• No results found

Permanent-Magnet Induction Generator

Performance of a Wind Diesel Hybrid Power System with STATCOM as a Reactive Power Compensator

Performance of a Wind Diesel Hybrid Power System with STATCOM as a Reactive Power Compensator

... The paper deals with automatic reactive power control of an isolated wind-diesel hybrid power system. The power is generated by diesel engine and wind turbine as prime movers with electrical power conversion by ...

7

Modelling and controlof a Wind Turbine using Permanent Magnet Synchronous Generator

Modelling and controlof a Wind Turbine using Permanent Magnet Synchronous Generator

... control[1].Both induction and synchronous generators can be used for wind turbine systems ...of induction generators are used in wind power conversion systems: cage rotor, wound rotor with slip control and ...

8

Permanent Magnet Synchronous Generator Based Energy Conversion System: A Review

Permanent Magnet Synchronous Generator Based Energy Conversion System: A Review

... electrical generator system of the wind turbine includes all components for converting mechanical energy in to electrical ...the generator has been illustrated here In [1] author present existing constant ...

5

Optimal Generator Design For Gearless Wind Turbine

Optimal Generator Design For Gearless Wind Turbine

... Both induction and synchronous generators can be used for wind turbine systems ...of induction generators are used in wind power conversion systems: cage rotor, wound rotor with slip control and doubly fed ...

5

A Review of MPPT Algorithms Employed in Wind Energy Conversion System

A Review of MPPT Algorithms Employed in Wind Energy Conversion System

... doubly-fed induction generator (DFIG) and permanent magnet synchronous generator (PMSG) based systems are preferred over fixed-speed WECS like squirrel cage induction ...

6

Maximum Power Tracking of Permanent Magnet Synchronous Generator in Wind Technology

Maximum Power Tracking of Permanent Magnet Synchronous Generator in Wind Technology

... Cage Induction Generator (SCIG), Synchronous Generator with external field excitation, Doubly Fed Induction Generator (DFIG) and Permanent Magnet Synchronous ...

6

Isolated Wind Power Generation Employing PMSG with V-f Controller

Isolated Wind Power Generation Employing PMSG with V-f Controller

... excited induction generators (SEIG) [4-7] and synchronous generators such as diesel generator set and permanent magnet synchronous generator[6-11] are used in wind power generation ...

9

Performance Analysis of Composite Magnetic Circuit Permanent Magnet Wind Generator

Performance Analysis of Composite Magnetic Circuit Permanent Magnet Wind Generator

... circuit permanent magnet generator, which changes the relation- ship between the magnetic induction intensity and the air gap by changing the structure of the main magnetic ...the ...

8

Analysis of optimum coil parameter of permanent magnet generator for energy harvesting application

Analysis of optimum coil parameter of permanent magnet generator for energy harvesting application

... using generator. The generator converts mechanical energy to electrical ...The generator was first discovered by the famous Michael Faraday in 1831 based on the principle of electromagnetic ...

24

Single-Phase Permanent Magnet Dual Stator Induction Generator

Single-Phase Permanent Magnet Dual Stator Induction Generator

... power induction generator is designed and developed using local ...the generator comprises an inner stator as first layer and second layer of outer stator in between this two stator assembly magnetic ...

8

Performance Characteristics of Non-Arc Double Stator Permanent Magnet Generator

Performance Characteristics of Non-Arc Double Stator Permanent Magnet Generator

... non-arc permanent magnets is embedded between the pole ...the permanent magnet from being displaced from its original position as it is designed for high speed ...

14

A Novel Double-Stator Permanent Magnet Generator Integrated with a Magnetic Gear

A Novel Double-Stator Permanent Magnet Generator Integrated with a Magnetic Gear

... Figure 5(a) illustrates the average transmission torques of the three PM rotors in the magnetic gear and their simulation results are 24.80 Nm, 3.47 Nm and 4.16 Nm respectively. The simulated transmission torque ratio is ...

12

Ferrite based axial flux permanent magnet generator for wind turbines

Ferrite based axial flux permanent magnet generator for wind turbines

... of generator active materials (i.e. magnet, copper and iron), the generator losses and the importance of reducing the ...of generator in terms of annual energy yield per cost, which is ...

6

A low-power, linear, permanent-magnet generator/energy storage system

A low-power, linear, permanent-magnet generator/energy storage system

... the generator having the parame- ters given in Table I, the variation of over a complete stroke is less than 20%, having a maximum value of ...a permanent magnet with a recoil permeability which is ...

10

The Development of a New Type Rooftop Ventilator  Turbine

The Development of a New Type Rooftop Ventilator Turbine

... round 24 hours a day free of charge. The additional func- tion of this product is to produce the electrical energy from the roof ventilator that will spin when the wind ex- ist. The consumers not just can enjoy the ...

5

Performance Analysis of Permanent Magnet Vernier Generator under Mechanical Faults

Performance Analysis of Permanent Magnet Vernier Generator under Mechanical Faults

... PM generator (CPMG) with outer rotor configuration is com- pared with that of studied ...and permanent magnets are kept constant in both generators and they are rotated with the same ...

11

Flux weakening control of electric starter generator based on permanent magnet machine

Flux weakening control of electric starter generator based on permanent magnet machine

... Abstract— The paper presents control analysis and design for a Permanent Magnet Machine (PMM) operated in Flux-Weakening (FW) mode for an aircraft electric starter-generator application. Previous ...

13

Significance of Workforce Management to Organizational Performance:  A Study of Islamic Banks in Bahrain

Significance of Workforce Management to Organizational Performance: A Study of Islamic Banks in Bahrain

... Permanent magnet alternators are the most powerful and cost-effective solution for building a wind ...of permanent magnet material and follows the progress of control theory of AC electric ...

6

Induction motors versus permanent magnet actuators for aerospace applications

Induction motors versus permanent magnet actuators for aerospace applications

... Abstract—This paper introduces a comparative study on the design of aerospace actuators concerning Induction Motor (IM) and Permanent Magnet Motor (PMM) technologies. In the analysis undertaken, the ...

10

No Load Performance of a Novel Synchronous Permanent Magnet Generator with Soft Magnetic Composite

No Load Performance of a Novel Synchronous Permanent Magnet Generator with Soft Magnetic Composite

... Wind is one of the most available clean energies in the world. Wind energy is originated by the power of sun but, even when the sun on the night or cloudy days is not available, one may use its energy indirectly via a ...

6

Show all 10000 documents...

Related subjects