• No results found

Potentiometric sensors

Solid Contact Risperidone Potentiometric Sensors

Solid Contact Risperidone Potentiometric Sensors

... . Potentiometric sensors incorporated with ion-pair associates [21, 22] are generally plagued by limited selectivity and their applications are restricted to more challenging matrices; therefore more ...

13

All Solid Sate Potentiometric Sensors for the Measurement of Paroxetine in Pharmaceutical Formulation

All Solid Sate Potentiometric Sensors for the Measurement of Paroxetine in Pharmaceutical Formulation

... One of the most important parameter of each sensor is its selectivity. The selectivity of an ion-selective electrode is tendency of the sensing element to the analyte in the presence of interfering species. The ...

13

Ag/AgCl Film Electrodes Coated with Agarose Gel as Planar Reference Electrodes for Potentiometric Sensors

Ag/AgCl Film Electrodes Coated with Agarose Gel as Planar Reference Electrodes for Potentiometric Sensors

... Abstract Silver/silver chloride (Ag/AgCl) is commonly used as a reference electrode in electrochemical measurements. However, commercial macroscopic Ag/AgCl electrodes cannot be used in micro-electrochemical ...

7

Solid Contact Potentiometric Sensors Based on Host-Tailored Molecularly Imprinted Polymers for Creatine Assessment

Solid Contact Potentiometric Sensors Based on Host-Tailored Molecularly Imprinted Polymers for Creatine Assessment

... rate.Potentiometric sensors have alsobecome the criterion approach for quantifying several ...contact-based sensors during the last few decades has created a “silent uprising” [3] that have led to stronger ...

12

A Simple and Convenient Set-Up of Light Addressable Potentiometric Sensors (LAPS) for Chemical Imaging Using a Commercially Available Projector as a Light Source

A Simple and Convenient Set-Up of Light Addressable Potentiometric Sensors (LAPS) for Chemical Imaging Using a Commercially Available Projector as a Light Source

... addressable potentiometric sensors (LAPS) are important semiconductor based label free sensing tools that are useful for visualizing the 2-D distribution of chemical species because of their light ...

13

Carbon Potentiometric Sensors Modified with Beta-cyclodextrin as a Carrier for the Determination of Bisoprolol Fumarate

Carbon Potentiometric Sensors Modified with Beta-cyclodextrin as a Carrier for the Determination of Bisoprolol Fumarate

... (potentiometric sensors) is easy, inexpensive and ...proposed sensors listed in Tables (6, 7) indicated the effective use of the sensors for determination of BPF with a good agreement with ...

14

B-Cyclodextrin-Based Potentiometric Sensors for Flow-Injection Determination of Acetylcholines

B-Cyclodextrin-Based Potentiometric Sensors for Flow-Injection Determination of Acetylcholines

... The beauty of electrochemical techniques is to utilize a chemically modified electrode (CME) tailor fabricated by incorporation of a suitable modifier for sensitive and selective analytical applications. Cyclodextrins ...

11

Ciprofloxacin Nano-Composite Carbon Paste and PVC Membrane Potentiometric Sensors

Ciprofloxacin Nano-Composite Carbon Paste and PVC Membrane Potentiometric Sensors

... Ciprofloxacin is a synthetic antibiotic of the fluoroquinolone drug class. Two kinds of potentiometric sensors were introduced for determination of ciprofloxacin. Ciprofloxacin-tetraphenyl borate ion-pair ...

13

Two Novel Potentiometric Sensors for Determination of Clonidine in Some Pharmaceutical Formulation

Two Novel Potentiometric Sensors for Determination of Clonidine in Some Pharmaceutical Formulation

... membrane sensors with cylindrical configuration for clonidine HCl have been ...Both sensors showed a significant response to clonidine with near-Nernstian cationic slope of 53 and 54 mV/ decade over a ...

14

New potentiometric sensors for methylphenidate detection based on host–guest interaction

New potentiometric sensors for methylphenidate detection based on host–guest interaction

... membrane sensors were assessed for the effect of using different plasticizers in relation to their analytical ...methylphenidate sensors compared with ...the sensors; however, in the case of o-NPOE ...

