• No results found

proximal locking compression plate

Internal fixation of unstable intertrochanteric fractures with sliding hip screw and proximal locking compression plate: A short term prospective and comparative study

Internal fixation of unstable intertrochanteric fractures with sliding hip screw and proximal locking compression plate: A short term prospective and comparative study

... This is to certify that this dissertation in “INTERNAL FIXATION OF UNSTABLE INTERTROCHANTERIC FRACTURES WITH SLIDING HIP SCREW AND PROXIMAL LOCKING COMPRESSION PLATE – A SHORT TERM PROSPECTIVE ...

91

Surgical Management Of Proximal Humerus Fractures By Philos Locking Plate

Surgical Management Of Proximal Humerus Fractures By Philos Locking Plate

... on compression between the plate undersurface and bone for stability, this is not the case for the ...the plate/bone interface is not loaded along the screw ...and plate fixation is ...

8

Study on the Efficiency of Fractures Treated With Proximal Femoral Locking Compression Plate Ravi G.O 1, Shaik Hussain Saheb *2

Study on the Efficiency of Fractures Treated With Proximal Femoral Locking Compression Plate Ravi G.O 1, Shaik Hussain Saheb *2

... lateral plate is superior to a compression hip screw to support the lateral aspect of the greater trochanter in unstable ...the proximal fragment and maintaining an anatomical ...

5

Functional and Radiological outcome of proximal humeral fractures treated with locking compression plates (Philos plates): A prospective study

Functional and Radiological outcome of proximal humeral fractures treated with locking compression plates (Philos plates): A prospective study

... PHILOS plate was placed atleast 8mm distal to the upper ened of the greater ...The plate was then placed lateral to the long head of biceps with out compromising its ...with locking head ...length ...

153

Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures

Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures

... the proximal humerus provides limited access to the posterolateral aspect of the shoulder and that the visualization and reduction of a large retracted greater tuberosity fragment may be difficult ...of ...

7

Comparative Study of Management of Proximal Humerus Fractures in Elderly by Conservative Method Versus Operative Locking Compression Plate

Comparative Study of Management of Proximal Humerus Fractures in Elderly by Conservative Method Versus Operative Locking Compression Plate

... A beach-chair position was given to the patient, follow- ing general anaesthesia. The C-arm was positioned prop- erly to view the proximal humerus. Scrubbing, painting and draping of the affected upper limb were ...

8

Functional Outcome of Medial Condyle Fractures of Proximal Tibia Treated using Posteromedial Locking Compression Plate

Functional Outcome of Medial Condyle Fractures of Proximal Tibia Treated using Posteromedial Locking Compression Plate

... range 9%-98%) of the surface area of medial condyle of proximal tibia. Higgins et al., confirmed the fact and showed that the fragment occupied 25% of the total tibial articular surface. Usually it is a split ...

123

A Compartive analysis of functional outcome of tibial plateau fractures treated with proximal tibial locking plate with raft screw technique and conventional buttress plating

A Compartive analysis of functional outcome of tibial plateau fractures treated with proximal tibial locking plate with raft screw technique and conventional buttress plating

... dynamic compression plate was contoured and fixed with screws in distal ...3.5-mm plate acting as a dorsal buttress and was finally fixed with compression screws in a postero-anterior ...

134

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support

... the proximal humeral fracture model according to standard surgical guide- lines [8, 14, 16–19] ...Angle Locking Compression Plate Distal Radius System (VA-LCP, Synthes, Switzerland) were ...

10

High failure rate of proximal femoral locking plates in fixation of trochanteric fractures

High failure rate of proximal femoral locking plates in fixation of trochanteric fractures

... a proximal femoral locking compression plate, the failure rate was 16%, which was lower than the failure rate of 51% in the DHS group of 35 patients with the same type of frac- ...with ...

