• No results found

orthodontic mini-screw implants

The effect of surface characteristics and antimicrobial agents on the growth of biofilms on orthodontic mini-screw implants

The effect of surface characteristics and antimicrobial agents on the growth of biofilms on orthodontic mini-screw implants

... alloy mini-implants and their types, properties, and loading behaviour 141 125 142 ...steel mini-implants are ...titanium implants including rough or smooth surfaces, and the presence ...

238

Distance to alveolar crestal bone: a critical factor in the success of orthodontic mini-implants

Distance to alveolar crestal bone: a critical factor in the success of orthodontic mini-implants

... The clinical implication would be to insert the screw away from the crestal edge at a level where a thicker layer of bone would account for the observed stability. Combin- ing this directive with the indication to ...

7

EFFECT OF ANGLED INSTALLATION OF ORTHODONTIC MINI-IMPLANTS ON PRIMARY STABILITY

EFFECT OF ANGLED INSTALLATION OF ORTHODONTIC MINI-IMPLANTS ON PRIMARY STABILITY

... for$ screw$ and$ the$ patient;$ wherefore,$ the$ mini; implant$design,$the$bone$quality,$the$technique$ and$the$ inclination$of$ install$ are$ factors$ to$ ...

7

Evaluation of inter-radicular spaces and cortical bone thickness at common orthodontic mini-screw implant placement sites using cone beam computed tomography

Evaluation of inter-radicular spaces and cortical bone thickness at common orthodontic mini-screw implant placement sites using cone beam computed tomography

... Miniscrews have been extensively used in orthodontics in the last few years for obtaining absolute orthodontic skeletal anchorage. Many studies have been found in literature addressing the subject. However, there ...

6

Evaluation of center of resistance of maxillary anterior segment when retracting with lingual appliance, sliding mechanics and palatal mini-screw implants: A Finite Element study

Evaluation of center of resistance of maxillary anterior segment when retracting with lingual appliance, sliding mechanics and palatal mini-screw implants: A Finite Element study

... lingual orthodontic treatment. He advocates at least 6mm of the screw portion into the bone for maxillary ...12mm screw; midpalatal thinner mucosa, use a 6 to 7 mm screw; buccal alveolar ...

119

Evaluation of orthodontic mini-implant placement: a CBCT study

Evaluation of orthodontic mini-implant placement: a CBCT study

... of mini-implant surface with the neighboring root in the CBCT ...twenty mini-implants in the RVG group showed root contact while others followed a path with varying amounts of linear and angular ...

9

Simplified tooth movement with mini implants and orthodontic elastics: A prosthodontic approach

Simplified tooth movement with mini implants and orthodontic elastics: A prosthodontic approach

... Implant supported screw-retained provisional crown (Fig 19) 1 . Figure shows open contact point of 1.5mm distally, at 2-week follow-up appointment (Fig 20) 1 . Implant- supported final restoration is shown in (Fig ...

5

Intraoral clinical evaluation of effectiveness of mini implants in orthodontic patients with premolar extraction

Intraoral clinical evaluation of effectiveness of mini implants in orthodontic patients with premolar extraction

... the mini-implants which failed during the procedure were due to peri-implantitis, though antibacterial mouthrinse was prescribed and oral hygiene instructions was given to the patients after the placement ...

5

Mechanical Consideration of Mini-Implants - A Short Review

Mechanical Consideration of Mini-Implants - A Short Review

... of orthodontic anchorage, utilising orthodontic mini-implants (OMIs), also known as mini-screw implants and temporary anchorage devices ...

5

Characteristics and types of mini implants: literature review

Characteristics and types of mini implants: literature review

... Introduction: Orthodontic Movements are given by means of the specific wires inserted in ...suggest mini implants, which are devices used as an auxiliary mechanism for resistance to movement ...of ...

6

Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: a systematic review

... the screw. This procedure reduces the resistance in the bone when implants are ...fractured implants were only identified in the eligible studies that used the self-drilling technique [25, ...

19

The accuracy and safety of patient-specific 3D printing screws insertion templates based on external fixation for pelvic screw insertion

The accuracy and safety of patient-specific 3D printing screws insertion templates based on external fixation for pelvic screw insertion

... the screw were designed in 3D ...optimal screw path was found using the reverse engineering technique to make sure that the virtual cylindrical implant was totally in the bony structure and did not ...

11

Orthodontic palatal implants: clinical technique

Orthodontic palatal implants: clinical technique

... To enable the optimal length of implant to be placed without either perforating the lining of the nasal cavity or damaging the apices of the upper incisors, careful plan- ning is essential. A stent is required to remove ...

7

Mini Implants   A new Era in Orthodontics

Mini Implants A new Era in Orthodontics

... Brånemark implants were allowed to heal for 6 weeks,the implants were loaded for 14 days either statically (constant loads of uniform force levels), dynamically (cyclic loads of variable force levels), or ...

6

THE SUM AND SUBSTANCE OF SKELETAL ANCHORAGE SYSTEM – A NARRATIVE REVIEW

THE SUM AND SUBSTANCE OF SKELETAL ANCHORAGE SYSTEM – A NARRATIVE REVIEW

... dental implants and the host bone with the ...the screw and ...steel screw, a 5% threshold of bone-to-implant contact lead to increased survival rate ...

6

Comparison of effects of twin block and Forsus anchored on orthodontic mini implants on skeletal, Dento alveolar and soft tissue structures

Comparison of effects of twin block and Forsus anchored on orthodontic mini implants on skeletal, Dento alveolar and soft tissue structures

... to mini implants in the mandible to prevent any further ...with orthodontic mini-implants limited the mandibular incisor ...the mini-implant–anchored Forsus Fatigue Resistant ...

6

Incidence of pulp sensibility loss of anterior teeth after paramedian insertion of orthodontic mini-implants in the anterior maxilla

Incidence of pulp sensibility loss of anterior teeth after paramedian insertion of orthodontic mini-implants in the anterior maxilla

... that orthodontic tooth movement can affect PST response temporarily [6], but sensibility is thought to return to normal after completion of ...following orthodontic therapy have been occa- sionally reported ...

7

Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review

Insertion torque recordings for the diagnosis of contact between orthodontic mini-implants and dental roots: protocol for a systematic review

... which implants are de- liberately inserted into dental ...of implants with the target condition, and the underreporting of adverse effects of interventions ...

15

Early loading of plalatal implants (ortho type II) a prospective multicenter randomized controlled clinical trial

Early loading of plalatal implants (ortho type II) a prospective multicenter randomized controlled clinical trial

... For sample size calculation an implant failure rate of 5 % for group 1 (implant loading after a post-surgical healing period of 12 weeks) an implant failure rate of 25 % for group 2 (early implant loading within 1 week ...

7

Use of orthodontic mini-screws among orthodontists in Saudi Arabia

Use of orthodontic mini-screws among orthodontists in Saudi Arabia

... of mini-screws in clinical ...with mini-screws as a result of attending seminars and workshops or reading ...with mini-screws, 82.7% had used mini-screws in ...

6

Show all 4295 documents...

Related subjects