• No results found

Nuclear track

Recent applications of nuclear track emulsion

Recent applications of nuclear track emulsion

... Application of the nuclear track emulsion technique (NTE) in ra- dioactivity and nuclear fission studies is discussed. It is suggested to use a HSP-1000 automated microscope for searching for a ...

6

Improvement of charge resolution for trans-iron nuclei (Z ≥ 30) in CR-39 plastic nuclear track detectors using trajectory tracing technique

Improvement of charge resolution for trans-iron nuclei (Z ≥ 30) in CR-39 plastic nuclear track detectors using trajectory tracing technique

... plastic nuclear track detec- tor (PNTD) using the trajectory tracing technique with av- eraging the signals of nuclear tracks for each ion was stud- ied as a part of systematic project to measure the ...

6

A Novel Detection Technique for Nuclear Radiations: Solid State Nuclear Track Detector, CR 39: A Review

A Novel Detection Technique for Nuclear Radiations: Solid State Nuclear Track Detector, CR 39: A Review

... CR-39 Nuclear Track Detectors have been aligned for identification of alpha-particles and protons in a high neutron transition ...State Nuclear Track ...

5

Optimization of chemical etching parameters of strippable and non strippable solid state nuclear track detectors (SSNTD) LR 115 type II

Optimization of chemical etching parameters of strippable and non strippable solid state nuclear track detectors (SSNTD) LR 115 type II

... State Nuclear Track Detectors (SSNTD) LR 115 type II have been first ...the track density of the strippable films has been ...of track density obtained are respectively 120 minutes and ...

5

Measurement of Uranium Concentration in the Soil Samples by Using Solid State Nuclear Track Detectors (SSNTDs)

Measurement of Uranium Concentration in the Soil Samples by Using Solid State Nuclear Track Detectors (SSNTDs)

... CR-39 (Polyallyl diglycol carbonate) is a commonly used solid state nuclear track detector (SSNTD). CR-39 detectors are widely used in different branches of sciences such as nuclear physics, radon ...

6

Progress of analysis of dissociation of 10C, 10B and 12C nuclei in nuclear track emulsion

Progress of analysis of dissociation of 10C, 10B and 12C nuclei in nuclear track emulsion

... The cluster structure of light nuclei including radioactive ones is under study by means of 0.5 mm pellicles of nuclear track emulsion (NTE) exposed longwise to primary and secondary beams of relativistic ...

6

Measurement of Radon Exhalation Rate in Some Building Materials Using Nuclear Track Detectors

Measurement of Radon Exhalation Rate in Some Building Materials Using Nuclear Track Detectors

... state nuclear track detector. Solid state nuclear track detectors have become an important tool in every inves- tigation of the radon levels in the surrounding ...

8

Microstructural Investigation of PM 355 Nuclear Track Detector Subjected to Low Dose Gamma Irradiation: A Positron Annihilation Lifetime Study

Microstructural Investigation of PM 355 Nuclear Track Detector Subjected to Low Dose Gamma Irradiation: A Positron Annihilation Lifetime Study

... solid-state nuclear track detectors (SSNTDs), it would be meaning- ful to study the modification on their properties due to ...Solid-state nuclear track detectors have found a variety of ...

8

Analysis of Nuclear Track Parameters of CN 85 Detector Irradiated to Thermal Neutrons by Using MATLAB Program

Analysis of Nuclear Track Parameters of CN 85 Detector Irradiated to Thermal Neutrons by Using MATLAB Program

... for track recognition and track parameters measurements from images of the solid state nuclear track detectors type ...state nuclear track ...solid-state nuclear ...

8

Determination of Alpha Rates Emitted from Animal Bones Using CN-85 Nuclear Track Detector

Determination of Alpha Rates Emitted from Animal Bones Using CN-85 Nuclear Track Detector

... solid-state nuclear track detector is based on the fact that a heavy charged particle will cause extensive ionization of the material when it passes through a medium ...of nuclear track ...

