• No results found

Cathodic Stripping Voltammetry

Study on Heparin Determination Using Cathodic Stripping Voltammetry

Study on Heparin Determination Using Cathodic Stripping Voltammetry

... Quantitative measurements were performed using differential pulse cathodic stripping voltammetry (DP CSV) with the standard addition procedure and were carried out in the supporting electrolyte: ...

11

Electrochemical and chromatographic studies of clopidogrel using cathodic stripping voltammetry and HPLC under new experimental conditions and its determination in the preparation tablet, urine and plasma samples

Electrochemical and chromatographic studies of clopidogrel using cathodic stripping voltammetry and HPLC under new experimental conditions and its determination in the preparation tablet, urine and plasma samples

... a cathodic stripping voltammetry technique in the carbonate buffer pH 10 on a surface of hanging mercury drop working electrode (HMDE) ν s Ag/AgCl reference electrode and Pt auxiliary ...of ...

8

Application of Nitrilotriacetic Acid Modified Gold Electrode for Determination of Lead in Natural Waters with Differential Pulse Adsorptive Cathodic Stripping Voltammetry

Application of Nitrilotriacetic Acid Modified Gold Electrode for Determination of Lead in Natural Waters with Differential Pulse Adsorptive Cathodic Stripping Voltammetry

... cyclic voltammetry and electrochemical impedance spectroscopy in the presence of potassium ...adsorptive cathodic stripping ...and stripping solutions) the dependence of the stripping ...

14

Determination of optimal conditions for the dosage of selenium in whole human blood by differential pulse cathodic stripping voltammetry

Determination of optimal conditions for the dosage of selenium in whole human blood by differential pulse cathodic stripping voltammetry

... The objective is the determination of the conditions operating optimal to determine the concentration of the selenium dissolved in the human blood. An electroanalytical method has been developed for the determination of ...

6

Analysis of selenium species using cathodic stripping voltammetry

Analysis of selenium species using cathodic stripping voltammetry

... pulse cathodic stripping voltammetry of an inorganic selenium (selenite, Se(IV)) and organic selenium (dimethyl diselenide, DMDSe) was investigated using hanging mercury drop electrode ...

12

Determination of Trace Amounts of Bismuth In Pharmaceutical and Water by Adsorptive Cathodic Stripping Voltammetry in the Presence of Xylenol Orange

Determination of Trace Amounts of Bismuth In Pharmaceutical and Water by Adsorptive Cathodic Stripping Voltammetry in the Presence of Xylenol Orange

... years, stripping voltammetry techniques, particularly anodic and adsorptive cathodic stripping voltammetr y, have shown numerous advantages, including speed of analysis, good selectivity and ...

7

Electrochemical behaviour of pesticides at bare and nylon 6,6-modified solid electrodes in differential pulse cathodic stripping voltammetry

Electrochemical behaviour of pesticides at bare and nylon 6,6-modified solid electrodes in differential pulse cathodic stripping voltammetry

... hand, voltammetry technique offers advantages for pesticides determinations such as simplicity, high sensitivity and easy ...Besides, stripping techniques are usually accredited due to the exceptional ...

71

“Electrochemical Analysis Techniques: A Review on Recent Pharmaceutical Applications” by O. A. Farghaly, R. S. Abdel Hameed, Abd-Alhakeem H. Abu-Nawwas, Egypt.

“Electrochemical Analysis Techniques: A Review on Recent Pharmaceutical Applications” by O. A. Farghaly, R. S. Abdel Hameed, Abd-Alhakeem H. Abu-Nawwas, Egypt.

... adsorptive cathodic differential pulse stripping voltammetry with the HMDE 79 ...Adsorptive cathodic stripping voltammetry is used for the determination of trace levels of ...

9

Electroanalytical studies of aflatoxins - stripping voltammetric methods for the determination of aflatoxin compounds

Electroanalytical studies of aflatoxins - stripping voltammetric methods for the determination of aflatoxin compounds

... Aflatoxin, which is produced by Aspergillus flavus and Aspergillus parasiticus fungi is one of the compounds in the mycotoxin group. The main types of aflatoxins are AFB1, AFB2, AFG1 and AFG2 which have carcinogenic ...

