... observed lateral chromatic shifts on the order of ,100 nm with our custom-built splitter, similar to that obtained with a commercial splitter-device (Optosplit II, Cairn, UK, data not ...and lateral ...

10

Optimising performance of a confocal fluorescence microscope with a differential pinhole

Optimising performance of a confocal fluorescence microscope with a differential pinhole

... axial resolution gains. Gains in the lateral direction were realised using techniques such as structured illumination microscopy (SIM) [10], lateral modulated excitation microscopy [11] and harmonic ...

12

The Effect of the Transducer Parameters on Spatial Resolution in Plane-Wave Imaging

The Effect of the Transducer Parameters on Spatial Resolution in Plane-Wave Imaging

... A method to improve the imaging quality in PWI with preserving the high frame rate is to use Compounded PWI (CPWI), where multiple steered unfocused plane waves are av- eraged to produce a single high quality image. This ...

5

Very Low Energy Scanning Electron Microscopy of Free Standing Ultrathin Films

Very Low Energy Scanning Electron Microscopy of Free Standing Ultrathin Films

... The first series of images of free standing thin foils of gold and carbon were obtained in the transmitted mode at landing energies from several keV down to 2 eV with a lateral resolution from 15 nm up to 30 ...

6

Could cone-beam computed tomography demonstrate the lateral accessory canals?

Could cone-beam computed tomography demonstrate the lateral accessory canals?

... The root canal morphology of some specimens near the apical regions were blurred when displayed in the ZS and FS modes (Fig. 5); therefore, Vertucci’s classification was only evaluated in the HZ mode; and LACs could not ...

8

Lateral fricatives and lateral emphatics in southern Saudi Arabia and Mehri

Lateral fricatives and lateral emphatics in southern Saudi Arabia and Mehri

... a lateral fricative (Steiner ...a lateral sibilant /ś/; this latter is similar in articulation to the Welsh double l in words such as Llanelli, llid and Lloyd, and represented in the International Phonetic ...

10

Model constraints on the anthropogenic carbon budget of the Arctic Ocean

Model constraints on the anthropogenic carbon budget of the Arctic Ocean

... with resolution, so does the simulated ...Higher resolution is also needed to capture local ...vertical resolution, subgrid-scale parameterizations, and adjustments to model parameters for viscosity ...

25

Morphological and physiological evidence of a synaptic connection between the lateral parabrachial nucleus and neurons in the A7 catecholamine cell group in rats

Morphological and physiological evidence of a synaptic connection between the lateral parabrachial nucleus and neurons in the A7 catecholamine cell group in rats

... central lateral (cl) LPB ...the lateral crescent (lcr), external medial (em) and external lateral (el) subnuclei, as la- beled neurons and neuritis were identified in these areas ...

10

Preliminary Experience with Onyx Embolization for the Treatment of Intracranial Dural Arteriovenous Fistulas

Preliminary Experience with Onyx Embolization for the Treatment of Intracranial Dural Arteriovenous Fistulas

... RESULTS: A total of 17 procedures were performed in 12 patients. In all of the cases, transarterial microcatheterization was performed, and Onyx-18 or a combination of Onyx-18/Onyx-34 was used. Eight patients were men. ...

7

Qualitative Assessment of Brain Anomalies in Adolescents with Mental Retardation

Qualitative Assessment of Brain Anomalies in Adolescents with Mental Retardation

... Intraclass correlation (ICC) statistics were used to calculate interobserver and intraobserver agreement. Between-group comparisons of checklist scores were assessed by using the 2-tailed Mann-Whitney U test. Total ...

7

Lateral photographs versus lateral cephalograms: role in assessment of craniofacial morphology

Lateral photographs versus lateral cephalograms: role in assessment of craniofacial morphology

... Although lateral cephalograms are the gold standard and have become an imperative to diagnosis and treatment planning in orthodontic patients, there have been rising concerns over unnecessary exposure to ...a ...

5

Show all 10000 documents...

Related subjects