• No results found

line intensities

Complexities of gamma ray line intensities from the lunar surface

Complexities of gamma ray line intensities from the lunar surface

... the line gamma rays induced by neutrons from the major elements ...both line gamma rays and continuum in spectra to estimate back- ground gamma rays and sensitivity of a detector ...of line gamma ...

7

Spectroscopic Diagnostic of Helium-Hydrogen RF Plasma under the Influence of Radiation Trapping

Spectroscopic Diagnostic of Helium-Hydrogen RF Plasma under the Influence of Radiation Trapping

... The emission or absorption of photons in a location depends on the radiation flux emitted from the rest of the plasma. Because atoms at a location influence each other through emission or absorption, a self-consistent ...

9

Benchmarking atomic data for astrophysics : Si III

Benchmarking atomic data for astrophysics : Si III

... Å line was not reported by these authors, so we have included a measurement that we have obtained for it from the HRTS observation described by Brekke et ...Sun intensities with those measured by the Skylab ...

11

Ionization Balance in the Rotating Radiation Belt Accompanying Complete Divertor Detachment in LHD

Ionization Balance in the Rotating Radiation Belt Accompanying Complete Divertor Detachment in LHD

... α line intensity os- cillates with a frequency of approximately 30 Hz, which is twice the frequency of the radiation belt rotation measured with the AXUVD ...the line intensity should take the maximum twice ...

5

MIPAS database: new HNO 3line parameters at 7.6 µm validated with MIPAS satellite measurements

MIPAS database: new HNO 3line parameters at 7.6 µm validated with MIPAS satellite measurements

... lines. Intensities measured for blended lines being most probably characterized by a reduced precision, the comparison be- tween line intensities reported in these two studies and those included in ...

10

SMS photograph based external quality assessment of reading and interpretation of malaria rapid diagnostic tests in the Democratic Republic of the Congo

SMS photograph based external quality assessment of reading and interpretation of malaria rapid diagnostic tests in the Democratic Republic of the Congo

... Methods: The EQA consisted of (i) 10 high-resolution printed photographs displaying cassettes with real-life results and multiple choice questions (MCQ) addressing individual health workers (HW), and (ii) a questionnaire ...

12

Simultaneous Measurement of Electron and Ion Temperatures with Helium-like Argon X-Ray Spectrum

Simultaneous Measurement of Electron and Ion Temperatures with Helium-like Argon X-Ray Spectrum

... the line intensity can be sepa- rated into three components which are respectively propor- tional to the densities of helium-like, hydrogen-like, and lithium-like ...the line intensities of singly ...

5

Beyond the Born-Oppenheimer approximation: high-resolution
overtone spectroscopy of H2D+ and D2H+

Beyond the Born-Oppenheimer approximation: high-resolution overtone spectroscopy of H2D+ and D2H+

... The organization of this paper is as follows. Section II presents a brief description of the experimental apparatus, with particular emphasis on the slit discharge source and recently implemented concentration modulation ...

38

Atomic data for astrophysics : Ni XII

Atomic data for astrophysics : Ni XII

... We present new large-scale R-matrix (up to n = 4) scattering calculations for the electron collisional excitation of Cl-like Ni xii . We used the intermediate-coupling frame transformation method. We compare predicted ...

8

Development and Optimization of Laser-Induced Breakdown Spectroscopy (LIBS) for Quantification of Carbon in Steel within UV/Visible Region

Development and Optimization of Laser-Induced Breakdown Spectroscopy (LIBS) for Quantification of Carbon in Steel within UV/Visible Region

... material, a short-lived (in the order of microseconds) high-temperature (a few eV) and density (10 16 −10 19 cm -3 ) plasma is generated. The fundamental concept of LIBS is similar to that of conventional plasma-based ...

5

Determining protoplanetary disk gas masses from CO isotopologues line observations

Determining protoplanetary disk gas masses from CO isotopologues line observations

... logues line luminosities of at least four orders of magnitudes over the same range of disk ...µm line intensities increase by a factor of a few in our grid, in agreement with what found by Woitke et ...

19

Assessment of the prozone effect in malaria rapid diagnostic tests

Assessment of the prozone effect in malaria rapid diagnostic tests

... test line intensity upon 10 × ...test line intensities, the distribution for the undiluted sample/brand combinations with pro- zone effect (n = 51) was as follows: a single ...2 line. Maximum ...

7

Understanding the Mg II and Hα spectra in a highly dynamical solar prominence

Understanding the Mg II and Hα spectra in a highly dynamical solar prominence

... We attempt to simulate the shape of the observed composite pro fi le in the following way. For each individual intensity peak we assume an identical isothermal – isobaric model which produces an unreversed pro fi le. Then ...

5

Determination of substitutional carbon content in rapid thermal chemical vapour deposited Si1 x yGexCy on Si (1 0 0) using Raman spectroscopy

Determination of substitutional carbon content in rapid thermal chemical vapour deposited Si1 x yGexCy on Si (1 0 0) using Raman spectroscopy

... Raman intensities of the carbon local modes and the Si-Si modes versus carbon content was ...peak intensities of these vibrational modes versus C content for samples with x ≤ ...

10

Controlling circular polarization of light emitted by quantum dots using chiral photonic crystal slabs

Controlling circular polarization of light emitted by quantum dots using chiral photonic crystal slabs

... experimental line FWHM is about five times greater than the calculated one (≈4 and ...the line sits on a background whose magnitude is about 9% from its peak intensity whereas the background in the ...

10

Peak Running Intensities of Professional Football

Peak Running Intensities of Professional Football

... In support of our hypothesis, the present study observed that the peak periods of acceleration/deceleration often occurred separately to the peak periods of speed (Figure 1), particularly for moving average windows of ...

277

Study of the Dielectric Variation Due To Phase Transformation in Substituted Spinels

Study of the Dielectric Variation Due To Phase Transformation in Substituted Spinels

... dried in a muffle furnace at 200 o C for 2 hours. These were mixed in stoichiometric proportion, ground and calcined in steps of 600 o C, 800 o C and 1000 o C for eight hours each .To obtain homogeneity, these mixtures ...

10

Multistate transition modeling: An application using hypertension data

Multistate transition modeling: An application using hypertension data

... transition intensities and state occupation probabilities) can be calculated for complete data and also using estimators obtained from censored data when complete data is not ...

7

FORMULAE AND TABLES FOR CALCULATING LINKAGE INTENSITIES

FORMULAE AND TABLES FOR CALCULATING LINKAGE INTENSITIES

... Linkage intensities calculated from F2 coupling data are more reliable as measured by the probable error, than from F, repulsion data, the relative reliability depending[r] ...

18

Show all 10000 documents...

Related subjects