• No results found

[PDF] Top 20 Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA

Has 10000 "Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA" found on our website. Below are the top 20 most common "Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA".

Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA

Highly Sensitive Multiplex Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA

... earlier detection of infection because they directly test for the presence of circulating virus rather than measure the indi- vidual’s antibody response to the ...of detection, serves as an indepen- ... See full document

12

Simultaneous Detection of Multiplex Amplified Human Immunodeficiency Virus Type 1 RNA, Hepatitis C Virus RNA, and Hepatitis B Virus DNA Using a Flow Cytometer Microsphere Based Hybridization Assay

Simultaneous Detection of Multiplex Amplified Human Immunodeficiency Virus Type 1 RNA, Hepatitis C Virus RNA, and Hepatitis B Virus DNA Using a Flow Cytometer Microsphere Based Hybridization Assay

... a multiplex assay for the detection of human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) RNAs and hepatitis ... See full document

6

Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA

Multicenter Evaluation of the New Abbott RealTime Assays for Quantitative Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA

... RealTime hepatitis C virus (HCV) and human immunode- ficiency virus type 1 viral load assays were compared at nine laboratories with different competitor ...pre-m1000 ... See full document

6

Sensitivity of the Procleix HIV 1/HCV Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA in a High Risk Population

Sensitivity of the Procleix HIV 1/HCV Assay for Detection of Human Immunodeficiency Virus Type 1 and Hepatitis C Virus RNA in a High Risk Population

... HIV-1/HCV Assay is a nucleic acid test (NAT) for the simultaneous detection of human immunodeficiency virus type 1 (HIV-1) and hepatitis C ... See full document

5

Automated Multiplex Assay System for Simultaneous Detection of Hepatitis B Virus DNA, Hepatitis C Virus RNA, and Human Immunodeficiency Virus Type 1 RNA

Automated Multiplex Assay System for Simultaneous Detection of Hepatitis B Virus DNA, Hepatitis C Virus RNA, and Human Immunodeficiency Virus Type 1 RNA

... amplification-based multiplex assays (1, 5, 8, 15, 21) have been developed by different laboratories and com- ...a multiplex assay for detecting hepatitis B virus (HBV), ... See full document

9

The development of a GeXP based multiplex reverse transcription PCR assay for simultaneous detection of sixteen human respiratory virus types/subtypes

The development of a GeXP based multiplex reverse transcription PCR assay for simultaneous detection of sixteen human respiratory virus types/subtypes

... RT-PCR assay using the GeXP (GeXP assay) for rapid, sensitive, multiplex detection of sixteen different respiratory virus types/subtypes: influ- enza A virus (FluA), ... See full document

8

Flow cytometric immunofluorescence assay for detection of antibodies to human immunodeficiency virus type 1 using insoluble precursor forms of recombinant polyproteins as carriers and antigens

Flow cytometric immunofluorescence assay for detection of antibodies to human immunodeficiency virus type 1 using insoluble precursor forms of recombinant polyproteins as carriers and antigens

... detect human immunodeficiency virus type 1 (HIV-1) infection since the tests were first licensed in 1985 ...the detection of HIV DNA and RNA by PCR and virus ... See full document

8

Quantitative Detection of Plasma Human Immunodeficiency Virus Type 2 Subtype A RNA by the Nuclisens EasyQ Assay (Version 1 1)

Quantitative Detection of Plasma Human Immunodeficiency Virus Type 2 Subtype A RNA by the Nuclisens EasyQ Assay (Version 1 1)

... The detection limit was set to 200 copies/ml, which might be a little high, particularly since half of the HIV-2-infected clin- ical samples tested were considered to have undetectable vire- ...the assay ... See full document

5

Significant Closure of the Human Immunodeficiency Virus Type 1 and Hepatitis C Virus Preseroconversion Detection Windows with a Transcription Mediated Amplification Driven Assay

Significant Closure of the Human Immunodeficiency Virus Type 1 and Hepatitis C Virus Preseroconversion Detection Windows with a Transcription Mediated Amplification Driven Assay

... HIV-1 RNA detection by PCR was carried out by the vendors of the seroconversion panels by using the Am- plicor HIV-1 monitor kit (Roche Diagnostics, Branchburg, ... See full document

6

Highly Sensitive Methods for Quantitation of Human Immunodeficiency Virus Type 1 RNA from Plasma, Cells, and Tissues

Highly Sensitive Methods for Quantitation of Human Immunodeficiency Virus Type 1 RNA from Plasma, Cells, and Tissues

... cellular RNA purified with RNeasy silica columns was added to the Amplicor test to quantitate HIV-1 RNA from PBMCs and tonsil biopsy ...total RNA. In our hands, up to 2.6 mg of extracted total ... See full document