718

Adsorptive Cathodic Stripping Voltammetric  Method with Alizarin for the Simultaneous Determination of Cadmium, and Zinc in Water Samples

Adsorptive Cathodic Stripping Voltammetric Method with Alizarin for the Simultaneous Determination of Cadmium, and Zinc in Water Samples

... Adsorptive cathodic stripping voltammetry (AdCSV) was selected as such a method, because it has the advantage of a linear dynamic range of 4-5 orders of magnitude, the limit of detection ng/L to ...

10

Reduction Charge Smaller than the Deposited One in Cathodic Stripping Voltammograms of AgCl

Reduction Charge Smaller than the Deposited One in Cathodic Stripping Voltammograms of AgCl

... the scanned potential for the deposited silver can oxidize the silver atoms at any location so far as they have electric connection to the electrode. In contrast, the reduction of an AgCl molecule in cathodic ...

10

Chemical speciation of iron with humic ligands in estuarine and coastal waters

Chemical speciation of iron with humic ligands in estuarine and coastal waters

... Determination of complexation of iron III with natural organic complexing ligands in seawater using cathodic stripping voltammetry.. Spatial and temporal variability in nutrient concentr[r] ...

184

Adsorptive Stripping Voltammetry for Determination of Cadmium in the presence of Cupferron on a Nafion-coated Bismuth Film Electrode

Adsorptive Stripping Voltammetry for Determination of Cadmium in the presence of Cupferron on a Nafion-coated Bismuth Film Electrode

... adsorptive cathodic stripping voltammetry was ...subsequent stripping from the electrode by square wave cathodic voltammetric and the reduction of Cd-cupferron ...

10

Highly Sensitive EQCM Sensor for Mercury Determination by Coupled Stripping Voltammetry

Highly Sensitive EQCM Sensor for Mercury Determination by Coupled Stripping Voltammetry

... anodic stripping voltammetry (ASV), anodic stripping peaks observed in the range ...single stripping peak was observed at approximately ...mercury stripping potential was observed at ...

11

A Hyphenation of Stripping Voltammetry with Electrospray Ionization Mass Spectrometry; an Effect of Sodium Perchlorate on Ferrocene Oxidation

A Hyphenation of Stripping Voltammetry with Electrospray Ionization Mass Spectrometry; an Effect of Sodium Perchlorate on Ferrocene Oxidation

... Differential pulse anodic stripping voltammetry (DPASV) was realized in different accumulation potentials (Fig. 5b) to see the impact of the value of inserted potential. Because oxidation of ferrocene is ...

12

Study of trace metals in natural water using anodic stripping voltammetry

Study of trace metals in natural water using anodic stripping voltammetry

... Study of trace metals in natural water using anodic stripping voltammetry.. Available from Sheffield Hallam University Research Archive SHURA at: http://shura.shu.ac.uk/19356/.[r] ...

192

Quantification of Sub-Nanomolar Levels of Gallic Acid by Adsorptive Stripping Voltammetry

Quantification of Sub-Nanomolar Levels of Gallic Acid by Adsorptive Stripping Voltammetry

... The paper showed that adsorptive stripping voltammetry is a useful method for the highly sensitive and selective determination of GA. The proposed procedure is simple and inexpensive, also is more sensitive ...

10

Assay of Nimodipine - an Anti Hypertensive drug, in Bulk Form and Pharmaceutical Formulations by Cathodic Adsorptive Stripping Voltammetry

Assay of Nimodipine - an Anti Hypertensive drug, in Bulk Form and Pharmaceutical Formulations by Cathodic Adsorptive Stripping Voltammetry

... The square-wave cathodic adsorptive stripping peak height for 1.5x10 -4 mol L -1 nimodipine depends strongly on accumulation time suggesting an effective adsorption of nimodipine on the HMDE. The effect of ...

15

Determination of Au(III) and Ag(I) in Carbonaceous

Determination of Au(III) and Ag(I) in Carbonaceous

... at al Anodic stripping voltammetry of silver(I) using a carbon paste electrode 385. modified with multi-walled carbon nanotubes[r] ...

13

Abrasive Stripping Square Wave Voltammetry of Some Natural Antioxidants

Abrasive Stripping Square Wave Voltammetry of Some Natural Antioxidants

... Sci., 11 2016 836 - 842 International Journal of ELECTROCHEMICAL SCIENCE www.electrochemsci.org Abrasive Stripping Square Wave Voltammetry of Some Natural Antioxidants Šebojka Komorsky-L[r] ...

7

Show all 1172 documents...

Related subjects