• No results found

Optical Coherence Tomography Forward-Imaging Probe

OPTICAL COHERENCE TOMOGRAPHY FOR RETINAL IMAGING

OPTICAL COHERENCE TOMOGRAPHY FOR RETINAL IMAGING

... aberrations in the eye limit the useful diameter of the collimated beam, with an optimum beam diameter of approximately 1.5 to 2 mm. 18 2.3.2 Retinal illumination A well-balanced retinal illumination is vital for a good ...

132

Development of Optical Coherence Tomography Using KTN Optical Probe

Development of Optical Coherence Tomography Using KTN Optical Probe

... the optical axis in KTN optical scanner. The telecentric optical system is useful for measurement of close object such as biological tissue using ...KTN probe, the gradient index (GRIN) lens ...

7

Ex Vivo Optical Coherence Tomography Imaging of

Collector Channels with a Scanning Endoscopic Probe

Ex Vivo Optical Coherence Tomography Imaging of Collector Channels with a Scanning Endoscopic Probe

... endoscopic probe to determine the locations of CCs for the bypass stent implanta- tion, as illustrated in Figure ...proposed probe passes through the corneal incision for implantation and is advanced across ...

5

Combining Optical Coherence Tomography with Fluorescence Imaging

Combining Optical Coherence Tomography with Fluorescence Imaging

... errors. Optical imaging technologies can provide real-time imaging of human tissues in vivo with resolutions approaching that of histopathology and have the potential to reveal the biochemical and/or ...

27

Optical-coherence tomography, extension to imaging of low coherence interferometry

Optical-coherence tomography, extension to imaging of low coherence interferometry

... 3. THE EXPERIMENTAL CONFIGURATION The optical configuration 5 uses two single mode directional couplers with a superluminiscent diode as the source. The scanning procedure is similar to that used in any confocal ...

7

Optical coherence tomography for retinal imaging in multiple sclerosis

Optical coherence tomography for retinal imaging in multiple sclerosis

... Dovepress Optical coherence tomography in multiple sclerosis dependency on the acute inflammatory status of the optic nerve. 42,44 It was also reported that macular microcysts are not exclusive to ...

10

Choroidal imaging by spectral domain-optical coherence tomography

Choroidal imaging by spectral domain-optical coherence tomography

... addition, imaging modalities such as OCT characteristically reveal an empty hypore flective space in the internal structure of a serous ...choroidal imaging, it was unclear if the optically empty space was ...

11

Multimodality Imaging Of Torpedo Maculopathy With Swept-Source, En Face Optical Coherence Tomography And Optical Coherence Tomography Angiography.

Multimodality Imaging Of Torpedo Maculopathy With Swept-Source, En Face Optical Coherence Tomography And Optical Coherence Tomography Angiography.

... Multimodality imaging was undertaken with fundus photography, AF scanning (Spectralis, Heidelberg Engineering, Dossenheim, Germany), SS-OCT (DRI-OCT Atlantis,Topcon Medical Systems, Oakland, New Jersey, USA), ...

10

Optical coherence tomography and optical coherence tomography angiography in uveitis : a review

Optical coherence tomography and optical coherence tomography angiography in uveitis : a review

... alessandro.invernizzi@gmail.com Optical coherence tomography (OCT) has dramatically changed the understanding and management of uveitis and other ocular ...these imaging tech- niques in the ...

15

Noise statistics of phase-resolved optical coherence tomography imaging: single-and dual-beam-scan Doppler optical coherence tomography

Noise statistics of phase-resolved optical coherence tomography imaging: single-and dual-beam-scan Doppler optical coherence tomography

... http://optics.bk.tsukuba.ac.jp/COG/ Abstract: Noise statistics of phase-resolved optical coherence tomogra- phy (OCT) imaging are complicated and involve noises of OCT, correlation of signals, and ...

20

Development of Molecular Contrast-enhanced Imaging for Optical Coherence Tomography

Development of Molecular Contrast-enhanced Imaging for Optical Coherence Tomography

... When precise control of interpulse delay was required, the Ti:Sapphire was utilized as the probe and the Q-switched pump was triggered by a sync pulse from the Ti:Sapphire pulse picker, which enabled temporal ...

138

Granular Cell Tumor Imaging Using Optical Coherence Tomography

Granular Cell Tumor Imaging Using Optical Coherence Tomography

... OCT imaging of GCT could perhaps provide a novel way to accurately delineate tumor margins to plan surgical excision to prevent further GCT ...ing imaging modalities, eg, photoacoustic imaging, may ...

10

In vivo imaging in the oral cavity by endoscopic optical coherence tomography

In vivo imaging in the oral cavity by endoscopic optical coherence tomography

... the imaging of the epithelial thickness end ridges of the oral mucosa, as well as irregular epithelial ...EOCT probe offers appropriate axial and lateral resolution, even small structural alteration could ...

15

Retinal imaging with optical coherence tomography: a biomarker in multiple sclerosis?

Retinal imaging with optical coherence tomography: a biomarker in multiple sclerosis?

... Future directions: validating OCT as a biomarker in MS There is an emerging body of evidence supporting the utility of OCT as an affordable and relatively accessible biomarker in MS. Certainly, the pathobiological ...

17

Versatile optical coherence tomography system applied for imaging of teeth

Versatile optical coherence tomography system applied for imaging of teeth

... The system can collect A-scan (reflectivity versus depth graph), longitudinal (B-scan) and en-face (C-scan) OCT images, simultaneously with a confocal image.. The OCT images showed carie[r] ...

7

Photoacoustic Reporter Gene Imaging And Optical Coherence Computed Tomography

Photoacoustic Reporter Gene Imaging And Optical Coherence Computed Tomography

... In terms of iPOM, the next technical advance will be integrating the complementary functional imaging capabilities of PAI and OCT into the system. PAI could quantify the local hemoglobin concentration and blood ...

119

Characterization of optical fiber imaging bundles for swept-source optical
coherence tomography

Characterization of optical fiber imaging bundles for swept-source optical coherence tomography

... for imaging that reference beam power should be significantly greater than sample beam power; otherwise, the im- age will be confused by signals resulting from inter- ference between various sample-arm ...

14

OPTICAL COHERENCE TOMOGRAPHY (OCT) IS AN

OPTICAL COHERENCE TOMOGRAPHY (OCT) IS AN

... ● METHODS: Imaging was performed with time- and spectral-domain OCT instruments in 15 and 10 normal healthy subjects, respectively. A dedicated software algo- rithm was developed for boundary detection based on a ...

10

OPTICAL COHERENCE TOMOGRAPHY (OCT) IS A

OPTICAL COHERENCE TOMOGRAPHY (OCT) IS A

... OCT IMAGING: SD OCT imaging was accomplished with the Spectralis SD OCT (Heidel- berg Engineering), using the automatic real-time (ART) eye tracker to eliminate motion ...

8

Optical Coherence Tomography (OCT) for

Optical Coherence Tomography (OCT) for

... Moptim Imaging Technical, Nidek, Nine Point Medical, Novacam, OptoMedical Technologies, Optopol (Canon), Optos, Optovue, P&P Optica, Perimeter Medical Imaging, Phoenix Research Labs, Santec, Schwind Eye ...

5

Show all 10000 documents...

Related subjects