• No results found

[PDF] Top 20 Multiple extrafoveal macular holes following internal limiting membrane peeling

Has 10000 "Multiple extrafoveal macular holes following internal limiting membrane peeling" found on our website. Below are the top 20 most common "Multiple extrafoveal macular holes following internal limiting membrane peeling".

Multiple extrafoveal macular holes following internal limiting membrane peeling

Multiple extrafoveal macular holes following internal limiting membrane peeling

... Objective: Internal limiting membrane (ILM) peeling has been the standard of treatment for macular ...postoperative extrafoveal multiple retinal holes is a rare ... See full document

7

<p>Optical Coherence Tomography Morphological Features Following Modified Internal Limiting Membrane Surgical Technique In Traumatic Macular Holes</p>

<p>Optical Coherence Tomography Morphological Features Following Modified Internal Limiting Membrane Surgical Technique In Traumatic Macular Holes</p>

... ILM fl ap technique (IFT). We routinely used intravitreal triamcinolone acetonide (IVTA) for identi fi cation of the posterior hyaloid followed by induction of posterior vitr- eous detachment (PVD) by applying active ... See full document

10

Internal limiting membrane peeling versus no peeling for idiopathic full thickness macular hole : a pragmatic randomized controlled trial

Internal limiting membrane peeling versus no peeling for idiopathic full thickness macular hole : a pragmatic randomized controlled trial

... stated in this published protocol, in addition to the above, in all participating centres colour photographs and red free images were obtained at each time point (baseline, 1, 3 and 6 months) and evaluated, in a masked ... See full document

27

Outcomes of 23-gauge pars plana vitrectomy and internal limiting membrane peeling with brilliant blue in macular hole

Outcomes of 23-gauge pars plana vitrectomy and internal limiting membrane peeling with brilliant blue in macular hole

... 4 macular holes according to Gass Classi- fication who had undergone PPV and ILM peeling were included in this ...operative macular examinations were assessed with spectral-domain optical ... See full document

7

&lt;p&gt;Evaluation of Vision-Related Quality of Life after Autologous Internal Limiting&amp;ndash;Membrane Transplantation for Refractory Macular Holes&lt;/p&gt;

<p>Evaluation of Vision-Related Quality of Life after Autologous Internal Limiting&ndash;Membrane Transplantation for Refractory Macular Holes</p>

... ILM peeling for refractory MHs might be ineffective for anatomical reduction, owing to the complicated pathological structure and/or complications (such as choroidal atrophy, retinoschisis, traumatic choroidal ... See full document

7

Clinical and cost effectiveness of internal limiting membrane peeling for patients with idiopathic full thickness macular hole  Protocol for a Randomised Controlled Trial: FILMS (Full thickness macular hole and Internal Limiting Membrane peeling Study)

Clinical and cost effectiveness of internal limiting membrane peeling for patients with idiopathic full thickness macular hole Protocol for a Randomised Controlled Trial: FILMS (Full thickness macular hole and Internal Limiting Membrane peeling Study)

... ILM peeling in the nerve fibre layer of the retina, which potentially could have adverse effects on central vision ...ILM peeling in FTMH surgery for stage 2–3 ...ILM peeling in all cases, whereas ... See full document

8

Primary silicone oil tamponade and internal limiting membrane peeling for retinal detachment due to macular hole in highly myopic eyes with chorioretinal atrophy

Primary silicone oil tamponade and internal limiting membrane peeling for retinal detachment due to macular hole in highly myopic eyes with chorioretinal atrophy

... the following findings in fundus features: (1) a PCA within the vascular arcade or restricted to the posterior pole or (2) a PCA also extending beyond the vascular ... See full document

7

Comparative study of inverted internal limiting membrane (ILM) flap and ILM peeling technique in large macular holes: a randomized-control trial

Comparative study of inverted internal limiting membrane (ILM) flap and ILM peeling technique in large macular holes: a randomized-control trial

... of macular hole with resolution of subretinal cuff of fluid and neurosensory retina (NSR) completely covering the fovea ...the macular hole was attached to the underlying retinal pigment epithelium (RPE) ... See full document

6

Fovea sparing internal limiting membrane peeling using multiple parafoveal curvilinear peels for myopic foveoschisis: technique and outcome

Fovea sparing internal limiting membrane peeling using multiple parafoveal curvilinear peels for myopic foveoschisis: technique and outcome

... ILM peeling is a widely-performed technique to manage idiopathic MH and myopic traction ...ILM peeling results in long-term favorable anatomical and visual outcomes [4–6], However, there have been ... See full document

