• No results found

plasma device

Introduction of a new atmospheric pressure plasma device and application on tomato seeds

Introduction of a new atmospheric pressure plasma device and application on tomato seeds

... pressure plasma device, to explore appropriate voltage of plasma treatment that promote traits and yield of to- mato, tomato seeds were treated by plasma at 4760 to 6800 V, and traits and ...

5

Dependence of Plasma Parameters on Plate Separation and Filament Location in a Double Plasma Device

Dependence of Plasma Parameters on Plate Separation and Filament Location in a Double Plasma Device

... double plasma device and also used two sets of filaments placed at dif- ferent distances from the plates to see their effect on the electron temperature and plasma density in both the source as well ...

7

Design and Operation of First Egyptian IEC Fusion Plasma Device

Design and Operation of First Egyptian IEC Fusion Plasma Device

... Hydrogen gas is substituted for deuterium or tritium because in this configuration the main function of gas ions is to provide electron Bremsstrahlung emission. Intense emission is concentrated in a small volume ...

8

Jiang, Ke
  

(2011):


	Particle manipulation in plasma device & Dynamics of binary complex plasma.


Dissertation, LMU München: Fakultät für Physik

Jiang, Ke (2011): Particle manipulation in plasma device & Dynamics of binary complex plasma. Dissertation, LMU München: Fakultät für Physik

... the plasma sheath straightens the orbits of the bombarding ions so that the etching can be anisotropic, allowing the creation of features approaching nanometer ...in plasma because there are many precursors ...

110

Helium Volumetric Recombining Plasma Formation for Energetic Ion Injection in Radio-Frequency Plasma Device DT-ALPHA

Helium Volumetric Recombining Plasma Formation for Energetic Ion Injection in Radio-Frequency Plasma Device DT-ALPHA

... (RF) plasma device was investigated in two different plasma production ...cylindrical plasma at a higher RF heating power and lower neutral pressure ...the plasma column at a lower RF ...

6

Development of Ion Sensitive Probe and Its Application to RF Plasma Device DT-ALPHA

Development of Ion Sensitive Probe and Its Application to RF Plasma Device DT-ALPHA

... divertor plasma simulator for conducting experimental studies on the afore- mentioned ...(RF) plasma device to study divertor plasma, and helium volumetric recombining plasma production ...

7

Magnetic Field Configuration Dependence of Plasma Production and Parallel Transport in a Linear Plasma Device NUMBER

Magnetic Field Configuration Dependence of Plasma Production and Parallel Transport in a Linear Plasma Device NUMBER

... linear plasma device NUMBER (Nagoya Univer- sity Magnetoplasma Basic Experiment) was designed and constructed to develop a new method of generating ener- getic ...the device are a uni- form magnetic ...

5

Practical Calculation of Nuclear Fusion Power for a Toroidal Plasma Device with Magnetic Confinement

Practical Calculation of Nuclear Fusion Power for a Toroidal Plasma Device with Magnetic Confinement

... Radial and angle dependence of the ion distribution function is studied experimentally by means of passive line-integral and active localized charge exchange neu- tral particle diagnostics [7, 8]. An extensive diagnostic ...

7

Characterization of an Atmospheric Air Non-thermal Plasma Device in Relation to Ozone Production

Characterization of an Atmospheric Air Non-thermal Plasma Device in Relation to Ozone Production

... The plasma characteristics of the TNBR NTP discharge has been determined by simulation using a line ratio code developed with MATLAB. Amongst the discharge parameters that were calculated include the reduced ...

5

Morphology and Optical Property Changes of Nanostructured Tungsten in LHD

Morphology and Optical Property Changes of Nanostructured Tungsten in LHD

... Nanostructured tungsten formed by the exposure to helium plasma in a linear plasma device was installed in the large helical device (LHD). After the exposure in a series of experiments in the ...

