• No results found

The Time Projection Chamber

The Active Target Time Projection Chamber at NSCL

The Active Target Time Projection Chamber at NSCL

... Target Time Projection Chamber (AT-TPC) offers an elegant solution to this ...the time projection chamber is at the same time the target in which nuclear reactions take ...

5

MicroBooNE: A New Liquid Argon Time Projection Chamber Experiment

MicroBooNE: A New Liquid Argon Time Projection Chamber Experiment

... Argon Time Projection Chamber detectors are well suited to study neutrino interactions, and are an intriguing option for future massive detectors capable of measuring the parameters that characterize ...

6

The development of a test setup for the upgrade of the Time Projection Chamber at the ALICE detector

The development of a test setup for the upgrade of the Time Projection Chamber at the ALICE detector

... Diploma thesis title Abstract During the second long shutdown of the Large Hadron Collider at CERN, the de- tectors for high energy collisions must be upgraded to keep track with a significant increase in the particle ...

50

Investigation of Neutron Induced Ternary Fission with the NIFFTE Time Projection Chamber

Investigation of Neutron Induced Ternary Fission with the NIFFTE Time Projection Chamber

... ABSTRACT Ternary fission is a rare occurrence in which three particles are produced from a single fission event. This analysis uses tracked fission event data recorded by NIFFTE’s time projection ...

29

MicroBooNE, A Liquid Argon Time Projection Chamber (LArTPC) Neutrino Experiment

MicroBooNE, A Liquid Argon Time Projection Chamber (LArTPC) Neutrino Experiment

... Argon Time Projection Chamber (LArTPC) Since the LArTPC was first proposed [1], the detection technique has mainly been developed by an Italian collaboration ...

7

OPTIMIZATION OF THE READOUT PAD GEOMETRY FOR A GEM-BASED TIME PROJECTION CHAMBER

OPTIMIZATION OF THE READOUT PAD GEOMETRY FOR A GEM-BASED TIME PROJECTION CHAMBER

... future time projection chamber (TPC) designs strong magnetic fields are fore- seen to reduce transverse cluster sizes and thus improve transverse spatial reso- lution and double-track ...

5

Time Projection Chamber (TPC) detectors for nuclear astrophysics studies with gamma beams

Time Projection Chamber (TPC) detectors for nuclear astrophysics studies with gamma beams

... Time Projection Chamber (TPC) detectors for nuclear astrophysics studies with gamma beams GAI, M, SCHWEITZER, D, STERN, S. R., YOUNG, AH, SMITH, Robin , CWIOK, ...

10

Bivariate normal distribution for finding inliers in Hough space for a Time Projection Chamber

Bivariate normal distribution for finding inliers in Hough space for a Time Projection Chamber

... A Time Projection Chamber (TPC) is foreseen as the main tracking detector for the International Large Detector (ILD), one of the two detectors for the next candidate collider named International ...

9

(W)hole new field: the new GEM Time Projection Chamber of ALICE

(W)hole new field: the new GEM Time Projection Chamber of ALICE

... expense of introducing a significant deadtime limiting the trigger rate to about 3 kHz. Figure 2. The ALICE Time Projection Chamber. The ionization electrons drift parallel to the cylinder axis ...

10

Scaling studies for deep learning in Liquid Argon Time Projection Chamber event classification

Scaling studies for deep learning in Liquid Argon Time Projection Chamber event classification

... 1 902 Battelle Boulevard, P.O.Box 999, Richland, WA 99352, USA 2 Center for High Energy Physics, 1274 University of Oregon, Eugene, OR 97403, USA Abstract. Measurements in Liquid Argon Time Projection ...

7

RWTH Aachen University. Inverse beta decay signatures in a liquid organic time projection chamber

RWTH Aachen University. Inverse beta decay signatures in a liquid organic time projection chamber

... Figure 3 shows the working principle of a time projection chamber for anti-neutrino detection. The anti-neutrino comes into the drift volume filled with TMS and decays into a positron and a neutron. ...

37

Photon detector system performance in the DUNE 35-ton prototype liquid argon time projection chamber

Photon detector system performance in the DUNE 35-ton prototype liquid argon time projection chamber

... Prepared for submission to JINST Photon detector system performance in the DUNE 35-ton prototype liquid argon time projection chamber D. L. Adams 4 T. Alion 24 J. T. Anderson 3 L. Bagby 8 M. Baird ...

19

Breakup, transfer, and fusion studies of exotic “halo” nuclei using an active-target time projection chamber.

Breakup, transfer, and fusion studies of exotic “halo” nuclei using an active-target time projection chamber.

... active-target time projection chamber that is being pre- pared for use with the ReA3 reaccelerated radioactive beam facility at the NSCL will be an extremely useful device for fusion studies of ...

6

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

Photon detector system timing performance in the DUNE 35-ton prototype liquid argon time projection chamber

... 2.3 Time projection chamber The TPC inside the LAr-filled cryostat consisted of an anode plane and two cathode planes, one on either side of the anode ...

19

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

... argon time projection chamber with an active volume of ...the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle ...life- ...

102

Electron hadron shower discrimination in a liquid argon time projection chamber

Electron hadron shower discrimination in a liquid argon time projection chamber

... 2 The set of four discrimination variables applied to the CN2PY beam (see text) Neutrino events. Signal events are defined as electromagnetic shower events from Electrons, compared to th[r] ...

10

Study of Electromagnetic Interactions in the MicroBooNE Liquid Argon Time Projection Chamber

Study of Electromagnetic Interactions in the MicroBooNE Liquid Argon Time Projection Chamber

... available, is sufficient to provide the statistics necessary for this study. The efficiency is quantified by measuring the number of reconstructed Michel electrons over the total number of electrons sim- ulated in a ...

236

Timepix3 as a solid-state time-projection chamber in particle and nuclear physics

Timepix3 as a solid-state time-projection chamber in particle and nuclear physics

... E-mail: [email protected] Timepix3 devices are hybrid pixel detectors developed within the Medipix3 collaboration at CERN providing a simultaneous measurement of energy (ToT) and time of arrival (ToA) ...

8

Image Processing Techniques applied to Liquid Argon Time Projection Chamber(LArTPC) Data

Image Processing Techniques applied to Liquid Argon Time Projection Chamber(LArTPC) Data

... ● The interaction also produces scintillation light which is collected with PMTs and gives the initial time of event. ● The ionization then drifts toward wire-planes and creates signals on the collection and ...

36

Convolutional Neural Networks Applied to Neutrino Events in a Liquid Argon Time Projection Chamber

Convolutional Neural Networks Applied to Neutrino Events in a Liquid Argon Time Projection Chamber

... 5.2 Training We next used our reduced Inception-ResNet-v2 for classification training of two samples: neutrino vs. cosmic events. At the data preparation stage during the training, we perform a random cropping of an ...

65

Show all 10000 documents...

Related subjects