5

Retinal thickness after vitrectomy and internal limiting membrane peeling for macular hole and epiretinal membrane

Retinal thickness after vitrectomy and internal limiting membrane peeling for macular hole and epiretinal membrane

... ILM peeling, for bilateral macular holes are shown in Figures 1 and ...different macular features between ILM-peeled and non-ILM-peeled groups; there were some deep dimples mainly in the ... See full document

10

Virtual retinectomy: indocyanine green-assisted internal limiting membrane peeling as a surgical adjunct in repair of recurrent rhegmatogenous retinal detachment due to PVR

Virtual retinectomy: indocyanine green-assisted internal limiting membrane peeling as a surgical adjunct in repair of recurrent rhegmatogenous retinal detachment due to PVR

... Only recurrent rhegmatogenous retinal detachments which were PVR-related were considered for the review. Primary retinal detachments, eyes with proliferative or tractional diabetic disease, staphylomatous detachments, ... See full document

6

Pars plana vitrectomy and internal limiting membrane peeling for macular edema secondary to retinal vein occlusion

Pars plana vitrectomy and internal limiting membrane peeling for macular edema secondary to retinal vein occlusion

... ILM peeling can be one method for decreasing ME due to RVO but, because of the multiple possible causes for decreased VA in RVO (such as photoreceptor ischemia and atrophy), it is suggested that a larger ... See full document

5

Assessment of macular function by multifocal electroretinography following epiretinal membrane surgery with internal limiting membrane peeling

Assessment of macular function by multifocal electroretinography following epiretinal membrane surgery with internal limiting membrane peeling

... All patients underwent a thorough ophthalmologic examination at baseline. Best-corrected visual acuity (VA), optical coherence tomography (OCT) (Cirrus SD high- definition OCT; Carl Zeiss Meditec AG, Jena, Germany), and ... See full document

6

Transconjunctival 25-gauge pars plana vitrectomy and internal limiting membrane peeling for chronic macular edema

Transconjunctival 25-gauge pars plana vitrectomy and internal limiting membrane peeling for chronic macular edema

... improved macular edema had improvement in vision. This may be related to multiple factors, such as the chronicity of macular edema (19 months in duration on aver- age in our study) resulting in ... See full document

9

Vitrectomy with internal limiting membrane peeling versus inverted internal limiting membrane flap technique for macular hole-induced retinal detachment: a systematic review of literature and meta-analysis

Vitrectomy with internal limiting membrane peeling versus inverted internal limiting membrane flap technique for macular hole-induced retinal detachment: a systematic review of literature and meta-analysis

... the macular hole, the rate of retinal reattach- ment and the macular hole closure were significantly higher in the inverted ILM flap technique group(p = ...the macular hole to cover the surface of ... See full document

11

Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling

Endoilluminator phototoxic maculopathy associated with combined ICG-assisted epiretinal membrane and internal limiting membrane peeling

... Approximately 0.1 mL of ICG 0.2% is applied under fluid before being immediately removed. ICG is reapplied once after ERM peeling to stain residual ILM. The ILM rhexis is initiated with a vertical incision ... See full document

6

Comparisons of foveal thickness and slope after macular hole surgery with and without internal limiting membrane peeling

Comparisons of foveal thickness and slope after macular hole surgery with and without internal limiting membrane peeling

... ILM peeling than in eyes with ILM ...ILM peeling group, the mean parafoveal thickness in the nasal sector was significantly higher than that in other ... See full document

8

Increase in average foveal thickness after internal limiting membrane peeling

Increase in average foveal thickness after internal limiting membrane peeling

... The retinal surface maps were reconstructed from the three-dimensional cube scans, and the macular cube scans were used to measure the average foveal thickness. The central and the inner four sectors as defined by ... See full document

7

Outcomes of microincision vitrectomy surgery with internal limiting membrane peeling for macular edema secondary to branch retinal vein occlusion

Outcomes of microincision vitrectomy surgery with internal limiting membrane peeling for macular edema secondary to branch retinal vein occlusion

... of macular edema was determined if CFT was ...rent macular edema deemed to be affecting the patient’s visual acuity according to the investigator’s ... See full document

6

Internal limiting membrane peeling and gas tamponade for myopic foveoschisis: a systematic review and meta-analysis

Internal limiting membrane peeling and gas tamponade for myopic foveoschisis: a systematic review and meta-analysis

... ILM peeling group versus that of non-ILM peeling group, and the validity and safety of Tamponade group versus that of non-Tamponade group for the treatment of ...ILM peeling could contribute to ... See full document

10

Show all 10000 documents...