• No results found

AE signals

Characterization of AE Signals Generated by Gas Leak on Pipe with Artificial Defect at Different Wall Thickness

Characterization of AE Signals Generated by Gas Leak on Pipe with Artificial Defect at Different Wall Thickness

... different AE signals generated from the gas leakage and eventually could enhance in the analysis of defect development during actual monitor- ing and inspection of ...the AE signals generated ...

6

Detection of Acoustic Emission Characteristics of Plant According to Water Stress Condition

Detection of Acoustic Emission Characteristics of Plant According to Water Stress Condition

... the AE signal outcomes of the experiment can be presented by line graphs in ...of AE parameters (RMS and counts number) detected from both plants and air temperature, light intensity and relative humidity ...

7

Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring

Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring

... Background: This study investigated the biomechanical interactions in endodonti‑ cally treated tooth implant‑supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the ...

10

FFT analysis of ball bearing faults using AE

FFT analysis of ball bearing faults using AE

... domain AE signals and the corresponding frequency spectrum for several test replications are ...of AE signals are of high values that rises up to ...

6

Filtering of Acoustic Emission Signals for the Accurate Identification of Fracture Mechanisms in Bending Tests

Filtering of Acoustic Emission Signals for the Accurate Identification of Fracture Mechanisms in Bending Tests

... the AE signals which are emitted by (i) residual environmental noise (measurement chain noises) and (ii) AE signals related with the contact between supports and the specimen (mechanical ...

8

Pattern recognition of acoustic emission signal during the mode I fracture mechanisms in carbon- epoxy composite

Pattern recognition of acoustic emission signal during the mode I fracture mechanisms in carbon- epoxy composite

... (AE) signals are the ultrasonic waves (ultrasonic) that are produced when the material undergoes to the ...the signals from different sources of acoustic emission and failure ...

13

Estimation of Stress Corrosion Cracking Initiation and Propagation in High Pressure, High Temperature Water Environment Utilizing Acoustic Emission

Estimation of Stress Corrosion Cracking Initiation and Propagation in High Pressure, High Temperature Water Environment Utilizing Acoustic Emission

... The creviced bent beam (CBB) test 6,7) is an accelerated laboratory test that is used to evaluate SCC initiation in high- temperature and high-pressure water environments, but does not allow for the detection of SCC ...

6

Mathematical Model and Regression Analysis of Acoustic Emission Signals Generated by Partial Discharges

Mathematical Model and Regression Analysis of Acoustic Emission Signals Generated by Partial Discharges

... of AE signals registered in experiments performed under laboratory conditions, while changing the setup for particular insulation defects induced by ...registered signals. 480 selected AE ...

6

Evaluation of Corrosion Critical Variables of 304 Stainless Steel by Delay Time of Acoustic Emission

Evaluation of Corrosion Critical Variables of 304 Stainless Steel by Delay Time of Acoustic Emission

... with a gas pressure threshold for hydrogen bubbles to break- up at the counter electrode. The resulting acoustic pulse emission is again related with the metal dissolution according to the oxidation reaction of eq. (2). ...

6

Damage Classification of Sandwich Composites Using Acoustic Emission Technique and k means Genetic Algorithm

Damage Classification of Sandwich Composites Using Acoustic Emission Technique and k means Genetic Algorithm

... PCA is a multivariate analysis tool usually used to reduce dimensionality of a large data set to enable better visualization and analysis of data [27]. With the aim of dimensional reduction, the data is transformed to a ...

31

Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing

Examination of ceramic restoration adhesive coverage in cusp-replacement premolar using acoustic emission under fatigue testing

... of AE signals under normal occlusal force (200 N) in the fatigue test were found between with and without buccal cuspal coverage ...first AE activity occurring for the WOC restoration was lower than ...

11

Effects of fuel cladding surface states on the crud deposition in simulated primary water of pwrs

Effects of fuel cladding surface states on the crud deposition in simulated primary water of pwrs

... An AE sensor was coupled to the upper end of the cladding tube, as shown in Figures 1 and ...the AE signal attenuation, we used the cladding tube with the same dimension and geometry equipped to an ...

10

Cluster Analysis of Acoustic Emissions Measured during Deformation of Duplex Stainless Steels

Cluster Analysis of Acoustic Emissions Measured during Deformation of Duplex Stainless Steels

... (AE) signals which arise during plastic deformation of materials offers a clue for the investigation of micro- structural processes and their kinetics in real time scale and is therefore used as a primary ...

8

Acoustic Emission Pattern Recognition Method Utilizing Elastic Wave Simulation

Acoustic Emission Pattern Recognition Method Utilizing Elastic Wave Simulation

... from AE source to the AE sensor directly but also reflected from edge of ...detected AE signal is classified for simulation fracture type A with a high agree- ment ...

7

Acoustic Emission of Hydrogen Bubbles on the Counter Electrode during Pitting Corrosion of 304 Stainless Steel

Acoustic Emission of Hydrogen Bubbles on the Counter Electrode during Pitting Corrosion of 304 Stainless Steel

... cumulative AE counts were divided into three distinct stages showing their own unique behavior in terms of rise time and ...of AE signal. In the AE Stage III, the cumulative counts of the AE ...

6

Relationship between the movements of the mouthparts of the bamboo powder-post beetle Dinoderus minutus and the generation of acoustic emission

Relationship between the movements of the mouthparts of the bamboo powder-post beetle Dinoderus minutus and the generation of acoustic emission

... the AE sensor (R15a, Physical Acoustics ...the AE detection of insects [5–11, 14, ...an AE tester (AE9501A, NF ...The AE signals from the sensor were ampli- fied by 40 times and ...

8

AE ). The changes in cutting condition

AE ). The changes in cutting condition

... possible AE sources referring to stress waves generated by the sudden release of energy in deforming material during metal cutting are: (a) plastic deformation of the workpiece during cutting process, (b) sharing ...

5

Damage Evaluation in Lithium Cobalt Oxide/Carbon Electrodes of Secondary Battery by Acoustic Emission Monitoring

Damage Evaluation in Lithium Cobalt Oxide/Carbon Electrodes of Secondary Battery by Acoustic Emission Monitoring

... of AE signals were successfully detected during charge / ...detected AE signals were classi fi ed into two distinct types ...the AE waveform parameters ...2 signals with long ...

5

Evaluation of Thermal Deformation Process of Nickel Based Active Composites by Laser AE Technique

Evaluation of Thermal Deformation Process of Nickel Based Active Composites by Laser AE Technique

... A-type signals are identified to be crack propagation and the peak frequency in the B-type and C-type is due to the ...in signals could not be detected, because the laser AE has a low pass filter (LPF) ...

7

The Measurement of Acoustic Emission Signals from Stem of Maize Under Controlled Environment

The Measurement of Acoustic Emission Signals from Stem of Maize Under Controlled Environment

... system. AE signals from stem of investigated maize being under well watered condition throughout experiment is investigated with acoustic emission parameters evaluating unit of XEDO-AE system and ...

7

Show all 6671 documents...

Related subjects