• No results found

Mini-implant

Impact of mini-implant length on stability at the initial healing period: a controlled clinical study

Impact of mini-implant length on stability at the initial healing period: a controlled clinical study

... the mini-implants superimposed with the anticipated path of the incisive canal give reason to pre- sume that the canal was hit in some ...affect mini-implant ...a mini-implant ...

7

A simple three-dimensional stent for proper placement of mini-implant

A simple three-dimensional stent for proper placement of mini-implant

... A number of stents have been proposed by the several clinicians. The stent described by Jae-Jung Yua et al. [17] requires the use of cone beam computed tomography and hence very expensive. It also carries risk of ...

12

Stress distribution patterns at mini-implant site during retraction and intrusion—a three-dimensional finite element study

Stress distribution patterns at mini-implant site during retraction and intrusion—a three-dimensional finite element study

... greatest implant-bone interface surface area of ...when mini-implants are used for skeletal anchorage, it is the cortical bone which provides ...the mini-implant rather than the whole ...the ...

11

Effective En-Masse retraction of maxillary dentition with tuberosity mini-implant anchorage: A finite element analysis

Effective En-Masse retraction of maxillary dentition with tuberosity mini-implant anchorage: A finite element analysis

... titanium mini-implant systems activated with different load ...200 mini-implants (102 Abso Anchor and 98 Dual Top) were placed in the mandible of eight Göttinger ...the implant and the bone ...

100

The efficacy of maxillary protraction protocols with the micro-implant-assisted rapid palatal expander (MARPE) and the novel N2 mini-implant—a finite element study

The efficacy of maxillary protraction protocols with the micro-implant-assisted rapid palatal expander (MARPE) and the novel N2 mini-implant—a finite element study

... N2 mini- implant (3-mm diameter, 2-mm length, tapered shape), it is believed that the short length of the implant reduces the risk of damaging anatomic structures during placement and therefore does ...

14

Gender and growth variation in palatal bone thickness and density for mini-implant placement

Gender and growth variation in palatal bone thickness and density for mini-implant placement

... the mini-implant placement ...Palatal mini-implants have shown ex- cellent ...of mini-implants are stable, when they are inserted in the anterior region of the palate ...of ...

10

Identification of ideal site of placing mini-implant in para-median palate: a cone beam computerized tomography study

Identification of ideal site of placing mini-implant in para-median palate: a cone beam computerized tomography study

... an implant site is because it is easily approachable, relatively safe, increased blood flow leading to less inflammation with good bone ...as implant site, the paramedian area is The various biomechanics ...

5

Comparison of patient satisfaction with mini-implant versus standard diameter implant overdentures: a systematic review and meta-analysis of randomized controlled trials

Comparison of patient satisfaction with mini-implant versus standard diameter implant overdentures: a systematic review and meta-analysis of randomized controlled trials

... of mini-implants, various randomized controlled trials have been tried on mini- implant-supported overdentures for edentulous ...comparing mini-implants with standard diameter implants were ...

6

Evaluation of orthodontic mini-implant placement: a CBCT study

Evaluation of orthodontic mini-implant placement: a CBCT study

... for mini-implant placement, was done after preparatory ortho- dontic treatment unlike other studies [9-12] where CBCT scan was done prior to the ...the mini-implant positioning according to ...

9

Clinical evaluation of center of resistance of maxillary anterior  teeth during en masse retraction with mini implant anchorage

Clinical evaluation of center of resistance of maxillary anterior teeth during en masse retraction with mini implant anchorage

... with mini implants placed between maxillary first molar and second premolar as anchorage, assuming that the force will act through the Center of re retraction and post retraction lateral cephalograms of each ...

6

Biocompatibility and biodegradation studies of a commercial zinc alloy for temporary mini-implant applications

Biocompatibility and biodegradation studies of a commercial zinc alloy for temporary mini-implant applications

... The study suggests that the zinc alloy exhibited similar biocompatibility to pure zinc. It was interesting to see that the biodegradation resistance of the zinc alloy, which has been used for galvanization for its ...

11

Comparative Assessment of Three Microimplant Assisted Biomechanical Strategies for the Simultaneous Intrusion and Retraction of Anterior Teeth in Relation to Alveolar Bone Stress and Change in Incisor Inclinations – A 3D Finite Element Analysis Study

Comparative Assessment of Three Microimplant Assisted Biomechanical Strategies for the Simultaneous Intrusion and Retraction of Anterior Teeth in Relation to Alveolar Bone Stress and Change in Incisor Inclinations – A 3D Finite Element Analysis Study

... of implant placement sites for cases in which en-masse anterior retraction is done along with ...three mini-implant placement sites compared were – S1- Midline micro implant between the ...

11

Micro-Implants: Innovative Anchorage Concepts in Orthodontics

Micro-Implants: Innovative Anchorage Concepts in Orthodontics

... orthodontic mini- implant is not designed to ...complicate implant removal and is therefore not ...reduced implant success are improper implant site selection, overheating of the bone ...

6

Application of the 2-piece orthodontic C-implant for provisional restoration with laser welded customized coping: a case report

Application of the 2-piece orthodontic C-implant for provisional restoration with laser welded customized coping: a case report

... This article presents the application of laser welding technique to fabricate an orthodontic mini-implant provisional restoration in missing area after limited orthodontic treatment. A 15-year-old boy case ...

6

Evaluation of inter-radicular spaces and cortical bone thickness at common orthodontic mini-screw implant placement sites using cone beam computed tomography

Evaluation of inter-radicular spaces and cortical bone thickness at common orthodontic mini-screw implant placement sites using cone beam computed tomography

... The cortical bone thickness in the mandibular buccal region was significantly greater than maxillary buccal region in our study. The results of this study in terms of cortical bone thickness for ...

6

Bone Mapping of the Mandibular Buccal Shelf: A CBCT study

Bone Mapping of the Mandibular Buccal Shelf: A CBCT study

... In a randomized block study design (left and right MSI interradicular sites in the same arch in a patient). All the MSIs were then randomly allocated by using split mouth system into two groups such that MSI placement ...

137

Bone Mapping for Mini-Implant Placement with Various Facial Growth Patterns using Three Dimensional Volumetric Tomography

Click here to download PDF version of the article !

... The 3-DVT images can provide accurate measurements of small areas in bone to determine the best anchors placement areas which moreover offers significant protection against the two major problems of ...

6

Mechanical Consideration of Mini-Implants - A Short Review

Mechanical Consideration of Mini-Implants - A Short Review

... Contemporarily, mini-implants have a multitude of indications in orthodontic practice with a wide range of size and design ...options. Mini-implant anchorage is reported to be used in many cases, ...

5

Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study

Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study

... the implant in compari- son to off-axial loading where stresses were more pro- nounced in the area of load ...single-unit implant restoration because the restoration itself is usually wider than the ...

9

An ectodermal dysplasia patient treated with a small diameter implant supporting a single crown

An ectodermal dysplasia patient treated with a small diameter implant supporting a single crown

... satisfaction with conventional dentures and mini implant anchored overdentures. Rev Med Chir Soc Med Nat Iasi. 2012;116(1):310–316. 31. Güler N, Cildir S, Iseri U, Sandalli N, Dilek O. Hypohidrotic ...

7

Show all 3337 documents...