• No results found

measurement devices

Macroscopic superpositions require tremendous measurement devices

Macroscopic superpositions require tremendous measurement devices

... We consider fundamental limits on the de- tectable size of macroscopic quantum super- positions. We argue that a full quantum me- chanical treatment of system plus measure- ment device is required, and that a (classical) ...

19

The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

... two measurement devices are small, but it can be conservative when the relative bias square value is unreasonably large and when the coverage prob- ability is large ...

12

Siphons as furrow irrigation measurement devices

Siphons as furrow irrigation measurement devices

... states “manometers measure pressure differences using a column of fluid”, for which water was the fluid for this project. The manometers were 12.5 mm ID clear plastic tubing and were used to measure the entrance losses, ...

87

Anaesthesia workload measurement devices: qualitative systematic review

Anaesthesia workload measurement devices: qualitative systematic review

... Vigilance (response latency) and physiological data are objective methods that require more technical involvement, considerable time for investigator, and are moderately expensive. Physiological measurement ...

18

Extended Cases of Laboratory Generated Gravitomagnetic Field Measurement Devices

Extended Cases of Laboratory Generated Gravitomagnetic Field Measurement Devices

... Due to the large magnetic fields developed in SMES devices Lorentz forces are a major design constraint. In this appendix, we explore how nanowires based on weaving together the nanotube fibers described in ...

20

Ring Laser for Angle Measurement Devices 

Ring Laser for Angle Measurement Devices 

... $QJOH PHDVXUHPHQW PHDQV DUH RQH RI WKH DGYDQFHG GLUHFWLRQV IRU WKH DSSOLFDWLRQ RI JDV ULQJ ODVHUV 7KH UHTXLUHPHQWV RI ULQJ ODVHUV XVHG LQ DQJOH PHDVXUHPHQW GHYLFHV DUH GLIIHUHQWLQPDQ\UHV[r] ...

9

Fiber Optic As Electric Current Sensor

Fiber Optic As Electric Current Sensor

... There are many different variations of current measurement devices available nowadays. Generally, they can be classified into two major categories. The first category is the direct electric current ...

24

Novel fusion approaches for the dissolved gas analysis of insulating oil

Novel fusion approaches for the dissolved gas analysis of insulating oil

... In this architecture, raw data received from sensors or measurement devices are combined in an appropriate method to achieve more reliable and accurate data. The fused data are used for[r] ...

12

Influence of Temperature on the Measuring Accuracy of Devices Based on Surface  Plasmon Resonance Phenomenon

Influence of Temperature on the Measuring Accuracy of Devices Based on Surface Plasmon Resonance Phenomenon

... Diagnostic devices that operate using the SPR phenomenon possess high sensitivity to low concentrations of studied sub- stances, which enables to use them as precise analytical tools in laboratory inves- tigations ...

10

Results from Running an Experiment as a Service Platform for Mobile Broadband Networks in Europe

Results from Running an Experiment as a Service Platform for Mobile Broadband Networks in Europe

... MONROE is a Europe-wide experiment oriented network counting on more than 200 custom measurement devices (or nodes ), designed to enable collection and analysis of the characteristics of[r] ...

36

Structures in Real Theory Application: A Study in Feasible Epistemology

Structures in Real Theory Application: A Study in Feasible Epistemology

... Thus, the overall picture is that of a theoretical model of the phenomenon, models of the measurement devices and their data reduction, and information transmission models that connect t[r] ...

293

Studies on the Application of R-SFCL in the VSC-HVDC Transmission System

Studies on the Application of R-SFCL in the VSC-HVDC Transmission System

... current measurement devices ,one current device is in series with transmission line going towards controlled voltage source and another current measurement device connected with RMS converter after ...

8

Coherent detection of metal-metal terahertz quantum cascade lasers with improved emission characteristics

Coherent detection of metal-metal terahertz quantum cascade lasers with improved emission characteristics

... several devices for which we have performed this procedure, we see variation in the far-field patterns ...the devices, this is also associated with a change in the far-field ...

6

Observation of interdot coupling phenomena in nanocrystalline silicon point contact structures

Observation of interdot coupling phenomena in nanocrystalline silicon point contact structures

... the measurement results in two devices, Device 1 which was oxidised at 750 C for 60 min and annealed for 5 min at 1000 C, and Device 2 which was only oxidised for 30 min at 750 ...

5

Development of a Measurement Software for the Characterization of WORM Devices for Novel Memory Storage Applications

Development of a Measurement Software for the Characterization of WORM Devices for Novel Memory Storage Applications

... stopped and the last applied voltage is defined as the ON switching voltage. Also, this function allows optimizing the number of pulses and the duration. The core of this function, in a typical C# namespace, should ...

13

Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension

Validation of four automatic devices for self-measurement of blood pressure according to the international protocol of the European Society of Hypertension

... The Omron M3 (HEM-7200-E) device records brachial BP using the oscillometric method with a pressure range of 0–299 mmHg and pulse rate range of 40–180 beats/minute. Inflation is performed using a fuzzy-logic electric ...

9

Development of Paper-Based Analytical Devices for Minimizing the Viscosity Effect in Human Saliva

Development of Paper-Based Analytical Devices for Minimizing the Viscosity Effect in Human Saliva

... process was divided into three parts. First, pH values of artificial saliva were adjusted to obtain a range of pH values with 1 M NaOH and 1 M HCl. The viscosities of these samples ranged between 1.54–5.10 mPa∙s and were ...

11

Hardware design optimization for human motion tracking systems

Hardware design optimization for human motion tracking systems

... single measurement of a random signal. Any single measurement could be the mean (µ ), one sigma (σ ) or many sigmas away from the expected value of the signal ...single measurement is taken per ...

190

Energy Consumption Anatomy of 802.11 Devices and its Implication on Modeling and Design

Energy Consumption Anatomy of 802.11 Devices and its Implication on Modeling and Design

... thorough measurement analysis of the power consumption of 802.11 devices that, in contrast to previous works, provides a detailed anatomy of the per-packet consumption and characterizes the total ...

12

1.
													Wireless sensor network based real time monitoring system for electrical power distribution network

1. Wireless sensor network based real time monitoring system for electrical power distribution network

... The wireless sensor nodes are the onsite devices which does the measurement of electrical quantities like voltage, current etc at the distribution point. As the electrical quantities to be measured are of ...

6

Show all 10000 documents...

Related subjects