• No results found

Steel columns

Experimental Investigation into the Compressive Behavior of Steel Columns with Flange Jointsin Prefabricated Steel Frame Structure

Experimental Investigation into the Compressive Behavior of Steel Columns with Flange Jointsin Prefabricated Steel Frame Structure

... on steel columns with flange joints in prefabricated steel frame ...such steel columns, fifteen specimens were ...non-joint columns, the bearing capacity and bending stiffness of ...

6

Buckling Modes of Cold-Formed Steel Columns

Buckling Modes of Cold-Formed Steel Columns

... cold-formed steel columns were investigated; 2) previous research on built-up columns and testing rigs for column buckling was reviewed; and 3) the authors’ buckling test results of 42 cold-formed ...

5

Elastic Buckling of Steel Columns Under Axial Compression

Elastic Buckling of Steel Columns Under Axial Compression

... Study 1. In Table 1 variations of the buckling loads versus length, which are obtained from FEM and the formula of Euler [4], for steel columns with three different cross sections and F-F ends are given. As ...

7

Axial moment interaction and load path dependency for steel columns

Axial moment interaction and load path dependency for steel columns

... found steel columns are path dependant, with the plastic capacity reducing by up to 18% when the loading occurs in the major and minor axis at the same ...

8

Analysis of Effects of Axial Shortening of Steel Columns in Frame Structure

Analysis of Effects of Axial Shortening of Steel Columns in Frame Structure

... the steel columns of frame structure and also to analyze the probable consequence related to the axial deformation of steel ...of steel column is quite high from ground level to the mid floor ...

5

Effect of Severe Temperatures and Restraint on Instability and Buckling of Elliptical Steel Columns

Effect of Severe Temperatures and Restraint on Instability and Buckling of Elliptical Steel Columns

... (EHS) steel columns sub- jected to severe hydrocarbon ...12 steel col- umns presenting 2 oval sections 200 × 100 × 8 mm and 300 × 150 × 8 mm and yielding 2 slenderness λ = 51 and ...mm columns ...

17

Finite element modelling of cold formed stainless steel columns

Finite element modelling of cold formed stainless steel columns

... stainless steel, subjected to concentric and eccentric compression ...loaded columns and the results obtained are compared with those obtained on the basis of experiments on stainless steel channel ...

7

Survey on Comparison of Steel and Concrete Composite Beam Column Connections

Survey on Comparison of Steel and Concrete Composite Beam Column Connections

... structural steel and reinforced concrete to produce more efficient structures than realized using either material ...structural steel and reinforced concrete in such ...of steel beams and reinforced ...

7

Prestressed Stainless Steel Stayed Columns with Two Crossarms

Prestressed Stainless Steel Stayed Columns with Two Crossarms

... slender steel columns was proved for both stability and strength capacity of the ...stayed columns with just one crossarm is confirmed and the three zones depending on the value of prestressing are ...

10

Reliability Assessment of CFRP-Strengthened Deficient Steel SHS Columns

Reliability Assessment of CFRP-Strengthened Deficient Steel SHS Columns

... damaged steel beams and columns and concluded that the premature debonding failure leading to stress concentration at the notch zone can generally reduce the efficiency of this strengthening ...damaged ...

14

Finite Element Analysis of Steel Tubular Section Filled with Concrete

Finite Element Analysis of Steel Tubular Section Filled with Concrete

... analysis steel tubular section filled with concrete investigation on the behaviour of axially loaded composite concrete filled steel columns strengthened with steel tube as external ...

5

An Experimentalstudy On Concrete Filled Tubular Columns Using Varying Steel Materials

An Experimentalstudy On Concrete Filled Tubular Columns Using Varying Steel Materials

... filled steel tubular columns have been used in different areas of construction and becoming an attractive ...tubular columns in high rise buildings has become popular in recent years as they provide ...

6

Analysis of Tubed Steel Reinforced Columns Under Axial Loading

Analysis of Tubed Steel Reinforced Columns Under Axial Loading

... circular steel–concrete composite stub columns, Zhou and Liu (2010) investigated the seismic behaviour of tubed SRC short columns by testing eight specimens subjected to combined constant axial ...

8

Behaviour of Cold Formed Steel Built Up Columns by using Fasteners

Behaviour of Cold Formed Steel Built Up Columns by using Fasteners

... conducted by Shivakumar Kesawan. Connections are made at the junction of two channels and at end of flanges and at top and bottom of web. Spacing are provided similar to the bolt spacing for comparison. Electrical ...

5

Review on Steel Concrete Composite Column

Review on Steel Concrete Composite Column

... encased steel composite columns. The columns were pin-ended subjected to an eccentric load acting along the major axis, with eccentricity varied from ...The steel section yield stresses also ...

5

Behavior of Reinforced Concrete Columns Strengthened by GFRP with Different Steel Ratio

Behavior of Reinforced Concrete Columns Strengthened by GFRP with Different Steel Ratio

... RC columns by using reinforced steel jackets around circular ...a steel encasement to provide the lateral confinement to concrete in compression has been extensively studied and has been shown to be ...

10

An Experimental Investigation on Axial Strength of Steel Tubular Short Columns Infilled with High Volume GGBS.

An Experimental Investigation on Axial Strength of Steel Tubular Short Columns Infilled with High Volume GGBS.

... all columns failed due to local buckling and concrete ...all columns at the bottom or the top was a typical crushing failure mode where the steel wall was pushed out by the concrete core, which in ...

8

Seismic Behavior of concrete filled steel Tubular Built-up columns

Seismic Behavior of concrete filled steel Tubular Built-up columns

... hollow steel lacing can be welded easily during ...Q345 steel tube, diameter 110mm, thickness 2mm, in-filled with C50 grade concrete; brace with steel tube with diameter 50mm, thickness 2mm, spacing ...

236

Structural Behaviour of Fibre Reinforced Concrete Filled Steel Box Columns

Structural Behaviour of Fibre Reinforced Concrete Filled Steel Box Columns

... filled steel box column behavior, it is primarily due to the interaction between the steel and concrete ...thick steel plate, modeled using (element; SOLID 45 in ...and steel, and consequently ...

7

Show all 10000 documents...

Related subjects