• No results found

Non Invasive assessment

Non Invasive Assessment of Fibrosis of Liver using Fibroscan in Patients with Diabetes Mellitus

Non Invasive Assessment of Fibrosis of Liver using Fibroscan in Patients with Diabetes Mellitus

... Certified that this dissertation in “NON INVASIVE ASSESSMENT OF FIBROSIS OF LIVER USING FIBROSCAN IN PATIENTS WITH DIABETES MELLITUS” is the bonafide dissertation done by Dr. R. Nandhini devi and ...

98

Validation of "Signs of Inflammation in Children that Kill" (SICK) score for immediate non-invasive assessment of severity of illness

Validation of "Signs of Inflammation in Children that Kill" (SICK) score for immediate non-invasive assessment of severity of illness

... Validation of "Signs of Inflammation in Children that Kill" (SICK) score for immediate non-invasive assessment of severity of illness.. Manoj A Gupta 1 , Anjan Chakrabarty 2 , [r] ...

6

Non-invasive assessment of vascular alteration using ultrasound

Non-invasive assessment of vascular alteration using ultrasound

... the assessment of arterial properties since it allows good spatial resolution when using ...terial assessment, various parameters can be measured and carotid intima-media thickness (cIMT) has been sug- ...

6

The non-invasive assessment of the ischaemic limb, with particular reference to thermography.

The non-invasive assessment of the ischaemic limb, with particular reference to thermography.

... the assessment of trauma cases in the emergency department, and low Tcp02 values have been shown to predict hypovolaemia even in the presence of normal blood pressure (Waxman et ...

328

A 3D machine vision method for non invasive assessment of respiratory function

A 3D machine vision method for non invasive assessment of respiratory function

... appropriate assessment tool exists, even though continuous monitoring could provide early warning of disease, that repeating conventional tests does not offer (and that simple tests such as respiratory rate might ...

34

Non Invasive assessment of Coronary Flow Velocity reserve with Transthoracic Colour Doppler Echocardiography to predict significant Left Anterior Descending Coronary Artery Stenosis.

Non Invasive assessment of Coronary Flow Velocity reserve with Transthoracic Colour Doppler Echocardiography to predict significant Left Anterior Descending Coronary Artery Stenosis.

... the assessment of CFVR were obtained 59 of 75 patients who were submitted for TTCDE to estmate CFR and those patientsfor whom LAD could not be visualized, were excluded for statistical ...

58

Non-invasive assessment of the reproductive cycle in free-ranging female African elephants (Loxodonta africana) treated with a gonadotropin-releasing hormone (GnRH) vaccine for inducing anoestrus

Non-invasive assessment of the reproductive cycle in free-ranging female African elephants (Loxodonta africana) treated with a gonadotropin-releasing hormone (GnRH) vaccine for inducing anoestrus

... monitored non-invasively using an enzyme immunoassay detecting faecal 5alpha-reduced pregnanes (faecal progestagen metabolites, FPM) on a private game reserve in South ...

10

Comparison of ELF, FibroTest and FibroScan for the non-invasive assessment of liver fibrosis

Comparison of ELF, FibroTest and FibroScan for the non-invasive assessment of liver fibrosis

... Statistical analysis was performed using BiAS for Windows (version 9.04, epsilon 2009, Frankfurt, Ger- many). Correlations were assessed by Spearmans correla- tion coefficient. The diagnostic performance of ELF, ...

8

Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement

Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement

... We therefore aimed to develop a simple and non-invasive method of evaluating arterial stiffness using oscillometric measurements of blood pressure. When blood pressure is measured by cuff oscillometry, ...

12

Non Invasive Assessment  of Coronary Microcirculation  in Heart Transplantation

Non Invasive Assessment of Coronary Microcirculation in Heart Transplantation

... and invasive coronary flow measures in heart transplant patients; PET demonstrated high diagnostic performance for detecting epicardial intimal disease in ...PET assessment for any one abnormal PET cMFR, ...

16

Exhaled breath condensate cysteinyl leukotrienes and airway remodeling in childhood asthma: a pilot study

Exhaled breath condensate cysteinyl leukotrienes and airway remodeling in childhood asthma: a pilot study

... of non-invasive tools to meas- ure inflammation (EBC, induced sputum, exhaled breath), non-invasive assessment monitoring of remode- ling is much more ...a non-invasive ...

7

Reservoir assessment using non-invasive geophysical techniques

Reservoir assessment using non-invasive geophysical techniques

... comprehensive non-invasive assessment to be used as common practice by local authorities and environment agencies whereby remedial action could be recommended to protect assets and ...

14

Quantitative motor assessment of muscular weakness in myasthenia gravis: a pilot study

Quantitative motor assessment of muscular weakness in myasthenia gravis: a pilot study

... subjective assessment and therefore inherent imprecision as well as the lack of quan- tification ...objective assessment of muscular weakness in patients with ...

7

Non-Invasive Breast Cancer Assessment Using Magnetic Induction Spectroscopy Technique

Non-Invasive Breast Cancer Assessment Using Magnetic Induction Spectroscopy Technique

... Traditional breast cancer imaging modalities include mammography, breast ultrasound and magnetic resonance imaging (MRI) have some shortcomings when they come to sensitivity and specificity [4]. These imaging modalities ...

7

Factors affecting carotid intimal medial thickness in patients with rheumatoid arthritis, an analytical cross-sectional study

Factors affecting carotid intimal medial thickness in patients with rheumatoid arthritis, an analytical cross-sectional study

... IMT assessment as a non-invasive imaging test is quite widely used especially among RA patients, the clinical applications of using such knowledge is scarce, hence study was conducted to compare the ...

6

In vivo quantification of the functional characteristics of the rearfoot complex

In vivo quantification of the functional characteristics of the rearfoot complex

... A non invasive in vivo kinematic assessment was conducted to determine the relative rotations at the ankle/sub talar complex, the mid tarsal joint and the rearfoot complex, during weight[r] ...

419

Comparison of ultrasonographic versus infrared pupillary assessment

Comparison of ultrasonographic versus infrared pupillary assessment

... The small patient population of this study is its major limitation. The greater limitation for UPA is the experi- ence of the operator, for the reliability and accuracy of UPA are directly related to operator skills. ...

10

2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis

2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis

... a non-invasive tool which uses the usual 2D US probe, yet with produc- tion of a focused acoustic beam to generate shear wave within the liver with the degree of liver fibrosis reflected upon the speed of ...

9

Evaluation of sonosalpingography as a screening test for tubal patency in comparison with hysterosalpingography

Evaluation of sonosalpingography as a screening test for tubal patency in comparison with hysterosalpingography

... the assessment of tubal patency, which is important in diagnosing tubal causes of infertility, was successful in 79% of woman when saline was used and in 92% of patients when a contrast agent was ...

94

Non-invasive biomarkers and pulmonary function in smokers

Non-invasive biomarkers and pulmonary function in smokers

... Abstract: Limited information exists regarding measurement, reproducibility and interrelationships of non-invasive biomarkers in smokers. We compared exhaled breath condensate (EBC) leukotriene B 4 (LTB 4 ) ...

14

Show all 10000 documents...

Related subjects