5

Evaluation of the Abbott LCx HIV 1 RNA Quantitative, a New Assay for Quantitative Determination of Human Immunodeficiency Virus Type 1 RNA

Evaluation of the Abbott LCx HIV 1 RNA Quantitative, a New Assay for Quantitative Determination of Human Immunodeficiency Virus Type 1 RNA

... HIV RNA Quantitative ...the assay controls and clinical samples were ex- tracted by centrifugation and separation using a QIAAmp col- umn and subjected to amplification with primers targeted at a ... See full document

5

Rapid and Sensitive Oligonucleotide Ligation Assay for Detection of Mutations in Human Immunodeficiency Virus Type 1 Associated with High Level Resistance to Protease Inhibitors

Rapid and Sensitive Oligonucleotide Ligation Assay for Detection of Mutations in Human Immunodeficiency Virus Type 1 Associated with High Level Resistance to Protease Inhibitors

... of human immunodeficiency virus type 1 (HIV-1) infec- tion has been an important cause of treatment failure and limits options for alternative antiretroviral ... See full document

7

High Levels of Chronic Immune Activation in the T-Cell Compartments of Patients Coinfected with Hepatitis C Virus and Human Immunodeficiency Virus Type 1 and on Highly Active Antiretroviral Therapy Are Reverted by Alpha Interferon and Ribavirin Treatment

High Levels of Chronic Immune Activation in the T-Cell Compartments of Patients Coinfected with Hepatitis C Virus and Human Immunodeficiency Virus Type 1 and on Highly Active Antiretroviral Therapy Are Reverted by Alpha Interferon and Ribavirin Treatment

... HCV RNA levels were measured using the Cobas TaqMan HCV test with a limit of detection of 15 IU/ml (Roche Diagnostics, Branchburg, ...HCV RNA was undetectable in a majority of the ...the human ... See full document

5

Cancer and Infectious Causes

Cancer and Infectious Causes

... There are several potential mechanisms associated with the development of cholangiocarcinoma from Salmo- nella typhi. The first mechanism is associated with cholangiocarcinoma formation involves the deconjugation of ... See full document

18

Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano gold immunological amplification and silver staining method

Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano gold immunological amplification and silver staining method

... our assay, we applied a versatile precipitation method capable to generate mono-dis- persed, spherical nano-gold particles using aqueous solu- tion of gold chloride and sodium citrate as the reducing ... See full document

8

Blood exposures in surgical practice: incidence, reporting rates, causation and prevention.

Blood exposures in surgical practice: incidence, reporting rates, causation and prevention.

... by suture needles some people have suggested using blunt needles wherever possible, and many surgeons are adopting this instrument. There is convincing evidence for the protective effect of double gloving, but this ... See full document

155

RNA secondary structure and binding sites for gag gene products in the 5' packaging signal of human immunodeficiency virus type 1.

RNA secondary structure and binding sites for gag gene products in the 5' packaging signal of human immunodeficiency virus type 1.

... retroviral RNA requires sequences in the Gag protein, as well as a cis-acting RNA packaging signal ( C site) near the 5 * end of the genomic ...of human immunode- ficiency virus ... See full document

9

Mammalian microRNA: an important modulator of host-pathogen interactions in human viral infections

Mammalian microRNA: an important modulator of host-pathogen interactions in human viral infections

... the virus encoded proteins that counteract against the RNA interference mediated by miRNA or other small ...Ebola virus, tat pro- tein of HIV, Core protein (C) of HCV, nonstructural protein ... See full document

11

Antibody dependent CD56+ T cell responses are functionally impaired in long term HIV 1 infection

Antibody dependent CD56+ T cell responses are functionally impaired in long term HIV 1 infection

... cells [38]. CD56+ T cells were heterozygous cell popula- tion and could be subdivided into CD4+, CD8+, and DN subsets. Interestingly, unlike CD56− T cells, in which CD4+ or CD8+ single positive subset played the domi- ... See full document

17

Evaluation of a Multiple Cycle, Recombinant Virus, Growth Competition Assay That Uses Flow Cytometry To Measure Replication Efficiency of Human Immunodeficiency Virus Type 1 in Cell Culture

Evaluation of a Multiple Cycle, Recombinant Virus, Growth Competition Assay That Uses Flow Cytometry To Measure Replication Efficiency of Human Immunodeficiency Virus Type 1 in Cell Culture

... Competition assay of wild-type ...each virus and dividing it by the sum of the percent infected cells (or the number of infected cells) for both viruses and then multiplying that value by ... See full document

15

Show all 10000 documents...