9

Conceptual Design of DC Power Supplies for FFHR Superconducting Magnet

Conceptual Design of DC Power Supplies for FFHR Superconducting Magnet

... Helical Device (LHD) ...fusion plasma device but a fusion power plant, and the requirements of the power system for the superconducting coils differ from those of the LHD For example, the magnetic ...

5

Plasma Particle Trajectory Study for a Device Combining Hollow Cathode Discharge and Non-Adiabatic Trap

Plasma Particle Trajectory Study for a Device Combining Hollow Cathode Discharge and Non-Adiabatic Trap

... the plasma increases, and the acceleration of the secondary electron emission can be expected as an e ff ect of the mag- netic field in the device, which we describe as ...

5

Experiments of Plasma Current Start-Up in Tokamak-Helical Hybrid Device TOKASTAR-2

Experiments of Plasma Current Start-Up in Tokamak-Helical Hybrid Device TOKASTAR-2

... Presently we use a DC power supply for VF coils, however, we intend to use pulsed current by capacitors. Using TOSCA code, we evaluated required VF coil current and induced eddy current on the vacuum chamber. The TOSCA ...

6

Particle Orbit Analysis in the Finite Beta Plasma of the Large Helical Device using Real Coordinates

Particle Orbit Analysis in the Finite Beta Plasma of the Large Helical Device using Real Coordinates

... beta plasma of the Large Helical Device (LHD) are numerically traced in a real coordinate ...beta plasma of the ...beta plasma is larger than that in the vacuum magnetic ...beta plasma ...

9

A New Energy Device for Skin Activation to Acute
Wound Using Cold Atmospheric Pressure Plasma: A
Randomized Controlled Clinical Trial

A New Energy Device for Skin Activation to Acute Wound Using Cold Atmospheric Pressure Plasma: A Randomized Controlled Clinical Trial

... Roles and Future Prospect of Cap in Medical Practice There were no significant differences in any of the evaluated items between the groups treated with CAP, ointment, and bFGF. Steroids are often used as an ...

8

Dynamics of mather type plasma focus with step anode configuration

Dynamics of mather type plasma focus with step anode configuration

... I am mostly grateful and indebtedness to Emeritus Prof. Dr. Lee Sing for his guidance, comment and suggestions. I wish to express my gratitude to the local and international Plasma Focus research fellows, Prof. ...

34

The Investigation Capability of Plasma Focus Device for 13N Radioisotope Production by Means of Deuteron Experimental Spectrum

The Investigation Capability of Plasma Focus Device for 13N Radioisotope Production by Means of Deuteron Experimental Spectrum

... positron emission tomography (PET). These radioisotopes are obtained through bombarding appropriate targets by ion beams produced in accelerators. Due to the short half-life of such radioisotopes, which is one of the ...

7

Mode Purity of Electron Cyclotron Waves after Their Passage through the Peripheral Plasma in the Large Helical Device

Mode Purity of Electron Cyclotron Waves after Their Passage through the Peripheral Plasma in the Large Helical Device

... We validate PARADE by comparing its predictions with those of LHDGauss. The propagation of an ECW beam with frequency f = 77 GHz is simulated for two different situations in actual LHD experiments. This fre- quency is ...

5

Performance of a Novel Low Cost, Instrument Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study

Performance of a Novel Low Cost, Instrument Free Plasma Separation Device for HIV Viral Load Quantification and Determination of Treatment Failure in People Living with HIV in Malaysia: a Diagnostic Accuracy Study

... The dried blood spot (DBS) can be used as an alternative sample type to plasma for improving access to VL testing in LMICs (8). The use of DBS can simplify sample collection as well as transportation issues and ...

9

Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly

Preliminary clinical evaluation of a noninvasive device for the measurement of coagulability in the elderly

... the device prior to starting the measurement session, in order to change the blood flow status at the measurement location area ...The device does not require any special ...

6

Show all 10000 documents...

Related subjects