10

Modified Screen Printed and Carbon Paste Ion Selective Electrodes for Potentiometric Determination of Naphazoline Hydrochloride in Pure and Pharmaceutical Preparations

Modified Screen Printed and Carbon Paste Ion Selective Electrodes for Potentiometric Determination of Naphazoline Hydrochloride in Pure and Pharmaceutical Preparations

... used potentiometric sensors during laboratory analysis as well as in industry, process control, physiological measurements, and environmental monitoring ...

16

Novel Pioglitazone Nanomaterial Based Screen Printed Sensors

Novel Pioglitazone Nanomaterial Based Screen Printed Sensors

... disposable potentiometric sensors for determination of pioglitazone hydrochloride (PIO) have been ...that sensors incorporated with 15-crown-5 ether as sensing ionophore, sodium tetrakis ...

13

Determination of Midazolam by Potentiometric PVC membrane and MWCNTs based Carbon Paste Sensors

Determination of Midazolam by Potentiometric PVC membrane and MWCNTs based Carbon Paste Sensors

... of potentiometric sensors which are widely used and have different application in analysis of ionic species ...membrane sensors is their low physical and mechanical resistance for long-term ...of ...

12

Potentiometric Membrane Sensors for the Selective Determination of Memantine Hydrochloride in Pharmaceutical Preparations

Potentiometric Membrane Sensors for the Selective Determination of Memantine Hydrochloride in Pharmaceutical Preparations

... Three potentiometric sensors responsive to Memantine HCl (MEM) drug are described, characterized, compared and used for drug ...The sensors are based on the use of the ion-association complex of ...

16

All Solid State Screen Printed Sensors for Potentiometric Calcium(II) Determinations in Environmental Samples

All Solid State Screen Printed Sensors for Potentiometric Calcium(II) Determinations in Environmental Samples

... DOI: 10.4236/ajac.2018.93010 114 American Journal of Analytical Chemistry great interest for easy to use, sensitive, low-cost and maintenance-free chemical analyzers for economical real-time analysis of environmentally ...

11

MIP-Based Biomimetic Sensors for Static and Hydrodynamic Potentiometric Transduction of Sitagliptin in Biological Fluids

MIP-Based Biomimetic Sensors for Static and Hydrodynamic Potentiometric Transduction of Sitagliptin in Biological Fluids

... STG potentiometric sensors were fabricated from an MIP based on the use of MAA or 2-VP as a functional monomer exhibited excellent potentiometric performances such as fast response, a wide working pH ...

13

Comparative study of β-cyclodextrin, γ-cyclodextrin and 4-tert-butylcalix[8]arene ionophores as electroactive materials for the construction of new sensors for trazodone based on host-guest recognition

<p>Comparative study of &beta;-cyclodextrin, &gamma;-cyclodextrin and 4-<em>tert</em>-butylcalix[8]arene ionophores as electroactive materials for the construction of new sensors for trazodone based on host-guest recognition</p>

... of potentiometric sensors in pharma- ceutical and medicinal analysis 17,18 has attracted increasing interest, because such sensors offer high sen- sitivity, reproducibility and low ...metric ...

11

Potentiometric Determination of Betahistine in Pharmaceutical Formulations by Drug Selective Sensors

Potentiometric Determination of Betahistine in Pharmaceutical Formulations by Drug Selective Sensors

... In comparison with complicated and time consumed techniques, potentiometric sensors offer the advantages of rapid, portable and inexpensive method of analysis. Although they cannot be considered as very ...

11

Pramipexole Symmetric and Asymmetric Potentiometric PVC Membrane Sensors

Pramipexole Symmetric and Asymmetric Potentiometric PVC Membrane Sensors

... of potentiometric sensors was produced for determination of Pramipexole ...membrane sensors were made for the measurement of Pramipexole ingredient in some pharmaceutical ...

12

Comparative Investigation of β- and γ-cyclodextrin as Ionophores in Potentiometric Based Sensors for Naltrexone

Comparative Investigation of β- and γ-cyclodextrin as Ionophores in Potentiometric Based Sensors for Naltrexone

... investigated sensors show a good selectivity for NALT with respect of different ...for sensors 1 and 2. The examined sensors have been used for the assay of NALT in its dosage ...investigated ...

13

Show all 4158 documents...