Shape-controlled Synthesis of Cu2O Microstructures at Glassy Carbon Electrode by Electrochemical Method for Non-enzymatic Glucose Sensor

Shape-controlled Synthesis of Cu2O Microstructures at Glassy Carbon Electrode by Electrochemical Method for Non-enzymatic Glucose Sensor

... has some critical flaws such as low stability of the immobilized enzyme, complicated fabrication process and unrepeatability [3-7]. As a result, many efforts have been made to fabricate novel non- enzymatic ...

8

A Non-Enzymatic Glucose Sensor Based on Pd-Fe/Ti Nanocomposites

A Non-Enzymatic Glucose Sensor Based on Pd-Fe/Ti Nanocomposites

... detect glucose is the interference (for instance, AA, UA and ...that glucose concentration (3 ~ 8 mM) is higher than those of ascorbic acid (AA, ...this sensor, an experiment was carried out by ...

11

A Novel Non-Enzymatic Glucose Sensor Based on CuO-Graphene Nanocomposites

A Novel Non-Enzymatic Glucose Sensor Based on CuO-Graphene Nanocomposites

... construct non-enzymatic sensors, such as oxygen sensors [24, 25] and methanol sensors [26, ...measuring glucose with good performance ...of glucose. Based on this, a ...

8

Cuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry (DPV) and Other Voltammetry Methods and Comparing to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution

Cuprous Oxide Thin Film Non-Enzymatic Glucose Sensor Using Differential Pulse Voltammetry (DPV) and Other Voltammetry Methods and Comparing to Different Thin Film Electrodes on the Detection of Glucose in an Alkaline Solution

... of glucose can be detected ...for glucose oxidation reaction in non-enzymatic glucose sensor development [6, 7, ...complex sensor preparation procedures and unpracticality ...

13

Novel One Pot Synthesis of Alkaline-reduced Iron Oxide/graphene Nanocomposites for Amperometric Non- enzymatic Glucose Sensor

Novel One Pot Synthesis of Alkaline-reduced Iron Oxide/graphene Nanocomposites for Amperometric Non- enzymatic Glucose Sensor

... pure glucose stock solution was introduced in the above solution, followed by the addition diluted glucose ranged from ...of glucose in the initial blood samples was then ...detecting glucose ...

14

Non Enzymatic Glucose Sensor Based on the Novel Flower Like Morphology of Nickel Oxide

Non Enzymatic Glucose Sensor Based on the Novel Flower Like Morphology of Nickel Oxide

... The electro catalytic activity of NiO flower-like nanos- tructured electrode taword the oxidation of glucose was studied by cyclic voltammetry (CV). Figure 3 shows the CV response of the bare gold electrode and ...

5

Facile Synthesis of Bimetallic PtxCu1-x Nanostrands and Their Application in Non-Enzymatic Glucose Sensor

Facile Synthesis of Bimetallic PtxCu1-x Nanostrands and Their Application in Non-Enzymatic Glucose Sensor

... to glucose oxidation was sensitive and ...versus glucose concentrations. It has a linear glucose concentration in the range of ...our sensor is superior to those reported in other literatures ...

14

Mesoporous Nickel Oxide (NiO) Nanopetals for Ultrasensitive Glucose Sensing

Mesoporous Nickel Oxide (NiO) Nanopetals for Ultrasensitive Glucose Sensing

... excellent glucose sensing behavior with improved sensitivity has been achieved by using an elec- trode with hydrothermally grown highly dense, aligned NiO nanostructures (NSs), with high surface to volume ...

7

Synthesis of Cuprous Oxide (Cu2O) Nanoparticles/Graphene Composite with an Excellent Electrocatalytic Activity Towards Glucose

Synthesis of Cuprous Oxide (Cu2O) Nanoparticles/Graphene Composite with an Excellent Electrocatalytic Activity Towards Glucose

... gas sensor, Li ion battery, gas sensor, field-effect transistors and biosensors for a long time ...the non-enzymatic detection of glucose [31, ...a non- enzymatic ...

11

A New Non-Enzymatic Amperometric Sensor Based on Nickel Decorated ZIF-8 Derived Carbon Nanoframe for the Glucose Determination in Blood Samples

A New Non-Enzymatic Amperometric Sensor Based on Nickel Decorated ZIF-8 Derived Carbon Nanoframe for the Glucose Determination in Blood Samples

... of glucose detection, Ni/NPC/GCE was immersed in ...varying glucose concentration at the optimal potential of ...varying glucose concentration infusion shows high performance with quick responses ...