5

Mapping of Radon (220Rn and 222Rn) Concentration Distribution in a  Microclimate Condition Cellar Using Nuclear Track Methodology

Mapping of Radon (220Rn and 222Rn) Concentration Distribution in a Microclimate Condition Cellar Using Nuclear Track Methodology

... Because of the radon concentration, data obtained are the basis for calculation of the dose and risk of cancer and the public health. Therefore, the efforts of the analysis and measurements of radon should be exhaustive ...

10

A Review Article on the Study of Radon and Thoron Concentration using Solid State Nuclear Track Detector

A Review Article on the Study of Radon and Thoron Concentration using Solid State Nuclear Track Detector

... P C Deka et al., [2009], monitored indoor radon and thoron concentration levels in the territories of Nalbari, Assam, India. The levels of indoor radon and thoron were studied by utilizing the LR-115 (type II) ...

5

Nuclear Track Detectors for Relativistic Nuclear  Fragmentation Studies: Comparison with Other  Competitive Techniques

Nuclear Track Detectors for Relativistic Nuclear Fragmentation Studies: Comparison with Other Competitive Techniques

... the track measure- ments at the PINSTECH laboratory were done ...of track forming ...automatic nuclear track scan- ...of nuclear fragmentation were made with observa- tions of change in ...

11

Radon Levels in Surface Water Samples from Manzala Lake East Nile Delta, Egypt using Nuclear Track Detectors

Radon Levels in Surface Water Samples from Manzala Lake East Nile Delta, Egypt using Nuclear Track Detectors

... [13] Barooah D., Phukan S., Baruah R. Study of radon exhalation rates using LR-115 (II) nuclear track detectors in coal mining area of the foothills of Mokokchung District, Nagaland. Indian Journal of Pure ...

7

Studying Different Etching Methods Using CR 39 Nuclear Track Detector

Studying Different Etching Methods Using CR 39 Nuclear Track Detector

... The track density when etching with water bath is increased between the etching times (60 - 150 ...the track density would appears at etching time range (20 - 30 ...the track density would appears at ...

9

Measurement of Indoor Radon Concentration in Bahraich and Barabanki District of Eastern U P  using LR 115 Type II Plastic Track Detector (SSNTDS)

Measurement of Indoor Radon Concentration in Bahraich and Barabanki District of Eastern U P using LR 115 Type II Plastic Track Detector (SSNTDS)

... plastic track detectors commonly known as solid state nuclear track detectors (SSNTDs) used to measure the radon ...state nuclear track detector was employed for measuring the Potential ...

10

Radon Concentration Measurements in  Gattar Uranium Prospect, Northern  Eastern Desert, Egypt

Radon Concentration Measurements in Gattar Uranium Prospect, Northern Eastern Desert, Egypt

... The concentration of Radon in mines varies tremendously according to the country rock, type of mineralization and area. Ventilation is also an impor- tant factor. The absence of ventilation in mines tends to allow a ...

11

Magnetic monopole search with the MoEDAL test trapping detector

Magnetic monopole search with the MoEDAL test trapping detector

... techniques: nuclear- track detectors for high-ionisation signatures and other highly ionising avatars of new physics, and trapping volumes for direct magnetic charge measurements with a super- conducting ...

8

Measure the Bulk Etch Rate Using the Time Diameter Method

Measure the Bulk Etch Rate Using the Time Diameter Method

... [10] Balestra, S., Cozzi, M., Giacomelli, G., Giacomelli, R., Giorgini, M., Kumar, A., Mandrioli, G., Manzoor, S., Margiot- ta, A.R., Medinaceli, E., Partizii, L., Popa, V., Qureshi, I.E., Rana, M.A., Sirri, G., Spurio, ...

6

222Rn and 220Rn Concentrations Measured in Bottled Sweet Drinks and Their Residual Gases and Resulting Radiation Doses to the Consumers

222Rn and 220Rn Concentrations Measured in Bottled Sweet Drinks and Their Residual Gases and Resulting Radiation Doses to the Consumers

... state nuclear track detectors (SSNTDs) of radius q=2cm in hermetically sealed (using glue and a cellophane tape) cylindrical plastic containers for one month (30 days) ...

8

Show all 10000 documents...

Related subjects