9

Comparison of Side Effects and Cost Effectiveness of Proximal Femur Locking Compression Plate with Intramedullary Nailing in the Treatment of Sub-Trochanteric Fractures

Comparison of Side Effects and Cost Effectiveness of Proximal Femur Locking Compression Plate with Intramedullary Nailing in the Treatment of Sub-Trochanteric Fractures

... In a study by Glassner et al., it was observed that use of PFLCP can be a simpler approach such as C-Arm imaging, much more X-rays, the patient's harder position for surgery, acceptable results and substitutes for other ...

5

Comparison of Proximal Femur Locking Compression Plate and Intramedullary Nailing in the Treatment of Sub-Trochanteric Fractures

Comparison of Proximal Femur Locking Compression Plate and Intramedullary Nailing in the Treatment of Sub-Trochanteric Fractures

... Eligible patients were first selected by reviewing their medical records. Then, the selected patients were re- evaluated and randomly divided into equal groups A and B. Group A included patients that had used PFLCP to ...

7

Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle

Locking Plate in Proximal Tibial Fracture: A Correlation between the Coronal Alignment of Tibia and Joint Screw Angle

... the proximal most screw through the locking compression plate-proximal lateral tibia (LCP PLT) and the joint line, and to evaluate if this an- gle can be used intraoperatively as an ...

6

Hemiarthroplasty versus angle stable locking compression plate osteosynthesis in the treatment of three  and four part fractures of the proximal humerus in the elderly: design of a randomized controlled trial

Hemiarthroplasty versus angle stable locking compression plate osteosynthesis in the treatment of three and four part fractures of the proximal humerus in the elderly: design of a randomized controlled trial

... The HOMERUS study is designed as a level-1 multicen- ter prospective randomized controlled trial. Four centers in the Netherlands will participate. Eligible patients attending the Emergency Room (ER) with a comminu- ted ...

7

Influence of age, gender, and radiographic features on the deltoid splitting approach for surgical osteosynthesis in displaced proximal humerus fractures: a comparison study

Influence of age, gender, and radiographic features on the deltoid splitting approach for surgical osteosynthesis in displaced proximal humerus fractures: a comparison study

... unilateral proximal humerus fractures that were treated surgically with the Locking Compression Plate (LCP), as per the Neer classifi- cation criteria at our institute between 2009 and ...

6

Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures

Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures

... unstable proximal humeral fractures with poor bone ...14 locking holes and one compression ...eight locking screws into the head and three into the diaphysis for ...the plate will ...

7

Role of locking compression plate for Distal Radius Fractures in Postmenopausal Women

Role of locking compression plate for Distal Radius Fractures in Postmenopausal Women

... This is to certify that this dissertation titled “Role of Locking Compression Plate For Distal Radius Fractures in postmenopausal women” submitted to the Tamil Nadu Dr. M.G.R. Medical University, ...

143

Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?

Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate?

... of locking plates (PH-LCP and PHILOS ...and plate design, including the number of locking holes and the thickness of the plate, both of which can affect the overall ...long locking ...

11

Locking compression plate distal ulna hook plate fixation versus intramedullary screw fixation for displaced avulsion fifth Metatarsal Base fractures: a comparative retrospective cohort study

Locking compression plate distal ulna hook plate fixation versus intramedullary screw fixation for displaced avulsion fifth Metatarsal Base fractures: a comparative retrospective cohort study

... Methods: Of 43 patients with displaced avulsion FMBFs, 18 patients were treated with LCP distal ulna hook plate fixation and 25 were treated with IMS fixation. The patients were evaluated clinically and ...

6

The use of bidirectional rapid reductor in minimally invasive treatment of bicondylar tibial plateau fractures: preliminary radiographic and clinical results

The use of bidirectional rapid reductor in minimally invasive treatment of bicondylar tibial plateau fractures: preliminary radiographic and clinical results

... Bicondylar tibial plateau fractures (AO/OTA type C) rep- resent 20.4% of all proximal tibial fractures [1, 2]. Because of articular comminution and the frequent occurrence soft-tissue injuries, clinical management ...

11

Show all 10000 documents...