15

Highly sensitive, non-enzymatic and precious metal-free electrochemical glucose sensor based on a Ni–Cu/TiO2 modified glassy carbon electrode

Highly sensitive, non-enzymatic and precious metal-free electrochemical glucose sensor based on a Ni–Cu/TiO2 modified glassy carbon electrode

... of glucose at a fixed set potential ...of glucose on modified electrode increases linearly with glucose concentration up to 6 mM (Fig S-3 of the Supplementary ...the sensor was found to be 30 ...

12

Facile two-step Electrodeposition Synthesis of CuO Nanowires for Ultrasensitive Non-Enzymatic Sensing of Glucose

Facile two-step Electrodeposition Synthesis of CuO Nanowires for Ultrasensitive Non-Enzymatic Sensing of Glucose

... In order to obtain the non-enzymatic Glc sensor with good sensitivity and wide linear detection range, we initially optimized electrodeposition time of Cu. Fig. 4A shows the effect of Cu ...

13

Ultrasensitive and selective non-enzymatic glucose detection based on pt electrode modified by carbon nanotubes@ graphene oxide/ nickel hydroxide-Nafion hybrid composite in alkaline media

Ultrasensitive and selective non-enzymatic glucose detection based on pt electrode modified by carbon nanotubes@ graphene oxide/ nickel hydroxide-Nafion hybrid composite in alkaline media

... the glucose sensor at +0.450 V on successive step changes of glucose concentration to a continuous stirring 10 mL NaOH ...the sensor is ...

10

Facile Preparation of PtNPs/BSA-RGO Nanostructure for Non- Enzymatic Glucose Electrochemical Sensing

Facile Preparation of PtNPs/BSA-RGO Nanostructure for Non- Enzymatic Glucose Electrochemical Sensing

... for glucose sensing [10, 17, 18, 20, ...reliable non-enzymatic electrochemical glucose sensor, which is based on mesoporous Au/Pt nanodendrites prepared by a facile ...for ...

10

Non-Enzymatic Glucose Sensors for Sensitive Amperometric Detection Based on Simple Method of Nickel Nanoparticles Decorated on Magnetite Carbon Nanotubes Modified Glassy Carbon Electrode

Non-Enzymatic Glucose Sensors for Sensitive Amperometric Detection Based on Simple Method of Nickel Nanoparticles Decorated on Magnetite Carbon Nanotubes Modified Glassy Carbon Electrode

... based sensor is an attractive alternative technique to solve the disadvantages of enzymatic ...of glucose is achieved via directly electrochemical oxidation of glucose at the surface of ...

15

Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation

Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation

... surround enzymatic systems in all fields of science also hinder the development and application of enzymatic glucose ...problems, enzymatic glucose sensors remain commercially ...

56

Carbon Nanotube (CNT) Biosensor For Diabetes Disease

Carbon Nanotube (CNT) Biosensor For Diabetes Disease

... of glucose transport in the body ...time glucose sensing in blood and body fluids at molecular and cellular levels is vital for diagnosis of insulin shortage and hyperglycemia with regard to the role of ...

6

Ultrasensitive and selective non-enzymatic electrochemical glucose sensor based on hybrid material of graphene nanosheets/graphene nanoribbons/nickel nanoparticle

Ultrasensitive and selective non-enzymatic electrochemical glucose sensor based on hybrid material of graphene nanosheets/graphene nanoribbons/nickel nanoparticle

... of glucose and exhibited excellent performances for the amperometric determination of glucose with rapid response, low detection limit, high sensitivity and selectivity, wide linear range and good long-term ...

8

Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel

Non-enzymatic Sensing of Glucose Using Glassy Carbon Electrode Modified with Organometallic Complex of Nickel

... toward glucose oxidation in alkaline ...current, glucose was oxidized on the modified electrode surface via an electrocatalytic ...that glucose oxidation current response increases with increasing ...

10

p Coumaric acid regulates blood glucose and antioxidant levels in streptozotocin induced diabetic rats

p Coumaric acid regulates blood glucose and antioxidant levels in streptozotocin induced diabetic rats

... Streptozotocin (STZ) is a broad spectrum antibiotic and alkylating genotoxic agent which possesses antibacterial, tumoricidal, carcinogenic and diabetogenic properties [9;10]. Induction of experimental diabetes in rats ...

9

Show all 10000 documents...