• No results found

total disc replacement

Wear and biological effects of a semi-constrained total disc replacement subject to modified ISO standard test conditions

Wear and biological effects of a semi-constrained total disc replacement subject to modified ISO standard test conditions

... artificial replacement joint performance and for guiding future device design. Total disc replacement wear and the potential for osteolysis is a growing concern, therefore a parametric study ...

21

Influence of preoperative nucleus pulposus status and radiculopathy on outcomes in mono segmental lumbar total disc replacement: results from a nationwide registry

Influence of preoperative nucleus pulposus status and radiculopathy on outcomes in mono segmental lumbar total disc replacement: results from a nationwide registry

... intervertebral disc remains in its infancy [1,2] and interbody fusion in younger patients stays under special scrutiny, there will be ongoing enthusiasm for motion preserving procedures as alternative treatment in ...

9

Mid- to long-term results of total disc replacement for lumbar degenerative disc disease: a systematic review

Mid- to long-term results of total disc replacement for lumbar degenerative disc disease: a systematic review

... lumbar, total disc replacement, and ...lumbar disc re- placements, we performed a broad search of articles, in- cluding both retrospective and prospective cohort ...

12

Adjacent segment degeneration or disease after cervical total disc replacement: a meta-analysis of randomized controlled trials

Adjacent segment degeneration or disease after cervical total disc replacement: a meta-analysis of randomized controlled trials

... Total disc replacement (TDR) on cervical vertebra has been greatly improved over the last decade. Based on a large amount of biomechanical testing, TDR can theoret- ically decrease the incidence of ...

10

WEAR STUDY ON ARTIFICIAL JOINT REPLACEMENT, TOTAL DISC REPLACEMENT- A STATE OF ART REVIEW

WEAR STUDY ON ARTIFICIAL JOINT REPLACEMENT, TOTAL DISC REPLACEMENT- A STATE OF ART REVIEW

... specially total disc replacement under dry and wet sliding conditions for different conditions of loading, lubrication ,different composition of materials, various pH concentration and various others ...

23

Review Article The effect of Mobi-C cervical total disc replacement versus ACDF in symptomatic degenerative disc disease: a meta-analysis of randomized controlled trials

Review Article The effect of Mobi-C cervical total disc replacement versus ACDF in symptomatic degenerative disc disease: a meta-analysis of randomized controlled trials

... Two-level total disc replacement with Mobi-C cervical artificial disc versus ante- rior discectomy and fusion: a prospective, ran- domized, controlled multicenter clinical trial with 4-year ...

8

Wear characteristics of an unconstrained lumbar total disc replacement under a range of in vitro test conditions

Wear characteristics of an unconstrained lumbar total disc replacement under a range of in vitro test conditions

... unconstrained total disc replacement have been investigated using the ISO 18192-1 standard test as a base- ...the disc inferiorly did ...

7

Nanofibrous Disc-Like Angle Ply Structure for Total Disc Replacement in a Small Animal Model

Nanofibrous Disc-Like Angle Ply Structure for Total Disc Replacement in a Small Animal Model

... native disc and DAPS implantations proceeded as described above, though no internal suture was used to secure the DAPS ...of disc height with application of the fixator at 14 (n=2) and 28 days ...

313

Investigation into the Lubrication Regime for Lumbar Total Disc Replacement of the Spine

Investigation into the Lubrication Regime for Lumbar Total Disc Replacement of the Spine

... In vitro wear tests should mimic the wear conditions of TDRs in an in vivo situation. It is therefore relevant that the lubrication regimes for in vitro wear testing and for an in vivo load situation match. In vitro wear ...

9

Fluoroscopic Assessment of Lumbar Total Disc Replacement Kinematics During Walking

Fluoroscopic Assessment of Lumbar Total Disc Replacement Kinematics During Walking

... Summary of background data. TDR is a motion preservation technology that offers an alternative to spinal fusion for treatment of degenerative disc disease. The aim of TDRs is to replicate motion of the functional ...

22

Review Article Dynamic cervical implant in treating cervical degenerative disc disease: a systematic review and meta-analysis

Review Article Dynamic cervical implant in treating cervical degenerative disc disease: a systematic review and meta-analysis

... outcome compared with the traditional fusion surgery, cervical total disc replacement (CTDR) has become a substitute for fusion in recent years [7-9]. The results of a meta-analysis indi- cated that ...

9

Spine imaging after lumbar disc replacement: pitfalls and current recommendations

Spine imaging after lumbar disc replacement: pitfalls and current recommendations

... In the last years the increased availability of positron emission tomography (PET) enabled postoperative diag- nostics with greater specificity for infection. Gratz et al [13] found fluorine-18 fluorodeoxyglucose (FDG) ...

6

Safety and efficacy of cervical disc arthroplasty in preventing the adjacent segment disease: a meta-analysis of mid- to long-term outcomes in prospective, randomized, controlled multicenter studies

<p>Safety and efficacy of cervical disc arthroplasty in preventing the adjacent segment disease: a meta-analysis of mid- to long-term outcomes in prospective, randomized, controlled multicenter studies</p>

... Prodisc-C total disc replacement versus anterior cervical discectomy and fusion for single level symptomatic cervical disc dis- ease: seven year follow-up of the prospective randomized ...

9

Lumbar total disc arthroplasty: outdated surgery or here to stay procedure? A systematic review of current literature

Lumbar total disc arthroplasty: outdated surgery or here to stay procedure? A systematic review of current literature

... keywords: total disc replacement, lumbar disc arthroplasty, degenerative disc disease, out- comes, complications, sagittal ...lumbar total disc replacement were ...

19

Cervical Disc Replacement: A Systematic Review of Medline Indexed Literature

Cervical Disc Replacement: A Systematic Review of Medline Indexed Literature

... cervical disc herniation and Degenerative Disc Disease (DDD) refractory to conservative ...adjacent disc level re- sulting in symptomatic adjacent segment ...cervical disc replacement ...

6

Telerehabilitation Feasibility in Total Joint Replacement

Telerehabilitation Feasibility in Total Joint Replacement

... supporting the use of telerehabilitation in a diverse range of clinical scenarios. Rehabilitation for neurological conditions, cardiac conditions, musculoskeletal conditions, spinal cord injuries, speech-language ...

8

Feasibility study of the design artificial disc replacement prostheses

Feasibility study of the design artificial disc replacement prostheses

... intervertebral disc is responsible to withstand all the compressive loading subjected to vertebral body includes different types of load stresses, like dynamic loads, static loads, tensile stresses, torsional ...

24

Design and Analysis of Brake Rotor (DISC)

Design and Analysis of Brake Rotor (DISC)

... the disc or rotor of disc brake analysis. A disc brake is a type of brake that uses calipers to squeeze pairs of pads against a disc or "rotor"[1] to create ...actuated disc ...

5

MOBILE and the provision of total joint replacement

MOBILE and the provision of total joint replacement

... happening in terms of the prioritization of individuals for a TJR, contrasting this with what they thought should happen, 24 and found that patients, like the health care professionals, think that pain and disability ...

10

Changing trends in total knee replacement

Changing trends in total knee replacement

... All patients underwent a cemented TKR. A tourniquet was used in all cases and let down at the end of the pro- cedure. No drains were used. All patients had a cemented, fixed bearing cruciate retaining knee ...

6

Show all 10000 documents...

Related subjects